Mostrar el registro sencillo del ítem
dc.contributor.author | Gutiérrez, S. C. | es_ES |
dc.contributor.author | Meseguer, M. D. | es_ES |
dc.contributor.author | Bellera Sosa, Julio | es_ES |
dc.contributor.author | Folguera Arbas, Fernando | es_ES |
dc.date.accessioned | 2018-04-14T04:15:38Z | |
dc.date.available | 2018-04-14T04:15:38Z | |
dc.date.issued | 2013 | es_ES |
dc.identifier.issn | 1877-7058 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/100412 | |
dc.description.abstract | [EN] This article studies tridimensional adjustment of Cr-Co fixed partial dentures obtained with different manufacturing processes (CNC milling, laser metal sintering and lost-wax), making a special point of the most critical adjustment, the marginal fit. A model was obtained with the impression taken in the oral cavity of a patient. This model was digitalized, and serves as the reference for manufacturing fixed partial dentures using different manufacturing processes. This article proposes a method of comparing the original model with the fixed partial dentures. This comparison was carried out using commercial software, allowing dental technicians to obtain information which can identify errors and geometric discrepancies before the fixed partial denture is implanted in the patient. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Procedia Engineering | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Fixed partial dentures | es_ES |
dc.subject | Marginal fit | es_ES |
dc.subject | three-dimensional analysis | es_ES |
dc.subject | Computer-aided analysis | es_ES |
dc.subject.classification | INGENIERIA DE LOS PROCESOS DE FABRICACION | es_ES |
dc.title | Analysis of variability in the manufacture of Cr-Co fixed partial dentures by geometric comparison | es_ES |
dc.type | Artículo | es_ES |
dc.type | Comunicación en congreso | es_ES |
dc.identifier.doi | 10.1016/j.proeng.2013.08.270 | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Mecánica y de Materiales - Departament d'Enginyeria Mecànica i de Materials | es_ES |
dc.description.bibliographicCitation | Gutiérrez, SC.; Meseguer, MD.; Bellera Sosa, J.; Folguera Arbas, F. (2013). Analysis of variability in the manufacture of Cr-Co fixed partial dentures by geometric comparison. Procedia Engineering. 63:481-488. doi:10.1016/j.proeng.2013.08.270 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.conferencename | 5th Manufacturing Engineering Society International Conference (MESIC 2013) | es_ES |
dc.relation.conferencedate | June 26-28, 2013 | es_ES |
dc.relation.conferenceplace | Zaragoza, Spain | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.proeng.2013.08.270 | es_ES |
dc.description.upvformatpinicio | 481 | es_ES |
dc.description.upvformatpfin | 488 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 63 | es_ES |
dc.relation.pasarela | S\254607 | es_ES |