Análisis termodinámico y optimización de un ciclo de refrigeración solar en cascada

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Análisis termodinámico y optimización de un ciclo de refrigeración solar en cascada

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Dolz Ruiz, Vicente es_ES
dc.contributor.author Romero Huedo, Miquel Ferran es_ES
dc.date.accessioned 2021-09-07T10:29:22Z
dc.date.available 2021-09-07T10:29:22Z
dc.date.created 2021-07-28
dc.date.issued 2021-09-07 es_ES
dc.identifier.uri http://hdl.handle.net/10251/171593
dc.description.abstract [ES] El presente trabajo consiste en el estudio de viabilidad de un ciclo de refrigeración solar formado por un ciclo de eyección y un ciclo de refrigeración convencional acoplados en cascada para su aplicación en un sistema de aire acondicionado. El ciclo de eyección es capaz de generar una determinada capacidad de refrigeración empleando una fuente de calor residual, en este caso la energía solar térmica. Gracias a este sistema, el ciclo de refrigeración convencional puede operar frente a presiones de condensación menores y por lo tanto se reduce la carga de trabajo del compresor. La recolección de la energía solar térmica se realiza mediante un sistema de colectores solares que se encuentran directamente acoplados al generador del ciclo de eyección. En el trabajo se lleva a cabo el modelado y la optimización del ciclo de refrigeración especial mencionado, basado en el acoplamiento del ciclo de eyección y el ciclo de refrigeración convencional y en la integración del sistema de recolección de energía solar térmica, compuesto por colectores solares de placa plana (CPP), implementado en un circuito con generador. El eyector constituye el elemento clave en el ciclo de eyección para que el sistema sea capaz de operar de forma eficiente. Por este motivo, esta pieza se diseña, se analiza y se optimiza mediante software de cálculo de fluidos computacional. A partir del modelo del ciclo optimizado, se realizan estudios basados en el análisis de la operatividad del mismo en diferentes puntos de funcionamiento y se extraen conclusiones basadas en su viabilidad y su efectividad frente a un sistema de aire acondicionado convencional. es_ES
dc.description.abstract [EN] The present work consists of the feasibility study of a solar refrigeration cycle formed by an ejection cycle and a conventional refrigeration cycle coupled in cascade for their application in an air conditioning system. The ejection cycle is capable of generating a certain cooling capacity using a residual heat source, in this case solar thermal energy. Thanks to this system, the conventional refrigeration cycle can operate against lower condensing pressures and therefore the compressor workload is reduced. The collection of solar thermal energy is carried out by means of a system of solar collectors that are directly coupled to the generator of the ejection cycle. In the work, the modeling and optimization of the aforementioned special refrigeration cycle is carried out, based on the coupling of the ejection cycle and the conventional refrigeration cycle and on the integration of the solar thermal energy collection system, composed of solar flat plate collectors (FPC), implemented in a circuit with generator. The ejector is the key element in the ejection cycle for the system to be able to operate efficiently. For this reason, this piece is designed and analyzed using computational fluid dynamics and is optimized by applying computational techniques. Based on the optimized cycle model, studies are carried out based on the analysis of its operability at different operating points and conclusions are drawn based on its viability and effectiveness compared to a conventional air conditioning system. es_ES
dc.format.extent 141 es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Refrigeración de bajo impacto ambiental es_ES
dc.subject Refrigeración solar es_ES
dc.subject Ciclos de eyección es_ES
dc.subject Recuperación de calor residual es_ES
dc.subject Generación Termosolar es_ES
dc.subject Low environmental impact refrigeration es_ES
dc.subject Solar cooling es_ES
dc.subject Ejection cycles es_ES
dc.subject Recovery of residual heat es_ES
dc.subject Solar thermal Generation es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.subject.other Máster Universitario en Ingeniería Aeronáutica-Màster Universitari en Enginyeria Aeronàutica es_ES
dc.title Análisis termodinámico y optimización de un ciclo de refrigeración solar en cascada es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Máquinas y Motores Térmicos - Departament de Màquines i Motors Tèrmics es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny es_ES
dc.description.bibliographicCitation Romero Huedo, MF. (2021). Análisis termodinámico y optimización de un ciclo de refrigeración solar en cascada. Universitat Politècnica de València. http://hdl.handle.net/10251/171593 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\134410 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem