[EN] Bearings are the elements that allow the rotatory movement in induction motors and the fault occurrence in these elements are due to excessive working conditions. In induction motors, elec-trical erosion remains the ...
Muhammad Faizan Shaikh; Park, Jongsan; Park, Yonghyun; Antonino-Daviu, J.; Lee, Sang Bin(Institute of Electrical and Electronics Engineers, 2022-07)
[EN] Broken damper bars and shorted field winding
turns degrade the starting and running performance of
industrial wound field synchronous motors (WFSMs), and can
lead to a forced outage of the motor and driven process. ...
García Moreno, Emilio; Correcher Salvador, Antonio; Quiles Cucarella, Eduardo; Morant Anglada, Francisco José(Universitat Politecnica de Valencia, 2016)
[ES] En este artículo se presentan una serie de dispositivos generadores de energía renovable procedente del entorno marino, que en