dc.description.abstract | [EN] As a result of the ban of the CFC fluids in 2000 and the future limitation of HCFC fluids, which manufacture limit is the year 2010, refrigerant producers have been working to develop different mixtures, mainly based on HFC fluids, which emulate the properties of the former refrigerants used in refrigeration plants. At the moment, the HFC-404A and the HFC-507A are the more widely used fluids in Europe as replacement of the CFC-502 in plants operating at low temperatures. This work presents the experimental evaluation, from an energy point of view, of both refrigerants in the same refrigeration plant, which corresponds to a double-stage vapour compression plant driven by a compound compressor. The characterization was made for an evaporating temperature range between ¿36 and ¿20 °C for a constant condensing temperature of 40 °C. | es_ES |
dc.description.sponsorship | The authors are indebted to 'Fundacion Caixa Castello-Bancaixa' (P1.1B2008-12) and to the 'Ministerio de Medioambiente y Medio Rural y Marino' (200800050084716) for the support given to the present study. | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Applied Energy | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | HFC-404A | es_ES |
dc.subject | HFC-507A | es_ES |
dc.subject | Compound compressor | es_ES |
dc.subject | RefrigerantDouble-stage | es_ES |
dc.subject.classification | MAQUINAS Y MOTORES TERMICOS | es_ES |
dc.title | Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.apenergy.2009.10.020 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MARM//200800050084716/ES/RNCO2: NUEVAS TECNOLOGÍAS FRIGORÍFICAS DE COMPRESIÓN DE VAPOR CON UTILIZACIÓN DEL REFRIGERANTE NATURALL CO2 EN SUSTITUCIÓN DE LOS ACTUALES HFC/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UJI//P1·1B2008-12/ | |
dc.rights.accessRights | Cerrado | es_ES |
dc.description.bibliographicCitation | Llopis, R.; Torrella Alcaraz, E.; Cabello, R.; Sanchez, D. (2010). Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant. Applied Energy. 87(5):1546-1553. https://doi.org/10.1016/j.apenergy.2009.10.020 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.apenergy.2009.10.020 | es_ES |
dc.description.upvformatpinicio | 1546 | es_ES |
dc.description.upvformatpfin | 1553 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 87 | es_ES |
dc.description.issue | 5 | es_ES |
dc.relation.pasarela | S\39680 | es_ES |
dc.contributor.funder | Ministerio de Medio Ambiente y Medio Rural y Marino | es_ES |
dc.contributor.funder | Fundació Caixa Castelló - Bancaixa | |
dc.contributor.funder | Universitat Jaume I | es_ES |