El transporte de agua a presión y su certificación energética. La herramienta ENERGOS

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

El transporte de agua a presión y su certificación energética. La herramienta ENERGOS

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Cabrera, Enrique es_ES
dc.contributor.author Ortiz, Miguel es_ES
dc.contributor.author Gómez, Elena es_ES
dc.contributor.author Maximino, Pascual es_ES
dc.contributor.author del Teso, Roberto es_ES
dc.contributor.author Marco, Carlos es_ES
dc.date.accessioned 2023-02-08T08:08:13Z
dc.date.available 2023-02-08T08:08:13Z
dc.date.issued 2023-01-31
dc.identifier.issn 1134-2196
dc.identifier.uri http://hdl.handle.net/10251/191704
dc.description.abstract [EN] This paper analyses the energy performance of simple pressurised water transport systems, in which a pipe transfers water from the point of origin to the end. The aim of the analysis is to evaluate the energy efficiency of the system and, on this basis, to formulate a proposal for energy certification. To do this, three representative values of the energy intensity indicator Ie, (kWh/m3) are calculated: the ideal energy intensity Iei; the real energy intensity Ier, the quotient between the energy actually consumed (kWh) and the volume transferred (m3) in the same period of time; and, finally, the target energy intensity, Ieo, the unit energy value assuming optimal real operation. The result of the Ier/Ieo quotient summarises the margin for improvement of the system and is therefore used to qualify its energy efficiency. The work concludes with a real example that reproduces the established procedure. es_ES
dc.description.abstract [ES] El presente trabajo analiza el comportamiento energético de los sistemas de transporte de agua a presión simples, en los que una tubería trasiega agua desde el punto origen hasta el final. El objetivo del análisis es evaluar la eficiencia energética del sistema y, a partir de ella, formular una propuesta de certificación energética. Para ello, se calculan tres valores representativos del indicador intensidad energética Ie, (kWh/m3): la intensidad energética ideal Iei; la Intensidad energética real Ier, cociente entre la energía realmente consumida (kWh) y el volumen trasegado (m3) en idéntico periodo de tiempo, y, por último, la Intensidad energética objetivo, Ieo, valor de la energía unitaria suponiendo un funcionamiento real óptimo. El resultado del cociente Ier/Ieo sintetiza el margen de mejora del sistema y, por tanto, es el utilizado para calificar su eficiencia energética. El trabajo concluye con un ejemplo real que reproduce el procedimiento establecido. es_ES
dc.language Español es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.relation.ispartof Ingeniería del Agua es_ES
dc.rights Reconocimiento - No comercial - Compartir igual (by-nc-sa) es_ES
dc.subject Pressure management es_ES
dc.subject Network design es_ES
dc.subject Environmental sustainability es_ES
dc.subject Energy efficiency es_ES
dc.subject Energy intensity es_ES
dc.subject Water and energy es_ES
dc.subject Agua y energía es_ES
dc.subject Gestión de la presión es_ES
dc.subject Diseño de redes es_ES
dc.subject Sostenibilidad ambiental es_ES
dc.subject Eficiencia energética es_ES
dc.subject Intensidad energética es_ES
dc.title El transporte de agua a presión y su certificación energética. La herramienta ENERGOS es_ES
dc.title.alternative Pressurised water transport and its energy certification. The ENERGOS tool es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.4995/ia.2023.18564
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Alcoy - Escola Politècnica Superior d'Alcoi es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Tecnológico del Agua - Institut Tecnològic de l'Aigua es_ES
dc.description.bibliographicCitation Cabrera, E.; Ortiz, M.; Gómez, E.; Maximino, P.; Del Teso, R.; Marco, C. (2023). El transporte de agua a presión y su certificación energética. La herramienta ENERGOS. Ingeniería del Agua. 27(1):13-28. https://doi.org/10.4995/ia.2023.18564 es_ES
dc.description.accrualMethod OJS es_ES
dc.relation.publisherversion https://doi.org/10.4995/ia.2023.18564 es_ES
dc.description.upvformatpinicio 13 es_ES
dc.description.upvformatpfin 28 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 27 es_ES
dc.description.issue 1 es_ES
dc.identifier.eissn 1886-4996
dc.relation.pasarela OJS\18564 es_ES
dc.description.references ABB (Asea Brown Boveri), 2018. Technical note: IEC 60034-30-1 standard on efficiency classes for low voltage AC motors. ABB Ltd. Switzerland. es_ES
dc.description.references AENOR (Asociación Española de Normalización y Certificación), 2016. Eficiencia mínima requerida de las bombas de agua rotodinámicas. Versión española de la Norma Europea EN 16480:2016. Madrid. es_ES
dc.description.references Arregui, F., Cabrera, E., Pardo, M.A., Martínez, C. 2006. Convenio de colaboración para asesorar técnicamente a la Confederación Hidrográfica del Júcar en la elaboración de directrices relativas a la instalación, utilización y mantenimiento de equipos de medida en captaciones de agua subterránea y su adecuación al uso final. Confederación Hidrográfica del Júcar. Valencia. es_ES
dc.description.references ASCE (American Society of Civil Engineers). 2020. The Economic Benefits of Investing in Water Infrastructure. How a Failure to Act Would Affect the US Economic Recovery. 2020. ASCE. US. es_ES
dc.description.references BOE (Boletín Oficial del Estado). 2001. Real Decreto Legislativo 1/2001, de 20 de julio, por el que se aprueba el texto refundido de la Ley de Aguas. Madrid. es_ES
dc.description.references BOE (Boletín Oficial del Estado). 2016. Real Decreto 56/2016, de 12 de febrero, por el que se transpone la Directiva 2012/27/UE del Parlamento Europeo y del Consejo, de 25 de octubre de 2012, relativa a la eficiencia energética, en lo referente a auditorías energéticas, acreditación de proveedores de servicios y auditores energéticos y promoción de la eficiencia del suministro de energía. Madrid. es_ES
dc.description.references BOE (Boletín Oficial del Estado). 2021a. Ley de Cambio climático. Ley 7/2021, de 20 de mayo, de cambio climático y transición energética. Madrid. es_ES
dc.description.references BOE (Boletín Oficial del Estado), 2021b. Real Decreto 390/2021, de 1 de junio, por el que se aprueba el procedimiento básico para la certificación de la eficiencia energética de los edificios. Madrid. es_ES
dc.description.references Burt, M., Piao, X., Gaudi, F., Busch, B. Taufik, N.F.N. 2008. Electric Motor Efficiency under Variable Frequencies and Loads. Journal of irrigation and drainage engineering, 134(2), 129-136. https://doi.org/10.1061/(ASCE)0733-9437(2008)134:2(129) es_ES
dc.description.references Burton, A., Bent, C., Horne, B., Grossman, C., Wai Cheng, W., Orgill, Y., Philpot, C., Schein, J., Xue, B. 2019. Review of international water efficiency labelling, report prepared by the International Water Association Efficient Urban Water Management Specialist Group. es_ES
dc.description.references Cabrera, E., del Teso, R., Gómez, E., Estruch-Juan, E., Soriano, J., 2019. Quick energy assessment of irrigation water transport systems. Biosystems Engineering, 188, 96-105. https://doi.org/10.1016/j.biosystemseng.2019.10.013 es_ES
dc.description.references Cabrera, E., Gómez, E., Cabrera, E. Jr., Soriano, J., Espert, V. 2015. Energy assessment of pressurized water systems. Journal of Water Resources Planning and Management, 141(8), 04014095. https://doi.org/10.1061/(ASCE)WR.1943-5452.0000494 es_ES
dc.description.references Cabrera, E., del Teso, R., Gómez, E., Cabrera, Jr E., Estruch-Juan, E., 2021. Deterministic Model to Estimate the Energy Requirements of Pressurized Water Transport Systems. Water, 13, 345. https://doi.org/10.3390/w13030345 es_ES
dc.description.references Gómez, E., Cabrera, E., Cabrera, E. Jr., Soriano, J. 2018. Labeling water transport efficiencies. Water. https://doi.org/10.3390/w10070935 es_ES
dc.description.references CE (Comisión Europea). 2022. Comunicación de la Comisión al Parlamento Europeo, al Consejo Europeo, al Consejo, al Comité Económico y Social Europeo y al Comité Europeo de las Regiones del Plan REPowerEU. COM (2022) 230 final. Bruselas. es_ES
dc.description.references Corominas, J. 2010. Agua y energía en el riego, en la época de la sostenibilidad. Ingeniería del Agua. 17(3), 219-233. https://doi.org/10.4995/ia.2010.2977 es_ES
dc.description.references Custodio, E. 2022. Consideraciones sobre el pasado, presente y futuro de las aguas subterráneas en España. Ingeniería del Agua. 26(1), 1-17. https://doi.org/10.4995/ia.2022.16245 es_ES
dc.description.references DOE (Department of Energy). 2012. Energy Efficiency &Renewable Energy. Adjustable Speed Drive Part-Load Efficiency. Washington, DC. USA. es_ES
dc.description.references EC (European Commission). 2012. Commission regulation (EU) No 547/2012 of 25 June 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water pumps. Official Journal of the European Union 26.6.2012. es_ES
dc.description.references EC (European Commission). 2020. In focus: A new generation of EU energy labels. Energy Department of the European Commission. Brussels. es_ES
dc.description.references EC (European Commission), 2021. In focus: A new generation of EU energy labels. https://ec.europa.eu/info/news. Visitado el 27 de septiembre de 2022. es_ES
dc.description.references ECS (Energy Charter Secretariat). 2009. Introducing Energy Efficiency Standards and Labels for Appliances and Equipment. Brussels. es_ES
dc.description.references EEFIG (Energy Efficiency Financial Institutions Group). 2015. Energy Efficiency – the first fuel for the EU Economy. How to drive new finance for energy efficiency investments. Final report covering Buildings, Industry and SMEs. EEFIG. Marseille. February 2015. es_ES
dc.description.references Espinosa-Tasón, J., Berbel, J., Gutiérrez-Martín, C., 2020. Energized water: Evolution of water-energy nexus in the Spanish irrigated agriculture, 1950–2017. Agricultural Water Management, 233, April 2020. https://doi.org/10.1016/j.agwat.2020.106073 es_ES
dc.description.references Grundfos. 2014. High efficiency motor technology that reduces energy waste in pump applications. Grundfos. Dinamarca. es_ES
dc.description.references IDAE (Instituto para la Diversificación y Ahorro de la Energía), 2008. Protocolo de Auditoría Energética en Comunidades de Regantes. IDAE. Madrid. es_ES
dc.description.references IEA (International Energy Agency), 2020. Energy Efficiency Indicators highlights (2020 edition). IEA. Paris. es_ES
dc.description.references IEA (International Energy Agency), 2021. World Energy Outlook. 2021. IEA. Paris. es_ES
dc.description.references IEA (International Energy Agency), 2022. Electricity consumption in the water sector by process, 040, Paris https://www.iea.org/data-and-statistics/charts/electricity-consumption-in-the-water-sector-by-process-2014-2040. Visitada el 26 de septiembre 2022. es_ES
dc.description.references OJEU (Official Journal of the European Union). 2017. Regulation (EU) 2017/1369 of the European Parliament and of the Council of 4 July 2017 setting a framework for energy labelling and repealing Directive 2010/30/EU. Official Journal of the European Union. 28/7/2017. es_ES
dc.description.references OJEU (Official Journal of the European Union). 2019. Supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with regard to energy labelling of refrigerating appliances and repealing Commission Delegated Regulation (EU) No 1060/2010. Official Journal of the European Union.5/12/2019 es_ES
dc.description.references Pérez Urrestarazu, L. and Burt, C., 2012. Characterization of Pumps for Irrigation in Central California: Potential Energy Savings. Journal of irrigation and drainage engineering. ASCE. September 2012, pp 815-822. https://doi.org/10.1061/(ASCE)IR.1943-4774.0000463 es_ES
dc.description.references Serrano, L., Martínez, J.A. 2017. Máquinas eléctricas. Universidad Politécnica de Valencia. es_ES
dc.description.references Tidwell, V.C., Moreland, B. and Zemlick, K., 2014. Geographic Footprint of Electricity Use for Water Services in the Western U.S. Environmental Science &Technology. American Chemical Society. https://doi.org/10.1021/es5016845 es_ES
dc.description.references UE (Unión Europea), 2019. Reglamento (UE) 2019/1781 de la Comisión de 1 de octubre de 2019 por el que se establecen requisitos de diseño ecológico para los motores eléctricos y los variadores de velocidad de conformidad con la Directiva 2009/125/CE del Parlamento Europeo y del Consejo, se modifica el Reglamento (CE) nº 641/2009. Diario Oficial de la Unión Europea de 25 de Octubre de 2019. Bruselas. es_ES
dc.description.references U.S. Department of Energy, 2012. Adjustable Speed Drive Part-Load Efficiency. Washington, DC, https://www1.eere.energy.gov/manufacturing/tech_assistance/pdfs/motor_tip_sheet11.pdf. es_ES
dc.description.references Vasconcelos, J., Cabrera, E., Gómez, E. and Del Teso, R., 2022. Optimal Energy Gradient for Pumping Systems Supplying Variable Flow Demands. Water Resources Planning and Management. https://doi.org/10.1061/(ASCE)WR.1943-5452.0001600 es_ES
dc.description.references Water in the West, 2013. Water and energy nexus: A literature review. Stanford University. CA. USA es_ES