- -

Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Navarro-Peris, Emilio es_ES
dc.contributor.author Álvarez Piñeiro, L. es_ES
dc.contributor.author Albaladejo, Paloma es_ES
dc.contributor.author Schnabel, Lena es_ES
dc.contributor.author Corberán, José M. es_ES
dc.date.accessioned 2023-09-21T18:06:49Z
dc.date.available 2023-09-21T18:06:49Z
dc.date.issued 2021-11 es_ES
dc.identifier.issn 0140-7007 es_ES
dc.identifier.uri http://hdl.handle.net/10251/196943
dc.description.abstract [EN] The refrigerant distribution in a brazed plate heat exchanger evaporator with distributor has been studied with a thermographic camera working under different conditions of inlet vapor quality, superheat, and water temperature drop. The thermographies have shown a clear uneven thermal distribution except when superheat is null. In most of the cases, they show that a great part of the liquid accumulates at the end channels of the evaporator. The degradation of the evaporator performance is higher when the water temperature drop has a similar or higher value than the superheat. On the other hand, when the superheat is significantly higher than the water temperature drop, the evaporator performance is very similar to situations in which there is an even distribution of the refrigerant. The registered evaporation temperatures are much lower for the case of 13 K of water temperature drop, highlighting the importance of the influence of this parameter on the evaporator performance. This research is described in two parts, Part A (present paper) including the description of the experimental campaign, the obtained experimental results and the results discussion and Part B including an analysis of the degradation of the evaporation temperature due to the refrigerant maldistribution as well as a deeper analysis of the registered temperatures and of the causes for the great degradation observed when the water temperature drop is increased. es_ES
dc.description.sponsorship The authors would like to acknowledge the Spanish `Ministerio de Economia Y Competitividad', through the project "Maximizacion de la Eficiencia Y Minimizacion del Impacto Ambiental de Bombas de Calor Para la Descarbonizacion de la Calefaccion/ACS en los Edificios de Consumo Casi Nulo" with the reference ENE2017-83665C2-1-P for the given support. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof International Journal of Refrigeration es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Brazed plate heat exchanger es_ES
dc.subject Evaporator es_ES
dc.subject Refrigerant maldistribution es_ES
dc.subject Efficiency es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.subject.classification ESTADISTICA E INVESTIGACION OPERATIVA es_ES
dc.title Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.ijrefrig.2021.04.002 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/ENE2017-83665-C2-1-P/ES/MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION%2FACS EN LOS EDIFICIOS DE CONSUMO CASI NULO/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Navarro-Peris, E.; Álvarez Piñeiro, L.; Albaladejo, P.; Schnabel, L.; Corberán, JM. (2021). Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results. International Journal of Refrigeration. 131:119-128. https://doi.org/10.1016/j.ijrefrig.2021.04.002 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.ijrefrig.2021.04.002 es_ES
dc.description.upvformatpinicio 119 es_ES
dc.description.upvformatpfin 128 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 131 es_ES
dc.relation.pasarela S\455706 es_ES
dc.contributor.funder Agencia Estatal de Investigación es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem