Evaluación de humedales artificiales de flujo libre superficial con macrófitas acuáticas flotantes

dc.contributor.authorSoler, C.es_ES
dc.contributor.authorCrespi, R.es_ES
dc.contributor.authorSoler, E.es_ES
dc.contributor.authorPugliese, M.es_ES
dc.contributor.funderUniversidad Nacional de Río Cuarto
dc.date.accessioned2018-05-03T07:03:11Z
dc.date.available2018-05-03T07:03:11Z
dc.date.issued2018-04-27
dc.date.updated2018-05-03T06:41:24Z
dc.description.abstract[EN] The aim of this study was to evaluate the behavior of constructed wetlands with aquatic macrophytes in decreasing the concentration of pollutants from urban effluents. A pilot-scale system with two coverages of floating plants and two hydraulic residence times, working with continuous flow laminar was built. The lower concentration of chemical oxygen demand and biological oxygen demand, were obtained with the lower coverage and higher hydraulic residence times. With little influence of the variables on the concentration of total nitrogen and total suspended solids, being the significant response for total phosphorus with the lowest plant coverage. There was a highly significant removal of total coliforms, regardless of coverage and in favor of higher hydraulic residence times. The use of free water surface wetlands is auspicious for sanitary control, showing low incidence on total nitrogen and total phosphorus.en_EN
dc.description.abstract[ES] El objetivo del presente trabajo fue evaluar el comportamiento de humedales artificiales con macrófitas acuáticas, en la concentración de contaminantes de efluentes urbanos. Se construyó un sistema a escala piloto, con dos coberturas de plantas flotantes y dos tiempos de residencia hidráulico, trabajando con flujo laminar continuo. La menor concentración de la demanda química de oxígeno y la demanda biológica de oxígeno, se obtuvieron con la menor cobertura y el mayor tiempo de residencia hidráulico; registrándose poca influencia de las variables en la concentración de nitrógeno total y sólidos suspendidos totales, siendo la respuesta significativa para fósforo total con la menor cobertura de plantas. Hubo una remoción altamente significativa de coliformes totales, independientemente de la cobertura y a favor del mayor tiempo de residencia hidráulico. El uso de humedales de flujo libre superficial es auspicioso para el control sanitario, demostrando baja incidencia sobre nitrógeno total y fósforo total.es_ES
dc.description.accrualMethodSWORDes_ES
dc.description.bibliographicCitationSoler, C.; Crespi, R.; Soler, E.; Pugliese, M. (2018). Evaluación de humedales artificiales de flujo libre superficial con macrófitas acuáticas flotantes. Ingeniería del Agua. 22(2):69-78. https://doi.org/10.4995/ia.2018.8596es_ES
dc.description.issue2
dc.description.referencesAPHA-AWWA-WPCF. 1998. Métodos normalizados para el análisis de aguas potables y aguas residuales. España: Ed. Díaz de Santos.es_ES
dc.description.referencesBillore, S.K., Singh, N. Sharma, J.K. 2001. ROOTZONE: Una ecotecnología de humedales prometedora y favorable al entorno para el tratamiento de vertidos municipales. Revista Internacional de Agua y Riego, 21(1), 26-31. ISSN 0334-5807.es_ES
dc.description.referencesÇakir, R., Gidirislioglu, A., Çebi, U. 2015. A study on the effects of different hydraulic loading rates (HLR) on pollutant removal efficiency of subsurface horizontal-flow constructed wetlands used for treatment of domestic wastewaters. Journal of Environmental Management, 164, 121-128. https://doi.org/10.1016/j.jenvman.2015.08.037es_ES
dc.description.referencesChen, Y., Wen, Y., Zhou, Q., Huang, J., Vymazal, J., Kuschk, P. 2016. Sulfate removal and sulfur transformation in constructed wetlands: The roles of filling material and plant biomass. Water Research, 102, 572-581. https://doi.org/10.1016/j.watres.2016.07.001es_ES
dc.description.referencesCrespi, R., Plevich, O., Thuar, A., Grosso, L., Rodríguez, C., Ramos, D., Barotto, O., Sartori, M., Covinich, M., Boehler, J. 2007. Manejo de aguas residuales urbanas. En XXI Congreso Nacional del Agua 2007. Tucumán, 15 al 19 de Mayo de 2007. Argentina.es_ES
dc.description.referencesDelgadillo, O., Camacho, A., Pérez, L., Andrade, M. 2010. Depuración de aguas residuales por medio de humedales artificiales. 105 pág. Cochabamba. Bolivia: Ed. Nelson Antequera Durán.es_ES
dc.description.referencesDi Luca, G., Maine, M., Mufarrege , M., Hadad, H., Sánchez, G., Bonetto C. 2011. Metal retention and distribution in the sediment of a constructed wetland for industrial wastewater treatment. Ecological Engineering, 37(9), 1267-1275. https://doi.org/10.1016/j.ecoleng.2011.03.003es_ES
dc.description.referencesEl-Sheikh, M., Saleh, H., El-Quosy, D., Mahmoud, A. 2010. Improving water quality in polluated drains with free water surface constructed wetlands. Ecological Engineering, 36(10), 1478-1484. https://doi.org/10.1016/j.ecoleng.2010.06.030es_ES
dc.description.referencesElZein, Z., Abdou, A., Abd ElGawad, I. 2016. Constructed Wetlands as a Sustainable Wastewater Treatment Method in Communities. Procedia Environmental Sciences, 34, 605-617. https://doi.org/10.1016/j.proenv.2016.04.053es_ES
dc.description.referencesEPA- Environmental Protection Agency. 1993. Constructed Wetlands for Wastewater Treatment and Wildlife Habitat. EPA 832-R-93-005. 19 pág. United States.es_ES
dc.description.referencesEPA- Environmental Protection Agency. 2000. Humedales de Flujo libre superficial. Folleto Informativo de Aguas residuales. EPA 832-F-00-024. 10 pág. United States.es_ES
dc.description.referencesFernández González, J., Beascoechea, E., Muñoz, M., De la Mora, J. 2005. Manual de Fitodepuración. Filtros de macrófitas en flotación. 146 pág. Madrid: Ed. Universidad Politécnica de Madrid.es_ES
dc.description.referencesFernández J., 2012. Fitodepuración por humedales artificiales. 30 pág. Foro de debate sobre la depuración de agua en Aragón. Universidad Politécnica de Madrid.es_ES
dc.description.referencesGandy, C., Davis, J., Orme, P., Potter, H., Jarvis, A. 2016. Metal removal mechanisms in a short hydraulic residence time subsurface flow compost wetland for mine drainage treatment. Ecological Engineering, 97, 179-185. https://doi.org/10.1016/j.ecoleng.2016.09.011es_ES
dc.description.referencesHuang, J., Reneau, R., Hagedorn, C. 2000. Nitrogen removal in constructed wetlands employed to treat domestic wastewater. Water Research, 34(9), 2582-2588. https://doi.org/10.1016/S0043-1354(00)00018-Xes_ES
dc.description.referencesKotti, I., Gikas, G., Tsihrintzis, V. 2010. Effect of operational and design parameters on removal efficiency of pilot-scale FWS constructed wetlands and comparison with HSF systems. Ecological Engineering, 36(7), 862-875. https://doi.org/10.1016/j.ecoleng.2010.03.002es_ES
dc.description.referencesPavlineri, N., Skoulikidis, N., Tsihrintzis, V. 2017. Constructed Floating Wetlands: A review of research, design, operation and management aspects, and data meta-analysis. Review. Chemical Engineering Journal, 308, 1120-1132. https://doi.org/10.1016/j.cej.2016.09.140es_ES
dc.description.referencesPeña Varón, M.,Van Ginneken, M., Madera, P. 2003. Humedales de Flujo Subsuperficial: Una alternativa natural para el tratamiento de aguas residuales domésticas en zonas tropicales. Ingeniería y Competitividad, 5(1), 27-35. https://doi.org/10.25100/iyc.v5i1.2302es_ES
dc.description.referencesPérez, C. 2001. Técnicas estadísticas con SPSS. Madrid. España: Pearson Educación S.A.es_ES
dc.description.referencesRodríguez-González, M., Molina-Burgos, J., Jácome-Burgos, A., Suárez-López, J. 2013. Humedal de flujo vertical para tratamiento terciario del efluente físico-químico de una estación depuradora de aguas residuales domésticas. Ingeniería, Investigación y Tecnología, 14(2), 223-235. https://doi.org/10.1016/S1405-7743(13)72238-8es_ES
dc.description.referencesSirianuntapiboon, S., Kongchum, M., Jitmaikasem, W. 2006. Effects of hydraulic retention time and media of constructed wetland for treatment of domestic wastewater. African Journal of Agricultural Research, 1(2), 027-037.es_ES
dc.description.referencesScholz, M. 2016. Constructed Wetlands.Chapter 20.Pages 137-155. In: Wetlands for Water Pollution Control (Second Edition). Salford, UK: The University of Salford. https://doi.org/10.1016/B978-0-444-63607-2.00020-4es_ES
dc.description.referencesSiracusa, G., La Rosa, A. 2006. Design of a constructed wetland for wastewater treatment in a Sicilian town and environmental evaluation using the emergy analysis. Ecological modelling, 197(3-4), 490-497. https://doi.org/10.1016/j.ecolmodel.2006.03.019es_ES
dc.description.referencesSoler, E. 2009. Ideas para investigar. Rosario. Argentina: Ed. Homo Sapiens.es_ES
dc.description.referencesUpadhyay, A., Bankoti, N., Rai, U. 2016. Studies on sustainability of simulated constructed wetland system for treatment of urban waste: Design and operation. Journal of Environmental Management, 169, 285-292. https://doi.org/10.1016/j.jenvman.2016.01.004es_ES
dc.description.referencesWu S., Carvalho P. , Müller J., Manoj V., Dong R. 2016. Sanitation in constructed wetlands: A review on the removal of human pathogens and fecal indicators. Science of the Total Environment, 541, 8-22. https://doi.org/10.1016/j.scitotenv.2015.09.047es_ES
dc.description.referencesZachritz II, W., Hanson, A., Sauceda, J., Fitzsimmons, K. 2008. Evaluation of submerged surface flow (SSF) constructed wetlands for recirculating tilapia production systems. Aquacultural Engineering, 39, 16-23. https://doi.org/10.1016/j.aquaeng.2008.05.001es_ES
dc.description.sponsorshipEste proyecto se realizó en el marco del Programa de Investigación “Evaluación de Tecnologías para el Tratamiento y Reutilización de Efluentes Urbanos”. Programa 2012-2014, subsidiado por la SECyT (Secretaria de Ciencia y Técnica de la Nación). Particularmente este trabajo en la línea de investigación con humedales, se realizó con aportes privados del tesista de posgrado.es_ES
dc.description.upvformatpfin78es_ES
dc.description.upvformatpinicio69es_ES
dc.description.volume22
dc.identifier.doi10.4995/ia.2018.8596
dc.identifier.eissn1886-4996
dc.identifier.issn1134-2196
dc.identifier.urihttps://riunet.upv.es/handle/10251/101244
dc.languageEspañoles_ES
dc.publisherUniversitat Politècnica de València
dc.relation.ispartofIngeniería del Agua
dc.relation.publisherversionhttps://doi.org/10.4995/ia.2018.8596es_ES
dc.relation.references10.1016/j.jenvman.2015.08.037es_ES
dc.relation.references10.1016/j.watres.2016.07.001es_ES
dc.relation.references10.1016/j.ecoleng.2011.03.003es_ES
dc.relation.references10.1016/j.ecoleng.2010.06.030es_ES
dc.relation.references10.1016/j.proenv.2016.04.053es_ES
dc.relation.references10.1016/j.ecoleng.2016.09.011es_ES
dc.relation.references10.1016/S0043-1354(00)00018-Xes_ES
dc.relation.references10.1016/j.ecoleng.2010.03.002es_ES
dc.relation.references10.1016/j.cej.2016.09.140es_ES
dc.relation.references10.25100/iyc.v5i1.2302es_ES
dc.relation.references10.1016/S1405-7743(13)72238-8es_ES
dc.relation.references10.1016/B978-0-444-63607-2.00020-4es_ES
dc.relation.references10.1016/j.ecolmodel.2006.03.019es_ES
dc.relation.references10.1016/j.jenvman.2016.01.004es_ES
dc.relation.references10.1016/j.scitotenv.2015.09.047es_ES
dc.relation.references10.1016/j.aquaeng.2008.05.001es_ES
dc.rightsReconocimiento - No comercial - Sin obra derivada (by-nc-nd)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectAguas residuales urbanases_ES
dc.subjectTratamientoes_ES
dc.subjectHumedales artificialeses_ES
dc.subjectPlantas flotanteses_ES
dc.subjectPlanta pilotoes_ES
dc.subjectUrban wastewateres_ES
dc.subjectTreatmentes_ES
dc.subjectConstructed wetlandses_ES
dc.subjectFloating plantses_ES
dc.subjectPilot plantes_ES
dc.titleEvaluación de humedales artificiales de flujo libre superficial con macrófitas acuáticas flotanteses_ES
dc.title.alternativePerformance of free water surface flow constructed wetland with floating aquatic macrophyteses_ES
dc.typeArtículoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuidca28ed85-0d4d-418a-868a-4c827db2ce15es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
8596-36920-1-PB.pdf
Tamaño:
1.02 MB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
359 B
Formato:
Item-specific license agreed upon to submission
Descripción: