dc.description.abstract | El principal objetivo de este trabajo de fin de máster es caracterizar y acondicionar una cámara reverberante a escala, de manera que sea un recinto en el que ensayar con fiabilidad, a medias y altas frecuencias, el coeficiente de absorción de materiales y pantallas acústicas. La cámara reverberante es uno de los laboratorios acústicos más utilizados para determinar el coeficiente de absorción de materiales o la potencia acústica radiada por diferentes emisores. Contamos con una serie de normas que definen las condiciones tanto del recinto de ensayo, como de los materiales o dispositivos expuestos a estudio. En el cálculo del coeficiente de absorción acústica, las superficies de los materiales a ensayar deben estar comprendidas entre 10 y 12 m2 (UNE-EN ISO 354:2004). Sin embargo, a nivel de investigación de nuevos materiales acústicos, en la mayoría de los casos sólo se dispone de pequeñas probetas que no llegan a las dimensiones requeridas. Por ello se ha diseñado y construido un recinto de ensayo de menores dimensiones que la cámara reverberante de la EPSG, concretamente a escala 1:6, para poder trabajar con muestras de reducido tamaño. Debido a sus características físicas, como la longitud de las aristas o el volumen del recinto, entre otras, los resultados del coeficiente de absorción obtenido para diferentes materiales distan significativamente de los obtenidos en la cámara reverberante de la escuela. Es por ello que creemos necesaria una caracterización de la cámara y una mejora en las condiciones de ensayo para alcanzar resultados más fidedignos. | es_ES |
dc.description.abstract | The main objective of this work is to describe and condition a scale reverberation chamber, so that is a room in which to test reliability, mid and high frequencies, the absorption coefficient of acoustic materials and screens. The reverberation chamber is one of the most used acoustic laboratories to determine the absorption coefficient of materials or sound power radiated by different sources. We have a set of rules that define the conditions both in the test chamber, as the materials or devices subject to study. In the calculation of the acoustic absorption coefficient of the surfaces of the materials to be tested should be between 10 and 12 m2 (UNE-EN ISO 354:2004). However, at the level of acoustic materials research, in most cases only small samples are available that do not reach the required dimensions. Therefore it has been designed and built a test chamber, smaller than the EPSG reverberation chamber, specifically 1:6 scale, to work with small sample size. Because of their physical characteristics, such as edge length or volume of the enclosure, among others, the results of the absorption coefficient obtained for different materials significantly far from those obtained in the reverberation room of the school. That is why we need a characterization of the camera and improved the test conditions to reach more reliable results | es_ES |
dc.format.extent | 43 | es_ES |
dc.language | Español | es_ES |
dc.publisher | Universitat Politècnica de València | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Cámara reverberante | es_ES |
dc.subject | Coeficiente de absorción | es_ES |
dc.subject | Pantalla acústica | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.subject.other | Máster Universitario en Ingeniería Acústica-Màster Universitari en Enginyeria Acústica | es_ES |
dc.title | Adecuación y validación de una cámara reverberante a escala para ensayos de pantallas acústicas | es_ES |
dc.type | Tesis de máster | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Investigación para la Gestión Integral de Zonas Costeras - Institut d'Investigació per a la Gestió Integral de Zones Costaneres | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Politécnica Superior de Alcoy - Escola Politècnica Superior d'Alcoi | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Escuela Politécnica Superior de Gandia - Escola Politècnica Superior de Gandia | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica - Centre de Tecnologies Físiques: Acústica, Materials i Astrofísica | es_ES |
dc.description.bibliographicCitation | Teira Arnoso, A. (2013). Adecuación y validación de una cámara reverberante a escala para ensayos de pantallas acústicas. Universitat Politècnica de València. http://hdl.handle.net/10251/29015 | es_ES |
dc.description.accrualMethod | Archivo delegado | es_ES |