Simulations and experimental study to compare the behavior of a genset running on gasoline or syngas for small scale power generation

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Simulations and experimental study to compare the behavior of a genset running on gasoline or syngas for small scale power generation

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Vargas-Salgado, Carlos es_ES
dc.contributor.author Águila-León, Jesús es_ES
dc.contributor.author Alfonso-Solar, David es_ES
dc.contributor.author Malmquist, Anders es_ES
dc.date.accessioned 2022-03-22T19:02:34Z
dc.date.available 2022-03-22T19:02:34Z
dc.date.issued 2022-04-01 es_ES
dc.identifier.issn 0360-5442 es_ES
dc.identifier.uri http://hdl.handle.net/10251/181505
dc.description.abstract [EN] Syngas produced from small-scale biomass gasification plants (tens of kW) can generate power from biomass resources. However, due to the syngas gensets demand is marginal, compared to gasoline gensets, it is not easy to find a genset specially designed to run on syngas. In this paper, an experimental study of a genset running on two kinds of fuel has been carried out. The genset used is a 10 kW ICE initially designed to run on gasoline, in parallel, simulations based on CHEMKIN-PRO software were made. The study focuses on the comparison of the ICE operation independently working on gasoline and syngas. Modifications were required in the genset to adapt the intake system to run on syngas. The syngas is obtained from a gasifier. According to the test, it is possible to convert a gasoline engine to a 100% syngas engine through straightforward modifications in the inlet manifold but reducing the efficiency and power. The electrical power running the genset on gasoline was 6.7 kW, whereas, with syngas, it is 4.8 kW (31.4% of reduction). The efficiency running the ICE on gasoline was 13.7% at its rated power, whereas for the genset fuelled on syngas, it was 10.5% (23.4% reduction). es_ES
dc.description.sponsorship This work was completed in the framework of the activities of the Renewable Area research group of the Instituto Universitario de Investigacion en Ingeniería Energética (IUIIE) of Universitat Politecnica de Valencia and by the project "Microred Inteligente Híbrida de Energías Renovables para solucionar el Trilema AguaAlimentacion-Energía en una comunidad rural de Honduras (Task ID 2020_ACDE_000306) es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Energy es_ES
dc.rights Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) es_ES
dc.subject Syngas es_ES
dc.subject Gasoline es_ES
dc.subject Genset es_ES
dc.subject Power Generation es_ES
dc.title Simulations and experimental study to compare the behavior of a genset running on gasoline or syngas for small scale power generation es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.energy.2021.122633 es_ES
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Vargas-Salgado, C.; Águila-León, J.; Alfonso-Solar, D.; Malmquist, A. (2022). Simulations and experimental study to compare the behavior of a genset running on gasoline or syngas for small scale power generation. Energy. 244(Part A):1-19. https://doi.org/10.1016/j.energy.2021.122633 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.energy.2021.122633 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 19 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 244 es_ES
dc.description.issue Part A es_ES
dc.relation.pasarela S\451727 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem