dc.description.abstract | [ES] En el proyecto que se desarrolla a continuación se expone el cálculo y diseño de la instalación de climatización del Colegio Público Lluis Vives de Bocairent. El centro educativo se ubica en la calle José Puig, 8, 46880 Bocairent, València. Se ha llevado a cabo realizando el cálculo de las cargas térmicas de cada local climatizable empleado el programa vp_clima, también siguiendo el código técnico, las normativas pertinentes y empleando los conocimientos adquiridos a lo largo del grado. Para finalizar se han seleccionado los equipos de los que estará compuesta la instalación, y se ha dimensionado la red de tuberías de agua con diámetros comerciales. | es_ES |
dc.description.abstract | [CA] En el projecte que es desenvolupa a continuació s'exposa el càlcul i disseny de l’instal·lació de climatització del Col·legi Públic Lluís Vives de Bocairent. El centre educatiu s'ubica al carrer José Puig, 8, 46880 Bocairent, València. S'ha dut a terme realitzant el càlcul de les càrregues tèrmiques de cada local climatizable emprat el programa vp_clima, també seguint el codi tècnic, les normatives pertinents i emprant els coneixements adquirits al llarg del grau. Per finalitzar, s'han seleccionat els equips dels que estarà composta la instal·lació, i es s'ha dimensionat la xarxa de canonades d'aigua amb diàmetres comercials. | es_ES |
dc.description.abstract | [EN] In the project developed below, the calculation and design of the air conditioning installation of the Lluis Vives de Bocairent Public School is presented. The educational center is located at José Puig Street, 8, 46880 Bocairent, València. It has been carried out by calculating the thermal loads of each climatisable room used in the vp_clima program, also following the technical code, the pertinent regulations and using the knowledge acquired throughout the degree. Finally, the teams of which the installation will be composed have been selected, and the network of water pipes with commercial diameters has been dimensioned. | es_ES |
dc.format.extent | 141 | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Climatización | es_ES |
dc.subject | Bomba de Calor | es_ES |
dc.subject | Ventilo-convectores. | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.subject.other | Grado en Ingeniería Mecánica-Grau en Enginyeria Mecànica | es_ES |
dc.title | Diseño de instalacion de climatizacion del CEIP Lluis Vives de Bocairent | es_ES |
dc.type | Proyecto/Trabajo fin de carrera/grado | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny | es_ES |
dc.description.bibliographicCitation | Calabuig Belda, J. (2019). Diseño de instalacion de climatizacion del CEIP Lluis Vives de Bocairent. Universitat Politècnica de València. http://hdl.handle.net/10251/126291 | es_ES |
dc.description.accrualMethod | TFGM | es_ES |
dc.relation.pasarela | TFGM\108806 | es_ES |