Application of ground-penetrating radar technique to evaluate the waterfront location in hardened concrete

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Application of ground-penetrating radar technique to evaluate the waterfront location in hardened concrete

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Rodríguez Abad, Isabel es_ES
dc.contributor.author Klysz, Gilles es_ES
dc.contributor.author Martínez Sala, Rosa María es_ES
dc.contributor.author Balayssac, Jean Paul es_ES
dc.contributor.author Mené Aparicio, Jesús es_ES
dc.date.accessioned 2017-04-04T12:09:19Z
dc.date.available 2017-04-04T12:09:19Z
dc.date.issued 2016-12-15
dc.identifier.issn 2193-0856
dc.identifier.uri http://hdl.handle.net/10251/79443
dc.description.abstract The long-term performance of concrete structures is directly tied to two factors: concrete durability and strength. When assessing the durability of concrete structures, the study of the water penetration is paramount, because almost all reactions like corrosion, alkali-silica, sulfate, etc., which produce their deterioration, require the presence of water. Ground-penetrating radar (GPR) has shown to be very sensitive to water variations. On this basis, the objective of this experimental study is, firstly, to analyze the correlation between the water penetration depth in concrete samples and the GPR wave parameters. To do this, the samples were immersed into water for different time intervals and the wave parameters were obtained from signals registered when the antenna was placed on the immersed surface of the samples. Secondly, a procedure has been developed to be able to determine, from those signals, the reliability in the detection and location of waterfront depths. The results have revealed that GPR may have an enormous potential in this field, because excellent agreements were found between the correlated variables. In addition, when comparing the water-front depths calculated from GPR measurements and those visually registered after breaking the samples, we observed that they totally agreed when the waterfront was more than 4 cm depth. es_ES
dc.description.sponsorship The authors are grateful to COST - European Cooperation in Science and Technology (www.cost.eu) for funding the Action TU1208 "Civil engineering applications of Ground Penetrating Radar" (www.GPRadar.eu). The authors also thank the Laboratorio de Materiales de Construcion of the Escuela Tecnica Superior de Ingenieria de la Edificacion de la Universitat Politecnica de Valencia technical team for the valuable collaboration. en_EN
dc.language Inglés es_ES
dc.publisher European Geosciences Union (EGU) es_ES
dc.relation.ispartof Geoscientific Instrumentation, Methods and Data Systems es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject DIELECTRIC-PROPERTIES es_ES
dc.subject GPR es_ES
dc.subject MOISTURE es_ES
dc.subject.classification MECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURAS es_ES
dc.title Application of ground-penetrating radar technique to evaluate the waterfront location in hardened concrete es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.5194/gi-5-567-2016
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials es_ES
dc.description.bibliographicCitation Rodríguez Abad, I.; Klysz, G.; Martínez Sala, RM.; Balayssac, JP.; Mené Aparicio, J. (2016). Application of ground-penetrating radar technique to evaluate the waterfront location in hardened concrete. Geoscientific Instrumentation, Methods and Data Systems. 5(2):567-574. doi:10.5194/gi-5-567-2016 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.5194/gi-5-567-2016 es_ES
dc.description.upvformatpinicio 567 es_ES
dc.description.upvformatpfin 574 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 5 es_ES
dc.description.issue 2 es_ES
dc.relation.senia 325246 es_ES
dc.identifier.eissn 2193-0864
dc.contributor.funder European Cooperation in Science and Technology
dc.description.references Klysz, G. and Balayssac, J. P.: Determination of volumetric water content of concrete using ground-penetrating radar, Cement Concrete Res., 37, 164–117, https://doi.org/10.1016/j.cemconres.2007.04.010, 2007. es_ES
dc.description.references Klysz, G., Balayssac, J. P., and Ferrières, X.: Evaluation of dielectric properties of concrete by a numerical FDTD model of a GPR coupled antenna-Parametric study, NDT&E Int., 41, 621–631, https://doi.org/10.1016/j.ndteint.2008.03.011, 2008. es_ES
dc.description.references Lai, W. L., Kou, S. C., Tsang, W. F., and Poon, C. S.: Characterization of concrete properties from dielectric properties using ground penetrating radar, Cement Concrete Res., 39, 687–695, https://doi.org/10.1016/j.cemconres.2009.05.004, 2009. es_ES
dc.description.references Laurens, S., Balayssac, J. P., Rhazi, J., Klysz, G., and Arliguie, G.: Non-destructive evaluation of concrete moisture by GPR: experimental study and direct modelling, Mater. Struct., 38, 827–832, 2005. es_ES
dc.description.references Martínez-Sala, R., Rodríguez-Abad, I., and Del Val, I.: Effect of penetration of water under pressure in hardened concrete on GPR signals, Proceedings of the International Workshop on Advanced Ground Penetrating Radar (IWAGPR 2013), Nantes, France, 237–242, 2013. es_ES
dc.description.references Martínez-Sala, R., Rodríguez-Abad, I., Mené-Aparicio, J., and Fernández Castilla, A.: Study of the waterfront advance in hardened concrete by means of energy level increment analysis, Proceedings of the 8th International Workshop on Advanced Ground Penetrating Radar (IWAGPR), Firenze, Italy, https://doi.org/10.1109/IWAGPR.2015.7292695, 2015. es_ES
dc.description.references Otieno, M. B., Alexander, M. G., and Beushausen, H. D.: Corrosion in cracked and uncracked concrete – influence of crack width, concrete quality and crack reopening, Mag. Concrete Res., 62, 393–404, 2010. es_ES
dc.description.references Pérez Gracia, V.: Radar del subsuelo. Evaluación en arqueología y patrimonio histórico-artístico, PhD doctoral thesis, Universitat Politècnica de Catalunya, Spain, 2001. es_ES
dc.description.references Rodríguez-Abad, I., Martínez-Sala, R., Mené, J., and Klysz, G.: Water penetrability in hardened concrete by GPR, Proceedings of the 15th International Conference on Ground Penetrating Radar, Brussels, Belgium, 862–867, 2014. es_ES
dc.description.references Rodríguez-Abad, I., Klysz, G., Martínez-Sala, R., Blayssac, J. P., and Mené, J.: Waterfront depth analysis in hardened concrete by means of the nondestructive ground penetrating radar, IEEE J. Sel. Top. Appl., 9, 91–97, 2016a. es_ES
dc.description.references Rodríguez-Abad, I., Klysz, G., Balayssac, J. P., and Pajewski, L.: Assessment of waterfront location in hardened concrete by GPR within COST Action TU1208, European Geosciences Union (EGU) General Assembly 2016, Vienna, Austria, EGU2016-18427, 2016b. es_ES
dc.description.references Sbartaï, Z. M., Laurens, S., Balayssac, J. P., Ballivy, G., and Arliguie, G.: Effect of concrete moisture on radar signal amplitude, ACI Mater. J., 103, 419–426, 2006. es_ES
dc.description.references Senin, S. F. and Hamis, R.: Ground penetrating radar wave attenuation models for estimation of moisture and chloride content in concrete slab, Constr. Build. Mater., 106, 659–669, https://doi.org/10.1016/j.conbuildmat.2015.12.156, 2015. es_ES
dc.description.references Soutsos, M. N., Bungey, J. H., Miljard, S. G., Shaw, M. R., and Patterson, A.: Dielectric properties of concrete and their influence on radar testing, NDT&E Int., 34, 419–425, 2001. es_ES
dc.description.references Tosti, F. and Slob, E.: Determination, by Using GPR, of the Volumetric Water Content in Structures, Substructures, Foundations and Soil, Civil Engineering Applications of Ground Penetrating Radar, 1, Benedetto, A., Pajewski, L., Springer International Publishing, Switzerland, 163–194, https://doi.org/10.1007/978-3-319-04813-0, 2015. es_ES
dc.description.references UNE-EN 12390-2:2009/1M:2015, Testing hardened concrete. Part 2: Making and curing specimens for strength test, AEN/CTN83-Hormigón, AENOR, 2015. es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem