Puglla Puglla, Yomaira Alejandra(Universitat Politècnica de València, 2024-06-17)
[ES] La Estación de Depuración de Aguas Residuales (EDAR) de Santa Pola Alicante recoge y trata las aguas de la población Santa Pola y Gran Alacant. El sistema de trasporte de aguas residuales de Santa Pola ha alcanzado ...
The aim of this study was to assess the effect of several operational variables on both biological and separation process performance in a submerged anaerobic membrane bioreactor pilot plant that treats urban wastewater. ...
Barredo Damas, Sergio; Alcaina Miranda, María Isabel; GEMMA, MATTEO; Iborra Clar, María Isabel; Mendoza Roca, José Antonio(IWA Publishing, 2011)
[EN] This work studies the performance of three commercial ceramic ultrafiltration membranes (ZrO 2-TiO 2) treating raw effluent from a textile industry. The effect of crossflow velocity at 3, 4 and 5 m s -1 as well as ...
The paper expresses an attempt to tackle the problem due to the presence of micropollutants in wastewater which may be able to disrupt the endocrine system of some organisms. These kinds of compounds are ubiquitously present ...
The biologically induced precipitation processes can be important in wastewater treatment, in particular treating raw wastewater with high calcium concentration combined with Enhanced Biological Phosphorus Removal. Currently, ...
Several methods to detect faults have been developed in various fields, mainly in chemical and process engineering. However, minimal practical guidelines exist for their selection and application. This work presents an ...
Robles Martínez, Ángel; Ruano García, María Victoria; García Usach, Mª Francisca; FERRER, J.(Elsevier, 2012-06)
A submerged anaerobic MBR demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON®, Koch Membrane Systems, PUR-PSH31) was operated using municipal wastewater at high levels of mixed liquor total ...