dc.contributor.author | Quesada, Rita | es_ES |
dc.contributor.author | Poves, Ignasi | es_ES |
dc.contributor.author | Iglesias, Mar | es_ES |
dc.contributor.author | Berjano, Enrique | es_ES |
dc.contributor.author | Grande, Luis | es_ES |
dc.contributor.author | Burdío, Fernando | es_ES |
dc.date.accessioned | 2018-05-21T04:27:45Z | |
dc.date.available | 2018-05-21T04:27:45Z | |
dc.date.issued | 2016 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/102327 | |
dc.description.abstract | [EN] Background Although radiofrequency-assisted devices have sometimes been used in partial splenectomy, this is not a common technique. This report describes the first case of laparoscopic partial splenectomy using an RF-assisted device (Coolinside) which allows both coagulation and transection of the parenchyma and eventually the protective coagulation of the remnant side. Case presentation A 27-year-old woman was found to have a giant hydatic cyst measuring 12.0¿×¿14.0¿×¿16.6 cm that mainly occupied the lower pole of the spleen and retroperitoneal space. The patient underwent a laparoscopic partial splenectomy using an RF-based device designed to accomplish both the coagulation and dissection of the splenic tissue. The estimated blood loss was less than 200 mL. Conclusions Even though RF ablation has traditionally been used for hepatic parenchymal transection, it seems equally suited to partial splenectomy. This device seems to provide good results, minimizing blood loss during partial splenectomy; however, randomized trials will be necessary to see if the results are superior to those of other techniques. | es_ES |
dc.description.sponsorship | This work was partially supported by the Spanish“Programa Estatal deInvestigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R and TEC2014-52383-C3-3-R). | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Springer (Biomed Central Ltd.) | es_ES |
dc.relation.ispartof | Surgical Case Reports | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Giant splenic cyst | es_ES |
dc.subject | Laparoscopic splenectomy | es_ES |
dc.subject | Radiofrequency | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | Laparoscopic partial splenectomy for giant cyst using a radiofrequency-assisted device: a case report | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1186/s40792-016-0206-x | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//TEC2014-52383-C3-1-R/ES/TECNOLOGIAS BASADAS EN ENERGIA DE RADIOFRECUENCIA Y MICROONDAS PARA CIRUGIA DE MINIMA INVASION/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//TEC2014-52383-C3-3-R/ES/VALORACION EXPERIMENTAL IN VIVO DE TECNOLOGIAS BASADAS EN ENERGIA ELECTROMAGNETICA PARA CIRUGIA DE MINIMA INVASION/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.description.bibliographicCitation | Quesada, R.; Poves, I.; Iglesias, M.; Berjano, E.; Grande, L.; Burdío, F. (2016). Laparoscopic partial splenectomy for giant cyst using a radiofrequency-assisted device: a case report. Surgical Case Reports. 2(82):1-4. https://doi.org/10.1186/s40792-016-0206-x | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1186/s40792-016-0206-x | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 4 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 2 | es_ES |
dc.description.issue | 82 | es_ES |
dc.identifier.eissn | 2198-7793 | es_ES |
dc.identifier.pmid | 27558744 | en_EN |
dc.identifier.pmcid | PMC4996810 | en_EN |
dc.relation.pasarela | S\316604 | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |
dc.description.references | Bong JJ, Kumar R, Spalding D. A novel technique of partial splenectomy using radiofrequency ablation. J Gastrointest Surg. 2011;15(2):371–2. | es_ES |
dc.description.references | Burdio F, et al. A new single-instrument technique for parenchyma division and hemostasis in liver resection: a clinical feasibility study. Am J Surg. 2010;200(6):e75–80. | es_ES |
dc.description.references | Stella M, et al. Conservative management of a spleen trauma using radiofrequency. Ann Ital Chir. 2005;76(6):559–61. | es_ES |
dc.description.references | Jarry J, et al. Video. Radiofrequency fulguration of the spleen under laparoscopy to stop iatrogenic hemorrhage. Surg Endosc. 2012;26(4):1163–4. | es_ES |
dc.description.references | Li Y, et al. Laparoscopic radiofrequency ablation for traumatic splenic rupture. J Surg Res. 2013;185(2):711–6. | es_ES |
dc.description.references | Wu Y, et al. Application of radiofrequency ablation for splenic preservation. J Surg Res. 2015;193(2):781–7. | es_ES |
dc.description.references | Habib NA, et al. How we do a bloodless partial splenectomy. Am J Surg. 2003;186(2):164–6. | es_ES |
dc.description.references | Karadayi K, Turan M, Sen M. A new technique for partial splenectomy with radiofrequency technology. Surg Laparosc Endosc Percutan Tech. 2011;21(5):358–61. | es_ES |
dc.description.references | Liese J, et al. Partial spleen resection with a radiofrequency needle device—a pilot study. Langenbecks Arch Surg. 2013;398(3):449–54. | es_ES |
dc.description.references | De Greef E, et al. Partial laparoscopic splenectomy for splenic abscess because of Salmonella infection: a case report. J Pediatr Surg. 2008;43(5):E35–8. | es_ES |
dc.description.references | Gumbs AA, et al. Laparoscopic partial splenectomy using radiofrequency ablation. J Laparoendosc Adv Surg Tech A. 2008;18(4):611–3. | es_ES |
dc.description.references | Khelif K, et al. Laparoscopic partial splenectomy using radiofrequency ablation for nonparasitic splenic cysts in two children. J Laparoendosc Adv Surg Tech A. 2006;16(4):414–7. | es_ES |
dc.description.references | Itamoto T, et al. Radiofrequency-assisted partial splenectomy with a new and simple device. Am J Surg. 2006;192(2):252–4. | es_ES |
dc.description.references | Velanovich V, Weaver M. Partial splenectomy using a coupled saline-radiofrequency hemostatic device. Am J Surg. 2003;185(1):66–8. | es_ES |
dc.description.references | Dudi-Venkata NN, et al. Laparoscopic partial splenectomy performed by monopolar saline-cooled radiofrequency coagulation. J Laparoendosc Adv Surg Tech A. 2014;24(7):502–5. | es_ES |
dc.description.references | Burdio F, et al. A radiofrequency-assisted device for bloodless rapid transection of the liver: a comparative study in a pig liver model. Eur J Surg Oncol. 2008;34(5):599–605. | es_ES |
dc.description.references | Navarro A, et al. Laparoscopic blood-saving liver resection using a new radiofrequency-assisted device: preliminary report of an in vivo study with pig liver. Surg Endosc. 2008;22(5):1384–91. | es_ES |