Testing for individual approval of a vault roof with in-plane loades glass panes

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Testing for individual approval of a vault roof with in-plane loades glass panes

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author WELLER, Bernhard
dc.contributor.author REICH, Stefan
dc.contributor.author EBERT, Jan
dc.contributor.author KRAMPE, Philipp
dc.contributor.editor Domingo Cabo, Alberto es_ES
dc.contributor.editor Lázaro Fernández, Carlos Manuel es_ES
dc.date.accessioned 2009-12-18T10:51:15Z
dc.date.available 2009-12-18T10:51:15Z
dc.date.issued 2009-12-18T10:51:15Z
dc.identifier.isbn 978-84-8363-461-5
dc.identifier.uri http://hdl.handle.net/10251/6704
dc.description p. 2990-3001 en_EN
dc.description.abstract At the IASS conferences in 2007 [1] and 2008 the concept and testing results of a sustainable and transparent roof construction were presented. These transparent space grid structures base on a double layer grid in which all bars in the upper layer, the compression layer, are replaced by glass panes. The glazing is part of the primary load bearing system and transfers significant in-plane forces. In 2007 the first realisation project using this new concept was launched and will be finished this year. With a dimension of 13.5 m x 21 m and an arch rise of 3.50 m it covers the courtyard of one of the Berlin palaces. The design process was attended with extensive testing to obtain an individual approval. This contribution describes the testing at single panes and the full-scale arch of 13.5 m span necessary for the individual approval of the building authorities. Plastics for the in-plane load application into the glass edge and their creeping behaviour were investigated in first tests. The stability behaviour against glass pane buckling was tested at relevant load combinations and the post breakage robustness and the walk-on ability of the overhead glazing ensured by suitable test. Load bearing tests with a total load of 13 tons were conducted at one 13.5 m arch and finished the test series. The successfully finished testing is the basis for the individual approval and the realisation of the roof construction within the next month. en_EN
dc.language Inglés en_EN
dc.publisher Editorial Universitat Politècnica de València es_ES
dc.relation.ispartof Symposium of the International Association for Shell and Spatial Structures (50th. 2009. Valencia). Evolution and Trends in Design, Analysis and Construction of Shell and Spatial Structures : Proceedings en_EN
dc.rights Reserva de todos los derechos en_EN
dc.subject Glass en_EN
dc.subject Individual approval en_EN
dc.subject Space structure en_EN
dc.subject Roof en_EN
dc.subject Testing en_EN
dc.subject Mock-up en_EN
dc.title Testing for individual approval of a vault roof with in-plane loades glass panes en_EN
dc.type Comunicación en congreso en_EN
dc.rights.accessRights Abierto es_ES
dc.description.bibliographicCitation Weller, B.; Reich, S.; Ebert, J.; Krampe, P. (2009). Testing for individual approval of a vault roof with in-plane loades glass panes. Editorial Universitat Politècnica de València. http://hdl.handle.net/10251/6704 es_ES
dc.relation.conferencename Symposium of the International Association for Shell and Spatial Structures es_ES
dc.relation.conferencedate 2009 es_ES
dc.relation.conferenceplace Valencia es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem