- -

Single instrument for hemostatic control in laparoscopic partial nephrectomy in a porcine model without renal vascular clamping

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Single instrument for hemostatic control in laparoscopic partial nephrectomy in a porcine model without renal vascular clamping

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Subira Rios, Jorge es_ES
dc.contributor.author Sanchez Zalabardo, Jose M. es_ES
dc.contributor.author Burdio, Fernando es_ES
dc.contributor.author Berjano, Enrique es_ES
dc.contributor.author Moros, Manuel es_ES
dc.contributor.author Gonzalez, Ana es_ES
dc.contributor.author Navarro, Ana es_ES
dc.contributor.author Gueemes, Antonio es_ES
dc.date.accessioned 2013-04-30T12:38:25Z
dc.date.available 2013-04-30T12:38:25Z
dc.date.issued 2011
dc.identifier.issn 0892-7790
dc.identifier.uri http://hdl.handle.net/10251/28352
dc.description This is a copy of an article published in the Journal of Endourology ©2011 copyright Mary Ann Liebert, Inc.; Journal of Endourology is available online at: http://www.liebertpub.com/end es_ES
dc.description.abstract [EN] Materials and Methods: We performed a comparative experimental study between a new radiofrequency (RF)-assisted device consisting of a handheld instrument that simultaneously conducts coagulation and cutting tasks without hilar clamping vs a standard technique with hilar clamping. A porcine model was used (10 animals per group) with survival of 17 days. Results: The estimated blood loss with the new device was significantly lower than with the standard technique (15.5 +/- 23.7 vs 79.4 +/- 76.3 mL). Although transection time was longer with the new device (10.7 +/- 13.7 vs 2.1 +/- 1.2 min), the total operative time was significantly shorter (35.3 +/- 13.7 vs 60.2 +/- 10.5 min). Evidence of localized urinary extravasation (urinoma) was identical in both groups (five cases). The group subjected to the new device, however, showed a significantly higher number of cases of leakage after conducting the methylene-blue test: eight (80%) cases vs only one (11%) with the standard technique. Necrosis depth was significantly greater with the new device (6.6 +/- 0.9 vs <1 mm). Conclusions: The experimental results suggest that the proposed RF-assisted device provides adequate hemostatic control during transection of the renal parenchyma without additional instruments or surgical maneuvers and could therefore be a valuable adjunct for LPN without vascular clamping. The device was unsuccessful in effectively sealing the collecting system. es_ES
dc.description.sponsorship This work received financial support from the Spanish "Plan Nacional de I + D + I del Ministerio de Ciencia e Innovacion," Grant No. TEC2008-01369/TEC. The translation of this paper was funded by the Universidad Politecnica de Valencia, Valencia, Spain. en_EN
dc.language Inglés es_ES
dc.publisher Mary Ann Liebert es_ES
dc.relation.ispartof Journal of Endourology and Part B, Videourology es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Radiofrequency-assisted device es_ES
dc.subject Bloodless rapid transection es_ES
dc.subject Liver resection es_ES
dc.subject Pig-liver es_ES
dc.subject High-density es_ES
dc.subject In-vivo es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Single instrument for hemostatic control in laparoscopic partial nephrectomy in a porcine model without renal vascular clamping es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1089/end.2010.0557
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//TEC2008-01369/ES/MODELOS COMPUTACIONALES E INVESTIGACION EXPERIMENTAL EN EL ESTUDIO DE TECNICAS QUIRURGICAS DE CALENTAMIENTO DE TEJIDOS BIOLOGICOS MEDIANTE CORRIENTES DE RADIOFRECUENCIA./ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.description.bibliographicCitation Subira Rios, J.; Sanchez Zalabardo, JM.; Burdio, F.; Berjano, E.; Moros, M.; Gonzalez, A.; Navarro, A.... (2011). Single instrument for hemostatic control in laparoscopic partial nephrectomy in a porcine model without renal vascular clamping. Journal of Endourology and Part B, Videourology. 25(6):1005-1011. https://doi.org/10.1089/end.2010.0557 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1089/end.2010.0557 es_ES
dc.description.upvformatpinicio 1005 es_ES
dc.description.upvformatpfin 1011 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 25 es_ES
dc.description.issue 6 es_ES
dc.relation.senia 214128
dc.contributor.funder Ministerio de Ciencia e Innovación es_ES
dc.contributor.funder Universitat Politècnica de València es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem