Nonlinear Coda Wave Interferometry with Active and Passive Pumps

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Nonlinear Coda Wave Interferometry with Active and Passive Pumps

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Redondo Pastor, Francisco Javier es_ES
dc.contributor.advisor Coutant, Antonin es_ES
dc.contributor.advisor Abraham, Odile es_ES
dc.contributor.author Erdogan ., Nazan es_ES
dc.date.accessioned 2024-01-04T08:44:40Z
dc.date.available 2024-01-04T08:44:40Z
dc.date.created 2023-10-11
dc.date.issued 2024-01-04 es_ES
dc.identifier.uri http://hdl.handle.net/10251/201457
dc.description.abstract [ES] En el ámbito de las estructuras de hormigón, la técnica de interferometría no lineal de onda codificada (NCWI) se perfila como una potente herramienta para la detección de grietas y la evaluación estructural. A diferencia de los métodos convencionales, la NCWI emplea ruido ambiental para el bombeo pasivo, con el objetivo de sustituir las fuentes de bombeo activas y racionalizar los montajes experimentales. Este estudio pretende explorar la viabilidad del ruido ambiental como fuente de bombeo pasivo para NCWI, aprovechando su sensibilidad a los cambios heterogéneos del medio para mejorar la monitorización del estado del hormigón y la evaluación de infraestructuras. Mediante un meticuloso análisis de los datos, se desvelan los intrincados comportamientos provocados por factores como las fluctuaciones de temperatura, los niveles de bombeo y el ruido del tráfico. Las representaciones visuales ofrecen información sobre la variación de la velocidad, el coeficiente de descorrelación y otras dinámicas, proporcionando información valiosa para la detección de grietas y la evaluación del estado estructural. El estudio disecciona además los datos para descubrir patrones matizados dentro de las mediciones NCWI, distinguiendo comportamientos entre zonas agrietadas y no agrietadas. En particular, surgen correlaciones entre los picos de ruido del tráfico y las variaciones de los parámetros clave, lo que justifica investigaciones rigurosas sobre posibles influencias artificiales. Esta investigación subraya el potencial de la interferometría no lineal de ondas de codo, especialmente en el contexto del bombeo pasivo a través del ruido ambiente, como una vía prometedora para la detección precisa de grietas y la comprensión exhaustiva de las estructuras de hormigón. Este enfoque allana el camino para los avances en los ensayos no destructivos y la supervisión del estado de las infraestructuras. es_ES
dc.description.abstract [EN] In the domain of concrete structures, the Nonlinear Coda Wave Interferometry (NCWI) technique emerges as a potent tool for crack detection and structural assessment. Departing from conventional methods, NCWI employs ambient noise for passive pumping, aiming to replace active pump sources and streamline experimental setups. This study aims to explore the feasibility of ambient noise as a passive pump source for NCWI, leveraging its sensitivity to heterogeneous medium changes to enhance concrete health monitoring and infrastructure assessment. Through meticulous data analysis, intricate behaviors driven by factors like temperature fluctuations, pump levels, and traffic noise are unveiled. Visual representations offer insights into velocity variation, decorrelation coefficient, and other dynamics, providing valuable information for crack detection and structural health evaluation. The study further dissects data to uncover nuanced patterns within NCWI measurements, distinguishing behaviors between crack and uncracked zones. Notably, correlations emerge between traffic noise peaks and variations in key parameters, warranting rigorous investigations into potential artificial influences. This research underscores the potential of Nonlinear Coda Wave Interferometry, particularly in the context of passive pumping through ambient noise, as a promising avenue for precise crack detection and comprehensive understanding of concrete structures. This approach paves the way for advancements in nondestructive testing and infrastructure health monitoring. es_ES
dc.format.extent 41 es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Coda waves es_ES
dc.subject Coda Wave Interferometry es_ES
dc.subject Interferometría es_ES
dc.subject Ondas Coda es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.other Máster Universitario Erasmus Mundus en Ondas, Acústica, Vibraciones, Ingeniería y Sonido / Erasmus Mundus Master in Waves, Acoustics, Vibrations, Engineering and Sound (WAVES)-Màster Universitari Erasmus Mundus en Ondas, Acústica, Vibracions, Enginyeria i So / Erasmus Mundus Master in Waves, Acoustics, Vibrations, Engineering and Sound (WAVES) es_ES
dc.title Nonlinear Coda Wave Interferometry with Active and Passive Pumps es_ES
dc.title.alternative Interferometría no lineal de ondas Coda con bombas activas y pasivas es_ES
dc.title.alternative InterferometrIa no lineal d'ones Coda amb bombes actives i passives es_ES
dc.type Tesis de máster es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia es_ES
dc.description.bibliographicCitation Erdogan ., N. (2023). Nonlinear Coda Wave Interferometry with Active and Passive Pumps. Universitat Politècnica de València. http://hdl.handle.net/10251/201457 es_ES
dc.description.accrualMethod TFGM es_ES
dc.relation.pasarela TFGM\159989 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem