Analytical behaviour of concrete-encased CFST box stub columns under axial compression

dc.contributor.authorChen, Jin-Yanges_ES
dc.contributor.authorHan, Lin-Haies_ES
dc.contributor.authorWang, Fa-Chenges_ES
dc.contributor.authorMu, Ting-Mines_ES
dc.date.accessioned2018-10-02T06:13:30Z
dc.date.available2018-10-02T06:13:30Z
dc.date.issued2018-06-05
dc.description.abstract[EN] Concrete-encased CFST (concrete-filled steel tube) members have been widely used in high-rise buildings and bridge structures. In this paper, the axial performance of a typical concrete-encased CFST box member with inner CFST and outer reinforced concrete (RC) is investigated. A finite element analysis (FEA) model is established to analyze the compressive behavior of the composite member. The material nonlinearity and the interaction between concrete and steel tube are considered. A good agreement is achieved between the measured and predicted results in terms of the failure mode and the load-deformation relation. The verified FEA model is then used to conduct the full range analysis on the load versus deformation relations. The loading distributions of different components inclouding concrete, steel tube and longitudinal bar during four stages are discussed. Typical failure modes, internal force distribution, stress development and the contact stress between concrete and steel tube are also presented. The parametric study on the compressive behavior is conducted to investigate the effects of various parameters, e.g. the strength of concrete and steel, longitudinal bar ratio and stirrup space on the sectional capacity and the ductility of the concrete-encased CSFT box member.en_EN
dc.description.accrualMethodOCSes_ES
dc.description.bibliographicCitationChen, J.; Han, L.; Wang, F.; Mu, T. (2018). Analytical behaviour of concrete-encased CFST box stub columns under axial compression. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 401-408. https://doi.org/10.4995/ASCCS2018.2018.6966es_ES
dc.description.upvformatpfin408es_ES
dc.description.upvformatpinicio401es_ES
dc.format.extent8es_ES
dc.identifier.doi10.4995/ASCCS2018.2018.6966
dc.identifier.isbn9788490486016
dc.identifier.urihttps://riunet.upv.es/handle/10251/108883
dc.languageIngléses_ES
dc.publisherEditorial Universitat Politècnica de Valènciaes_ES
dc.relation.conferencedateJunio 27-29,2018es_ES
dc.relation.conferencename12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018es_ES
dc.relation.conferenceplaceValencia, Spaines_ES
dc.relation.ispartofProceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018es_ES
dc.relation.pasarelaOCS\6966es_ES
dc.relation.publisherversionhttp://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/6966es_ES
dc.rightsReconocimiento - No comercial - Sin obra derivada (by-nc-nd)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectConcrete-filled steel tube (CFST)es_ES
dc.subjectConcrete-encasedes_ES
dc.subjectBox memberes_ES
dc.subjectCompresive behaviores_ES
dc.subjectFull-range analysises_ES
dc.titleAnalytical behaviour of concrete-encased CFST box stub columns under axial compressiones_ES
dc.typeCapítulo de libroes_ES
dc.typeComunicación en congresoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuiddbe81585-e417-4ce7-803c-3f4a9fd3c138es_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
6966-22585-1-PB.pdf
Tamaño:
1.28 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial