dc.description.abstract[EN] High strength concrete encased columns are being developed for erecting high-rise buildings as their higher load bearing capacity and smaller cross section size than normal concrete encased column. At ambient temperature, high strength concrete is always mixed with steel fibers to improve its ductility to match the material properties of high strength steel while constructing concrete encased columns. However, for high strength concrete at elevated temperature, spalling usually can be observed due to different thermal properties of various materials mixed such as siliceous aggregate, cement, silica fume, grit and moisture. Most of previous studies present that pore vapor compression induces high strength concrete spalling and propylene fiber can prevent it from spalling. The aim of the present experimental study is to discover the minimum propylene fiber ratio to prevent spalling of 115~120MPa concrete with aggregate and steel fiber. The experimental study carried out on 17 specimens with different water-binder ratio, steel fiber ratio and monofilament propylene fiber ratio exposed to ISO834 fire. The test results that 0.15% by volume of propylene fibers can prevent 115/120MPa high strength concrete with aggregate from spalling. It is worth noting that propylene fiber mixture ratio of 0.15% is lower than that of EN 1992-1-2 proposed up to 0.22%. Lower propylene fiber mixture ratio has been soak to improve the workability of 115~120MPa high strength concrete with steel fibers.en_EN
dc.description.accrualMethodOCSes_ES
dc.description.bibliographicCitationDu, Y.; Zhu, Y.; Liew, R. (2018). Experimental study on spalling risk of concrete with 115~120MPa subject to ISO834 Fire. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 857-861. https://doi.org/10.4995/ASCCS2018.2018.7024es_ES
dc.description.sponsorshipThe authors gratefully acknowledge the financial support of the International Structural Fire Research Laboratory (ISFRL) in Nanjing Tech University, China.es_ES
dc.description.upvformatpfin861es_ES
dc.description.upvformatpinicio857es_ES
dc.format.extent5es_ES
dc.identifier.doi10.4995/ASCCS2018.2018.7024
dc.identifier.isbn9788490486016
dc.identifier.urihttps://riunet.upv.es/handle/10251/108222
dc.languageIngléses_ES
dc.publisherEditorial Universitat Politècnica de Valènciaes_ES
dc.relation.conferencedateJunio 27-29,2018es_ES
dc.relation.conferencename12th international conference on ‘Advances in Steel-Concrete Composite Structures’ - ASCCS 2018es_ES
dc.relation.conferenceplaceValencia, Spaines_ES
dc.relation.ispartofProceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018es_ES
dc.relation.pasarelaOCS\7024es_ES
dc.relation.publisherversionhttp://ocs.editorial.upv.es/index.php/ASCCS/ASCCS2018/paper/view/7024es_ES
dc.rightsReconocimiento - No comercial - Sin obra derivada (by-nc-nd)es_ES
dc.rights.accessRightsAbiertoes_ES
dc.subjectISO 834 firees_ES
dc.subjectHigh strength concretees_ES
dc.subjectPropylene fiberes_ES
dc.subjectSpallinges_ES
dc.subjectSteel fiberes_ES
dc.titleExperimental study on spalling risk of concrete with 115~120MPa subject to ISO834 Firees_ES
dc.typeCapítulo de libroes_ES
dc.typeComunicación en congresoes_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dspace.entity.typePublication
upv.uuidfed75bdd-d25f-46cd-9c98-68a9ae68203fes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
7024-22681-1-PB.pdf
Tamaño:
1.41 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión editorial