Enhancing timing performance of heterostructures with double-sided readout

dc.contributor.authorPagano, Fiammettaes_ES
dc.contributor.authorKratochwil, Nicolauses_ES
dc.contributor.authorLowis, Carstenes_ES
dc.contributor.authorChoong, Woon-Senges_ES
dc.contributor.authorPaganoni, Marcoes_ES
dc.contributor.authorPizzichemi, Marcoes_ES
dc.contributor.authorCates, Joshua W.es_ES
dc.contributor.authorAuffray, Etiennettees_ES
dc.contributor.funderNational Institutes of Health, EEUUes_ES
dc.contributor.funderBundesministerium für Bildung und Forschung, Alemaniaes_ES
dc.date.accessioned2024-10-21T18:03:05Z
dc.date.available2024-10-21T18:03:05Z
dc.date.issued2024-10-21es_ES
dc.description.abstract[EN] Objective. Heterostructured scintillators offer a promising solution to balance the sensitivity and timing in TOF-PET detectors. These scintillators utilize alternating layers of materials with complementary properties to optimize performance. However, the layering compromises time resolution due to light transport issues. This study explores double-sided readout-enabling improved light collection and Depth-of-Interaction (DOI) information retrieval-to mitigate this effect and enhance the timing capabilities of heterostructures. Approach. The time resolution and DOI performances of 3 x 3 x 20 mm3 BGO&EJ232 heterostructures were assessed in a single and double-sided readout (SSR and DSR, respectively) configuration using high-frequency electronics. Main results. Selective analysis of photopeak events yielded a DOI resolution of 6.4 +/- 0.04 mm. Notably, the Coincidence Time Resolution (CTR) improved from 262 +/- 8 ps (SSR) to 174 +/- 6 ps (DSR) when measured in coincidence with a fast reference detector. Additionally, symmetrical configuration of two identical heterostructures in coincidence was tested, yielding in DSR a CTR of 254 +/- 8 ps for all photopeak events and 107 +/- 5 ps for the fastest events. Significance. By using high-frequency double-sided readout, we could measure DOI resolution and improve the time resolution of heterostructures of up to 40%. The DOI information resulted intrinsically captured in the average between the timestamps of the two SiPMs, without requiring any further correction.en_EN
dc.description.accrualMethodSes_ES
dc.description.bibliographicCitationPagano, F.; Kratochwil, N.; Lowis, C.; Choong, W.; Paganoni, M.; Pizzichemi, M.; Cates, JW.... (2024). Enhancing timing performance of heterostructures with double-sided readout. Physics in Medicine and Biology. 69(20). https://doi.org/10.1088/1361-6560/ad7fc8es_ES
dc.description.issue20es_ES
dc.description.sponsorshipThis work was carried out in the frame of the Crystal Clear Collaboration. It received support from the CERN Budget for Knowledge Transfer to Medical Applications and from the Wolfgang Gentner Programme of the German Federal Ministry of Education and Research (Grant No. 13E18CHA). Some material was based upon work supported by the National Institutes of Health under research Grant R01EB028286. The authors would like to thank Isabel Frank for her help in the preparation of the mechanics for the experimental setup.es_ES
dc.description.volume69es_ES
dc.identifier.doi10.1088/1361-6560/ad7fc8es_ES
dc.identifier.issn0031-9155es_ES
dc.identifier.pmid39321964es_ES
dc.identifier.urihttps://riunet.upv.es/handle/10251/210641
dc.languageIngléses_ES
dc.publisherIOP Publishinges_ES
dc.relation.ispartofPhysics in Medicine and Biologyes_ES
dc.relation.pasarelaS\529031es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/BMBF//13E18CHA/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/NIH//R01EB028286/es_ES
dc.relation.publisherversionhttps://doi.org/10.1088/1361-6560/ad7fc8es_ES
dc.rightsReconocimiento (by)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectTime-of-flight PETes_ES
dc.subjectCoincidence time resolutiones_ES
dc.subjectHeterostructured scintillatorses_ES
dc.subjectDepth of interactiones_ES
dc.subjectHigh-frequencyes_ES
dc.subjectDouble-sided readoutes_ES
dc.titleEnhancing timing performance of heterostructures with double-sided readoutes_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuidaf42f99e-06d0-416a-a7e7-f8166fe0101des_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
PaganoKratochwilLowis - Enhancing timing performance of heterostructures with double-sided readout.pdf
Tamaño:
1.58 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial