- -

Quantitative determination of spring water quality parameters via electronic tongue

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Quantitative determination of spring water quality parameters via electronic tongue

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Carbó-Mestre, Noèlia es_ES
dc.contributor.author López-Carrero, Javier es_ES
dc.contributor.author Garcia-Castillo, F. Javier es_ES
dc.contributor.author Tormos, Isabel es_ES
dc.contributor.author Olivas, Estela es_ES
dc.contributor.author Folch, Elisa es_ES
dc.contributor.author Alcañiz Fillol, Miguel es_ES
dc.contributor.author Soto Camino, Juan es_ES
dc.contributor.author Martínez-Máñez, Ramón es_ES
dc.contributor.author Martínez-Bisbal, M.Carmen es_ES
dc.date.accessioned 2018-03-05T05:20:41Z
dc.date.available 2018-03-05T05:20:41Z
dc.date.issued 2018 es_ES
dc.identifier.uri http://hdl.handle.net/10251/98791
dc.description.abstract [EN] The use of a voltammetric electronic tongue for the quantitative analysis of quality parameters in spring water is proposed here. The electronic voltammetric tongue consisted of a set of four noble electrodes (iridium, rhodium, platinum, and gold) housed inside a stainless steel cylinder. These noble metals have a high durability and are not demanding for maintenance, features required for the development of future automated equipment. A pulse voltammetry study was conducted in 83 spring water samples to determine concentrations of nitrate (range: 6.9-115 mg/L), sulfate (32-472 mg/L), fluoride (0.08-0.26 mg/L), chloride (17-190 mg/L), and sodium (11-94 mg/L) as well as pH (7.3-7.8). These parameters were also determined by routine analytical methods in spring water samples. A partial least squares (PLS) analysis was run to obtain a model to predict these parameter. Orthogonal signal correction (OSC) was applied in the preprocessing step. Calibration (67%) and validation (33%) sets were selected randomly. The electronic tongue showed good predictive power to determine the concentrations of nitrate, sulfate, chloride, and sodium as well as pH and displayed a lower R-2 and slope in the validation set for fluoride. Nitrate and fluoride concentrations were estimated with errors lower than 15%, whereas chloride, sulfate, and sodium concentrations as well as pH were estimated with errors below 10%. es_ES
dc.description.sponsorship The authors gratefully acknowledge the Ministerio de Economia y Competitividad and FEDER, providing funds amounting to (sic)664.525,75 for the project "Desarrollo de sistemas basados en lenguas electronicas para el control y monitorizacion del ciclo integral del agua" INNPACTO. IPT-2012-0069-310000. Moreover, the authors gratefully acknowledge the Ministerio de Economia y Competitividad and FEDER (projects MAT2015-64139-C4-1-R (MINECO/FEDER), MAT2015-64139-C4-3-R (MINECO/FEDER)), the Generalitat Valenciana (project PROMETEOII/2014/047), and CIBER-BBN (NANOPROBE project) for their financial support. en_EN
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Sensors es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Spring water es_ES
dc.subject Electronic voltammetric tongue es_ES
dc.subject Water quality control es_ES
dc.subject Partial least squares es_ES
dc.subject.classification QUIMICA INORGANICA es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Quantitative determination of spring water quality parameters via electronic tongue es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/s18010040 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//MAT2015-64139-C4-3-R/ES/DESARROLLO DE EQUIPOS Y DISPOSITIVOS ELECTRONICOS COMO SISTEMA DE DETECCION Y ACTUACION BASADOS EN NUEVAS TECNOLOGIAS ELECTRONICAS. APLICACION AL AREA BIOMEDICA./ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//MAT2015-64139-C4-1-R/ES/NANOMATERIALES INTELIGENTES, SONDAS Y DISPOSITIVOS PARA EL DESARROLLO INTEGRADO DE NUEVAS HERRAMIENTAS APLICADAS AL CAMPO BIOMEDICO/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//IPT-2012-0069-310000/ES/Desarrollo de sistemas basados en lenguas electrónicas para el control y monitorización del ciclo integral del agua. e-TONGUE4WAT/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2014%2F047/ES/Nuevas aproximaciones para el diseño de materiales de liberación controlada y la detección de compuestos peligrosos/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Química - Departament de Química es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic es_ES
dc.description.bibliographicCitation Carbó-Mestre, N.; López-Carrero, J.; Garcia-Castillo, FJ.; Tormos, I.; Olivas, E.; Folch, E.; Alcañiz Fillol, M.... (2018). Quantitative determination of spring water quality parameters via electronic tongue. Sensors. 18(1):1-12. https://doi.org/10.3390/s18010040 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/s18010040 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 12 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 18 es_ES
dc.description.issue 1 es_ES
dc.identifier.eissn 1424-8220 es_ES
dc.identifier.pmid 29295592 en_EN
dc.identifier.pmcid PMC5795646 en_EN
dc.relation.pasarela S\350205 es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Economía, Industria y Competitividad es_ES
dc.description.references Winquist, F., Olsson, J., & Eriksson, M. (2011). Multicomponent analysis of drinking water by a voltammetric electronic tongue. Analytica Chimica Acta, 683(2), 192-197. doi:10.1016/j.aca.2010.10.027 es_ES
dc.description.references Storey, M. V., van der Gaag, B., & Burns, B. P. (2011). Advances in on-line drinking water quality monitoring and early warning systems. Water Research, 45(2), 741-747. doi:10.1016/j.watres.2010.08.049 es_ES
dc.description.references Winquist, F. (2008). Voltammetric electronic tongues – basic principles and applications. Microchimica Acta, 163(1-2), 3-10. doi:10.1007/s00604-007-0929-2 es_ES
dc.description.references Garçon, L.-A., Genua, M., Hou, Y., Buhot, A., Calemczuk, R., Livache, T., … Hou, Y. (2017). A Versatile Electronic Tongue Based on Surface Plasmon Resonance Imaging and Cross-Reactive Sensor Arrays—A Mini-Review. Sensors, 17(5), 1046. doi:10.3390/s17051046 es_ES
dc.description.references Hou, Y., Genua, M., Tada Batista, D., Calemczuk, R., Buhot, A., Fornarelli, P., … Livache, T. (2012). Continuous Evolution Profiles for Electronic-Tongue-Based Analysis. Angewandte Chemie International Edition, 51(41), 10394-10398. doi:10.1002/anie.201205346 es_ES
dc.description.references Holmin, S., Spångeus, P., Krantz-Rülcker, C., & Winquist, F. (2001). Compression of electronic tongue data based on voltammetry — a comparative study. Sensors and Actuators B: Chemical, 76(1-3), 455-464. doi:10.1016/s0925-4005(01)00585-8 es_ES
dc.description.references Campos, I., Alcañiz, M., Aguado, D., Barat, R., Ferrer, J., Gil, L., … Vivancos, J.-L. (2012). A voltammetric electronic tongue as tool for water quality monitoring in wastewater treatment plants. Water Research, 46(8), 2605-2614. doi:10.1016/j.watres.2012.02.029 es_ES
dc.description.references Martı́nez-Máñez, R., Soto, J., Garcia-Breijo, E., Gil, L., Ibáñez, J., & Llobet, E. (2005). An «electronic tongue» design for the qualitative analysis of natural waters. Sensors and Actuators B: Chemical, 104(2), 302-307. doi:10.1016/j.snb.2004.05.022 es_ES
dc.description.references Garcia-Breijo, E., Atkinson, J., Gil-Sanchez, L., Masot, R., Ibañez, J., Garrigues, J., … Olguin, C. (2011). A comparison study of pattern recognition algorithms implemented on a microcontroller for use in an electronic tongue for monitoring drinking waters. Sensors and Actuators A: Physical, 172(2), 570-582. doi:10.1016/j.sna.2011.09.039 es_ES
dc.description.references Moreno, L., Merlos, A., Abramova, N., Jiménez, C., & Bratov, A. (2006). Multi-sensor array used as an «electronic tongue» for mineral water analysis. Sensors and Actuators B: Chemical, 116(1-2), 130-134. doi:10.1016/j.snb.2005.12.063 es_ES
dc.description.references Sipos, L., Kovács, Z., Sági-Kiss, V., Csiki, T., Kókai, Z., Fekete, A., & Héberger, K. (2012). Discrimination of mineral waters by electronic tongue, sensory evaluation and chemical analysis. Food Chemistry, 135(4), 2947-2953. doi:10.1016/j.foodchem.2012.06.021 es_ES
dc.description.references Braga, G. S., Paterno, L. G., & Fonseca, F. J. (2012). Performance of an electronic tongue during monitoring 2-methylisoborneol and geosmin in water samples. Sensors and Actuators B: Chemical, 171-172, 181-189. doi:10.1016/j.snb.2012.02.092 es_ES
dc.description.references Escobar, J. D., Alcaniz, M., Masot, R., Fuentes, A., Bataller, R., Soto, J., & Barat, J. M. (2013). Quantification of organic acids using voltammetric tongues. Food Chemistry, 138(2-3), 814-820. doi:10.1016/j.foodchem.2012.11.078 es_ES
dc.description.references Martínez-Bisbal, M. C., Loeff, E., Olivas, E., Carbó, N., García-Castillo, F. J., López-Carrero, J., … Soto, J. (2017). A Voltammetric Electronic Tongue for the Quantitative Analysis of Quality Parameters in Wastewater. Electroanalysis, 29(4), 1147-1153. doi:10.1002/elan.201600717 es_ES
dc.description.references Bonastre, A., Ors, R., Capella, J. V., Fabra, M. J., & Peris, M. (2005). In-line chemical analysis of wastewater: present and future trends. TrAC Trends in Analytical Chemistry, 24(2), 128-137. doi:10.1016/j.trac.2004.09.008 es_ES
dc.description.references Ivarsson, P., Johansson, M., Höjer, N.-E., Krantz-Rülcker, C., Winquist, F., & Lundström, I. (2005). Supervision of rinses in a washing machine by a voltammetric electronic tongue. Sensors and Actuators B: Chemical, 108(1-2), 851-857. doi:10.1016/j.snb.2004.12.088 es_ES
dc.description.references Garcia-Breijo, E., Peris, R. M., Pinatti, C. O., Fillol, M. A., Civera, J. I., & Prats, R. B. (2013). Low-Cost Electronic Tongue System and Its Application to Explosive Detection. IEEE Transactions on Instrumentation and Measurement, 62(2), 424-431. doi:10.1109/tim.2012.2215156 es_ES
dc.description.references Winquist, F., Wide, P., & Lundström, I. (1997). An electronic tongue based on voltammetry. Analytica Chimica Acta, 357(1-2), 21-31. doi:10.1016/s0003-2670(97)00498-4 es_ES
dc.description.references Campos, I., Sangrador, A., Bataller, R., Aguado, D., Barat, R., Soto, J., & Martínez-Máñez, R. (2014). Ammonium and Phosphate Quantification in Wastewater by Using a Voltammetric Electronic Tongue. Electroanalysis, 26(3), 588-595. doi:10.1002/elan.201300538 es_ES
dc.description.references Geladi, P., & Kowalski, B. R. (1986). Partial least-squares regression: a tutorial. Analytica Chimica Acta, 185, 1-17. doi:10.1016/0003-2670(86)80028-9 es_ES
dc.description.references Wold, S., Antti, H., Lindgren, F., & Öhman, J. (1998). Orthogonal signal correction of near-infrared spectra. Chemometrics and Intelligent Laboratory Systems, 44(1-2), 175-185. doi:10.1016/s0169-7439(98)00109-9 es_ES
dc.description.references Sjöblom, J., Svensson, O., Josefson, M., Kullberg, H., & Wold, S. (1998). An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra. Chemometrics and Intelligent Laboratory Systems, 44(1-2), 229-244. doi:10.1016/s0169-7439(98)00112-9 es_ES
dc.description.references Rouhollahi, A., Rajabzadeh, R., & Ghasemi, J. (2006). Simultaneous determination of dopamine and ascorbic acid by linear sweep voltammetry along with chemometrics using a glassy carbon electrode. Microchimica Acta, 157(3-4), 139-147. doi:10.1007/s00604-006-0668-9 es_ES
dc.description.references Riahi, S., Ganjali, M., Moghaddam, A., Pourbasheer, E., & Norouzi, P. (2009). Development of a New Combined Chemometrics Method, Applied in the Simultaneous Voltammetric Determination of Cinnamic Acid and 3, 4-Dihydroxy Benzoic Acid. Current Analytical Chemistry, 5(1), 42-47. doi:10.2174/157341109787047925 es_ES
dc.description.references Palacios-Santander, J. M., Cubillana-Aguilera, L. M., Cocchi, M., Ulrici, A., Naranjo-Rodríguez, I., Seeber, R., & Hidalgo-Hidalgo de Cisneros, J. L. (2008). Multicomponent analysis in the wavelet domain of highly overlapped electrochemical signals: Resolution of quaternary mixtures of chlorophenols using a peg-modified Sonogel–Carbon electrode. Chemometrics and Intelligent Laboratory Systems, 91(2), 110-120. doi:10.1016/j.chemolab.2007.10.004 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem