- -

Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Climent Terol, Estela es_ES
dc.contributor.author Biyikal, Mustafa es_ES
dc.contributor.author Gröninger, Delia es_ES
dc.contributor.author Weller, Michael G. es_ES
dc.contributor.author Martínez-Máñez, Ramón es_ES
dc.contributor.author Rurack, Knut es_ES
dc.date.accessioned 2023-05-18T18:00:16Z
dc.date.available 2023-05-18T18:00:16Z
dc.date.issued 2020-12-21 es_ES
dc.identifier.issn 1433-7851 es_ES
dc.identifier.uri http://hdl.handle.net/10251/193467
dc.description This is the peer reviewed version of the following article: Climent, E., Biyikal, M., Gröninger, D., Weller, M. G., Martínez¿Máñez, R., & Rurack, K. (2020). Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles. Angewandte Chemie International Edition, 59(52), 23862-23869, which has been published in final form at https://doi.org/10.1002/anie.202009000. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving." es_ES
dc.description.abstract [EN] Rapid testing methods for the use directly at a point of need are expected to unfold their true potential especially when offering adequate capabilities for the simultaneous measurement of multiple analytes of interest. Considering the unique modularity, high sensitivity, and selectivity of antibody-gated indicator delivery (gAID) systems, a multiplexed assay for three small-molecule explosives (TATP, TNT, PETN) was thus developed, allowing to detect the analytes simultaneously with a single test strip at lower ppb concentrations in the liquid phase in <5 min using a fluorescence reader or a smartphone for readout. While the TNT and PETN systems were newly developed here, all the three systems also tolerated harsher matrices than buffered aqueous model solutions. Besides a single-track strip, the outstanding modularity of the hybrid biosensor materials in combination with strip-patterning technologies allowed us to obtain a multichannel strip in a straightforward manner, offering comparable analytical performance while allowing to be tailored even more to the user's need. es_ES
dc.description.sponsorship Financial support from the Alexander von Humboldt Foundation (fellowship to E.C.), Germany's Federal Ministry for Economic Affairs and Energy (project DEmONS 06/12), the Spanish Government (project RTI2018-100910-B-C41 (MCUI/FEDER, EU)) and the Generalitat Valenciana (project PROMETEO 2018/024) is gratefully acknowledged. We thank S. Selve (Technical University Berlin) for TEM images, A. Zehl (Humboldt University Berlin) for elemental analysis, D. Pfeifer and C. Jager (BAM, Structural Analysis Division) for NMR support, A. Zimathies (BAM, Structural Analysis Division) for N<INF>2</INF> adsorption/desorption measurements, Y. Salinas and L. E. Santos for support on the materials screening, A. Walter, S. Ramin and A. Hesse for obtaining the sera and R. Gotor and J. Bell for their help in the fabrication of the home-made smartphone periphery. Open access funding enabled and organized by Projekt DEAL. es_ES
dc.language Inglés es_ES
dc.publisher John Wiley & Sons es_ES
dc.relation.ispartof Angewandte Chemie International Edition es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Explosives es_ES
dc.subject Hybrid materials es_ES
dc.subject Multiplexing es_ES
dc.subject Signal amplification es_ES
dc.subject Test-strip analysis es_ES
dc.subject.classification QUIMICA INORGANICA es_ES
dc.title Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1002/anie.202009000 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI//RTI2018-100910-B-C41-AR//MATERIALES POROSOS INTELIGENTES MULTIFUNCIONALES Y DSPOSITIVOS ELECTRONICOS PARA LA LIBERACION DE FARMACOS, DETECCION DE DROGAS Y BIOMARCADORES Y COMUNICACION A NANOESCALA/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GENERALITAT VALENCIANA//PROMETEO%2F2018%2F024//SISTEMAS AVANZADOS DE LIBERACION CONTROLADA/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/BMWI//DEmONS 06%2F12/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Climent Terol, E.; Biyikal, M.; Gröninger, D.; Weller, MG.; Martínez-Máñez, R.; Rurack, K. (2020). Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles. Angewandte Chemie International Edition. 59(52):23862-23869. https://doi.org/10.1002/anie.202009000 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1002/anie.202009000 es_ES
dc.description.upvformatpinicio 23862 es_ES
dc.description.upvformatpfin 23869 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 59 es_ES
dc.description.issue 52 es_ES
dc.identifier.pmid 32894638 es_ES
dc.identifier.pmcid PMC7756650 es_ES
dc.relation.pasarela S\429905 es_ES
dc.contributor.funder Projekt DEAL es_ES
dc.contributor.funder GENERALITAT VALENCIANA es_ES
dc.contributor.funder AGENCIA ESTATAL DE INVESTIGACION es_ES
dc.contributor.funder Alexander von Humboldt Foundation es_ES
dc.contributor.funder European Regional Development Fund es_ES
dc.contributor.funder Bundesministerium für Wirtschaft und Energie, Alemania es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem