Mostrar el registro sencillo del ítem
dc.contributor.author | Campos Sánchez, Inmaculada![]() |
es_ES |
dc.contributor.author | Gil Sánchez, Luís![]() |
es_ES |
dc.contributor.author | Martínez-Máñez, Ramón![]() |
es_ES |
dc.contributor.author | Soto Camino, Juan![]() |
es_ES |
dc.contributor.author | Vivancos, José-Luis![]() |
es_ES |
dc.date.accessioned | 2018-04-14T04:14:06Z | |
dc.date.available | 2018-04-14T04:14:06Z | |
dc.date.issued | 2009 | es_ES |
dc.identifier.issn | 1876-6196 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/100407 | |
dc.description.abstract | [EN] An electronic tongue (ET) based on pulse voltammetry containing a set of eight metallic electrodes (Au, Pt, Ir, Rh, Cu, Co, Ni and Ag) encapsulated on a stainless steel cylinder has been used to discriminate and predict levels of nerve agent mimics in aqueous environments. Analysis including principal component analysis (PCA) and partial least square techniques (PLS) have been applied for data management and prediction models. A good discrimination from other organophosphorous derivatives was found for the nerve agent simulants diethyl-chlorophosphate (DCP) and diethyl-cyanophosphate (DCNP). | es_ES |
dc.description.sponsorship | We thank the Ministerio de Ciencia y Tecnologia (project CTQ2006-15456-C04-01), and Universidad Politecnica de Valencia (project PAID-06-07-3243) for support. I.C. thanks the Universidad Politecnica de Valencia for a Doctoral Fellowship. | |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Procedia Chemistry | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Electronic tongue | es_ES |
dc.subject | Voltammetry | es_ES |
dc.subject | Nerve agent mimics | es_ES |
dc.subject.classification | PROYECTOS DE INGENIERIA | es_ES |
dc.subject.classification | QUIMICA INORGANICA | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | Use of a voltammetric electronic tongue for predicting levels of nerve agent mimics | es_ES |
dc.type | Artículo | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.identifier.doi | 10.1016/j.proche.2009.07.081 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//PAID-06-07-3243/ES/PAID-06-07-3243/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MEC//CTQ2006-15456-C04-01/ES/DESARROLLO DE NUEVOS PROTOCOLOS DE RECONOCIMIENTO CROMO-FLUOROGENICO MEDIANTE EL DISEÑO DE MATERIALES SENSORES AVANZADOS./ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Proyectos de Ingeniería - Departament de Projectes d'Enginyeria | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.conferencename | Eurosensors XXIII | es_ES |
dc.relation.conferencedate | September 06-09,2009 | es_ES |
dc.relation.conferenceplace | Lausane (Suiza) | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.proche.2009.07.081 | es_ES |
dc.description.upvformatpinicio | 325 | es_ES |
dc.description.upvformatpfin | 328 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 1 | es_ES |
dc.description.issue | 1 | es_ES |
dc.relation.pasarela | S\36311 | es_ES |
dc.contributor.funder | Ministerio de Educación y Ciencia | es_ES |
dc.contributor.funder | Universitat Politècnica de València | es_ES |