- -

Massive Immuno Multiresidue Screening of Water Pollutants

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Massive Immuno Multiresidue Screening of Water Pollutants

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Dobosz, Paulina Dorota es_ES
dc.contributor.author Morais, Sergi es_ES
dc.contributor.author Bonet, Emilio es_ES
dc.contributor.author Puchades, Rosa es_ES
dc.contributor.author Maquieira Catala, Ángel es_ES
dc.date.accessioned 2016-07-07T07:19:48Z
dc.date.issued 2015-10-06
dc.identifier.issn 0003-2700
dc.identifier.uri http://hdl.handle.net/10251/67275
dc.description.abstract [EN] An immuno multiresidue screening assay in microarray format for the determination of complex chemical mixtures at the microgram per liter level, using antibody-functionalized gold nanoparticles, is presented. The analytical method relies on the use of a cocktail of nanogold-labeled specific antibodies, acting as recognition and detection species. The concept of multireside screening is proved by developing a multiplex assay on a compact disk support for the determination of 2-(2,4,5- trichlorophenoxy)propionic acid, 3-phenoxybenozic acid, 4-nitrophenol, alachlor, atrazine, azoxystrobin, chlorpyrifos, diazinon, diuron, endosulfan, fenthion, forchlorfenuron, imidacloprid, malathion, pentachlorophenol, pyraclostrobin, sulfasalazine, and triclosan, achieving detection limits of 0.07, 0.24, 10.9, 0.21, 0.14, 0.11, 0.11, 102, 0.36, 1.8, 1.7, 0.06, 0.08, 5.8, 1.0, 0.39, 0.003, and 12 ug/L, respectively. Due to the selectivity of the antibody-functionalized nanoparticles, the developed screening methodology allows the simultaneous determination of mixtures of water pollutants in a 10-plex configuration. The analytical performances were compared with those of reference chromatographic methods by the analysis of spiked water samples, the sensitivity and recovery results being in good agreement. The presented screening approach directly quantifies the concentration of complex chemical mixtures without sample treatment or preconcentration steps in a total time of 35 min. es_ES
dc.description.sponsorship This work was supported by the Spanish Ministry of Economy and Competitiveness (Project CTQ2013-45875-R) and by the Generalitat Valenciana (Grants PROMETEO II 2014/040 and ACOMP 2012/158). P.D. acknowledges a fellowship (Grant Grisolia 2011/010) funded by the Generalitat Valenciana for her Ph.D. studies. Dr. A. Montoya, Dr. A. Abad-Fuentes, Dr. Shirley Gee, and Prof. Bruce D. Hammock kindly provided some of the coating conjugates and antibodies used in this work. en_EN
dc.language Inglés es_ES
dc.publisher American Chemical Society es_ES
dc.relation.ispartof Analytical Chemistry es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject LINKED-IMMUNOSORBENT-ASSAY es_ES
dc.subject MONOCLONAL-ANTIBODIES es_ES
dc.subject DISK es_ES
dc.subject TECHNOLOGY es_ES
dc.subject EXTRACTION es_ES
dc.subject PESTICIDE es_ES
dc.subject RESIDUES es_ES
dc.subject SAMPLES es_ES
dc.subject ELISA es_ES
dc.subject.classification QUIMICA ANALITICA es_ES
dc.title Massive Immuno Multiresidue Screening of Water Pollutants es_ES
dc.type Artículo es_ES
dc.embargo.lift 10000-01-01
dc.embargo.terms forever es_ES
dc.identifier.doi 10.1021/acs.analchem.5b02354
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//CTQ2013-45875-R/ES/BIOSENSADO EN SOPORTES INTERACTIVOS CON PROPIEDADES INTERFEROMETRICAS PARA APLICACIONES CLINICAS. DEMOSTRACION EN FARMACOGENETICA Y ALERGIAS MEDICAMENTOSAS/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2014%2F040/ES/Estudio de estrategias fisico-químicas para el desarrollo de biosensores interferométricos en soportes interactivos de aplicación en clínica/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACOMP%2F2012%2F158/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//GRISOLIA%2F2011%2F010/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Química - Departament de Química es_ES
dc.description.bibliographicCitation Dobosz, PD.; Morais, S.; Bonet, E.; Puchades, R.; Maquieira Catala, Á. (2015). Massive Immuno Multiresidue Screening of Water Pollutants. Analytical Chemistry. 87(19):9817-9824. https://doi.org/10.1021/acs.analchem.5b02354 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://dx.doi.org/10.1021/acs.analchem.5b02354 es_ES
dc.description.upvformatpinicio 9817 es_ES
dc.description.upvformatpfin 9824 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 87 es_ES
dc.description.issue 19 es_ES
dc.relation.senia 297336 es_ES
dc.identifier.eissn 1520-6882
dc.contributor.funder Ministerio de Economía y Competitividad
dc.contributor.funder Generalitat Valenciana


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem