- -

Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Dolmatov, Dmitry O. es_ES
dc.contributor.author Tarrazó-Serrano, Daniel es_ES
dc.contributor.author Filippov, German A. es_ES
dc.contributor.author Minin, Igor V. es_ES
dc.contributor.author Minin, Oleg V. es_ES
dc.contributor.author Sednev, Dmitry A. es_ES
dc.date.accessioned 2023-03-30T18:01:23Z
dc.date.available 2023-03-30T18:01:23Z
dc.date.issued 2019-12 es_ES
dc.identifier.uri http://hdl.handle.net/10251/192663
dc.description.abstract [EN] Currently, phased arrays have found wide application in ultrasonic nondestructive testing. Volumetric results provided by the inspections with linear phased arrays have low lateral resolution in the elevation direction of such probes. This fact complicates the defects characterization task. In this paper, we suggest the application of the Phase-Reversal Fresnel Zone Plate to increase the resolution of volumetric imaging with linear phased arrays. Application of such plates is aimed at ultrasonic focusing in the elevation plane whereas focusing on the active aperture plane is provided by the application of the Sampling Phased Array. Furthermore, the use of the Phase-Reversal Fresnel Zone Plate is advantageous due to the capability of its 3D printing and introduction to the existing automated testing systems avoiding making changes to the current software and hardware. The effectiveness of the plates was verified experimentally on the existing automated testing system. The obtained experimental results demonstrate that the application of the Phase-Reversal Fresnel Zone Plate allowed achieving the results of the higher resolution as well as improving the signal to noise ratio. es_ES
dc.description.sponsorship This work has been supported by the Spanish MINECO (TEC2015-70939-R) and MICINN (RTI2018-100792-B-I00). The research is funded by the Governmental program "Science", research projects No. 11.3683.2017/4.6 and No. 11.6342.2017/8.9. The research is carried out within the framework of Tomsk Polytechnic University Competitiveness Enhancement Program grant, the Project number is VIU-IShNKB-77/2019. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Sensors es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Automated ultrasonic phased array inspections es_ES
dc.subject 3D ultrasonic imaging es_ES
dc.subject Phased array resolution es_ES
dc.subject Phase-Reversal Fresnel Zone Plate es_ES
dc.subject Ultrasound focusing es_ES
dc.subject Sampling Phased Array es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/s19235080 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-100792-B-I00/ES/FOCALIZACION Y CONFORMACION DE HACES DE ULTRASONIDOS MEDIANTE LENTES PLANAS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI//BES-2016-077133//AYUDAS PARA CONTRATOS PREDOCTORALES PARA LA FORMACION DE DOCTORES-TARRAZO SERRANO/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//TEC2015-70939-R/ES/ESTRUCTURAS SUBWAVELENGTH PARA LA FOCALIZACION DE ULTRASONIDOS DE ALTA INTENSIDAD/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Ministry of Science and Higher Education of the Russian Federation//11.3683.2017%2F4.6/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Ministry of Science and Higher Education of the Russian Federation//11.6342.2017%2F8.9/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/TPU//VIU-IShNKB-77%2F2019//Competitiveness Enhancement Program/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural - Escola Tècnica Superior d'Enginyeria Agronòmica i del Medi Natural es_ES
dc.description.bibliographicCitation Dolmatov, DO.; Tarrazó-Serrano, D.; Filippov, GA.; Minin, IV.; Minin, OV.; Sednev, DA. (2019). Application of Phase-Reversal Fresnel Zone Plates for Improving The Elevation Resolution in Ultrasonic Testing with Phased Arrays. Sensors. 19(23):1-13. https://doi.org/10.3390/s19235080 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/s19235080 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 13 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 19 es_ES
dc.description.issue 23 es_ES
dc.identifier.eissn 1424-8220 es_ES
dc.identifier.pmid 31766335 es_ES
dc.identifier.pmcid PMC6928752 es_ES
dc.relation.pasarela S\399807 es_ES
dc.contributor.funder Tomsk Polytechnic University es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.contributor.funder MINISTERIO DE ECONOMIA Y EMPRESA es_ES
dc.contributor.funder Agencia Estatal de Investigación es_ES
dc.contributor.funder Ministry of Science and Higher Education of the Russian Federation es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem