- -

Energy efficient supermarket refrigeration with ejectors

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Energy efficient supermarket refrigeration with ejectors

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.advisor Eikevik, Trygve M. es_ES
dc.contributor.author Calvo Hoyas, Raúl es_ES
dc.date.accessioned 2016-06-13T12:05:45Z
dc.date.available 2016-06-13T12:05:45Z
dc.date.created 2016-06
dc.date.issued 2016-06-13
dc.identifier.uri http://hdl.handle.net/10251/65755
dc.description.abstract Consulta en la Biblioteca ETSI Industriales (Riunet) es_ES
dc.description.abstract [EN] Nowadays, the use of R744 or carbon dioxide has been increased as a working fluid in many refrigerant systems. Nevertheless, one disadvantage for use this refrigerant is the thermodynamic losses produced in the refrigerant system when the fluid is throttled. These losses are increased if the refrigerant system is working in transcritical operation conditions. But, there is an option and it consists of using an ejector instead of the conventional expansion valve in order to reduce the energy losses and to increase the energy efficiency of the R744 refrigerant system. Thus, the R744 ejector refrigeration system is converted into a real possibility comparing to the conventional refrigeration system and it provides a significant reduction of the environmental contamination. This work has been performed with the purpose to increase the knowledge about how the ejector refrigeration system works at different operation conditions by means of an experimental analysis. Also, the test facility used in this experimental analysis is a two phase ejector refrigeration system with R744 as a working fluid. The experimental results obtained show that the ejector works more efficiently using a pressure lift between 4 and 9 bar and with a entrainment ratio from 0.10 to 0.48, approximately. Furthermore, the ejector efficiency achieves the higher values working with the pressure ratio between 1.1 to 1.35, and the highest efficiency is found at the pressure ratio of 1.275, approximately. Besides, it is demonstrated that working at high inlet temperatures the ejector efficiency is better than working at low temperatures. This is due to the fact that more energy is saved by the ejector working at high temperatures because the expansion work is bigger than using the ejector at low temperatures. Therefore, it is shown that the ejector performs more efficiently in warm climates than running the ejector in cold climates. es_ES
dc.language Inglés es_ES
dc.publisher Universitat Politècnica de València es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Consulta en la Biblioteca ETSI Industriales es_ES
dc.subject Energy efficient es_ES
dc.subject Refrigeration es_ES
dc.subject.classification TECNOLOGIA DEL MEDIO AMBIENTE es_ES
dc.subject.other Ingeniero Industrial-Enginyer Industrial es_ES
dc.title Energy efficient supermarket refrigeration with ejectors es_ES
dc.type Proyecto/Trabajo fin de carrera/grado es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Calvo Hoyas, R. (2016). Energy efficient supermarket refrigeration with ejectors. http://hdl.handle.net/10251/65755. es_ES
dc.description.accrualMethod Archivo delegado es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem