Mostrar el registro sencillo del ítem
dc.contributor.author | Torrella Alcaraz, Enrique | es_ES |
dc.contributor.author | Cabello, R. | es_ES |
dc.contributor.author | Sanchez, D. | es_ES |
dc.contributor.author | Larumbe, J.A. | es_ES |
dc.contributor.author | Llopis, R. | es_ES |
dc.date.accessioned | 2018-04-19T12:41:29Z | |
dc.date.available | 2018-04-19T12:41:29Z | |
dc.date.issued | 2010 | es_ES |
dc.identifier.issn | 0378-7788 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/100721 | |
dc.description.abstract | [EN] The European Regulation no 2037/2000 has banned manufacturing HCFC refrigerants from January 1st 2010, although its use is allowed up to 2015 if the fluids come from a recycling process. This situation creates the need for developing new working fluids to replace the HCFC in the refrigeration plants now in operation. Among all the HCFCs the R22 is the most widely used in a wide range of applications, especially in air conditioning. This work presents an on-site experimental study of the R22 replacement by two possible substitutes, the HFC-417A and the HFC-422D, in a water chiller in which the energy performance was evaluated. This chiller is part of the centralized HVAC system of a lecture room building at the Jaume 1 University of Castellon, Spain. This communication compares and analyses main operation parameters of the chiller when operating with each refrigerant in real conditions. (C) 2010 Elsevier B.V. All rights reserved. | es_ES |
dc.description.sponsorship | The authors would like to thank the Technical Office of Projects and Buildings (OTOP) of the Jaume 1 University and the maintenance company AGE VAL for its collaboration with the present work. Furthermore, the authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) for the economic support. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Energy and Buildings | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | HCFC-22 | es_ES |
dc.subject | HFC-422D | es_ES |
dc.subject | HFC-417A | es_ES |
dc.subject | Replacement | es_ES |
dc.subject | Drop-in | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.title | On-site study of HCFC-22 substitution for HFC non-azeotropic blends (R417A, R422D) on a water chiller of a centralized HVAC system | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.enbuild.2010.04.001 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//CTM2008-06468-C02-01/ES/ESTRATEGIA DE AHORRO Y EFICIENCIA ENERGETICA EN PRODUCCION DE FRIO POR COMPRESION CON REFRIGERANTES HFC/ | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.description.bibliographicCitation | Torrella Alcaraz, E.; Cabello, R.; Sanchez, D.; Larumbe, J.; Llopis, R. (2010). On-site study of HCFC-22 substitution for HFC non-azeotropic blends (R417A, R422D) on a water chiller of a centralized HVAC system. Energy and Buildings. 42(9):1561-1566. https://doi.org/10.1016/j.enbuild.2010.04.001 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.enbuild.2010.04.001 | es_ES |
dc.description.upvformatpinicio | 1561 | es_ES |
dc.description.upvformatpfin | 1566 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 42 | es_ES |
dc.description.issue | 9 | es_ES |
dc.relation.pasarela | S\39684 | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |