Influence of Different European Code Provisions for Capacity Design on the Seismic Performance of Reinforced Concrete Frames

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Influence of Different European Code Provisions for Capacity Design on the Seismic Performance of Reinforced Concrete Frames

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Gómez-Martínez, Fernando es_ES
dc.contributor.author Perez-Garcia, Agustin es_ES
dc.date.accessioned 2024-04-24T18:06:09Z
dc.date.available 2024-04-24T18:06:09Z
dc.date.issued 2023-08 es_ES
dc.identifier.issn 2075-5309 es_ES
dc.identifier.uri http://hdl.handle.net/10251/203720
dc.description.abstract [EN] Performance-based seismic codes ensure proper inelastic behaviour of reinforced concrete frames through capacity design, among others. This strategy relies not only on avoiding brittle failures and providing ductility to plastic hinges but also in their distribution within the frame aimed at a greater number of storeys involved in the eventual collapse mechanism. Although codes are generally in agreement to some basic principles in order to ensure capacity design, they show some discrepancies regarding the specific strategies. In this paper, capacity design provisions proposed by some European current codes-Eurocode 8, Italian NTC, and Spanish NCSE-02-are compared, and their effectiveness is discussed. The alternative formulation proposed by Italian code for "strong column-weak beam" turns out to be not suitable under specific circumstances, such as with large gravity loads or significant cantilever deformation in lower storeys. Regarding the value of axial load in columns to be considered for the calculation of shear and moment capacities, provisions in the three codes could eventually cause unconservative design for perimeter columns. The Spanish whole set of provisions is proved to not be effective due to their different fundamentals-they are based on overstrength instead of capacity. For all the three cases, some alternative procedures are suggested in this work. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Buildings es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Capacity design es_ES
dc.subject Strong column weak beam es_ES
dc.subject Seismic performance es_ES
dc.subject Plastic hinges es_ES
dc.subject Eurocode 8 es_ES
dc.subject NTC es_ES
dc.subject NCSE-02 es_ES
dc.subject.classification MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS es_ES
dc.title Influence of Different European Code Provisions for Capacity Design on the Seismic Performance of Reinforced Concrete Frames es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/buildings13082051 es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Arquitectura - Escola Tècnica Superior d'Arquitectura es_ES
dc.description.bibliographicCitation Gómez-Martínez, F.; Perez-Garcia, A. (2023). Influence of Different European Code Provisions for Capacity Design on the Seismic Performance of Reinforced Concrete Frames. Buildings. 13(8). https://doi.org/10.3390/buildings13082051 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/buildings13082051 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 13 es_ES
dc.description.issue 8 es_ES
dc.relation.pasarela S\513885 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem