- -

Development of a Ta/TaN/TaNx(Ag)y/TaN nanocomposite coating system and bio-response study for biomedical applications

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Development of a Ta/TaN/TaNx(Ag)y/TaN nanocomposite coating system and bio-response study for biomedical applications

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Echavarria, Aida M. es_ES
dc.contributor.author Rico Tortosa, Patricia María es_ES
dc.contributor.author Gómez Ribelles, José Luís es_ES
dc.contributor.author Pacha-Olivenza, Miguel A. es_ES
dc.contributor.author Fernandez-Calderon, Maria-Coronada es_ES
dc.contributor.author Bejarano-G, Gilberto es_ES
dc.date.accessioned 2018-05-26T04:18:56Z
dc.date.available 2018-05-26T04:18:56Z
dc.date.issued 2017 es_ES
dc.identifier.issn 0042-207X es_ES
dc.identifier.uri http://hdl.handle.net/10251/102685
dc.description.abstract [EN] TaN(Ag) composited coatings are being investigated to improve biocompatibility of different biomedical devices due to the mechanical and chemical stability of TaN and bactericidal effect of silver nanoparticles. However, controlling the size, density, shape and especially the release of silver ions (Ag) into the surrounding medium becomes a challenge, since elevated levels of Ag could be cytotoxic. The aim of this work is to design and develop a new Ta/TaN/TaNx(Ag)y/TaN coating system, deposited by unbalanced DC magnetron sputtering technique, presenting an adequate balance between biocompatibility and bactericidal effect for potential applications in biomedical field. For this purpose, four different coating systems were deposited on 316 L stainless steel and silicon (100) samples applying a bias voltage of ¿30, ¿60, ¿90 and ¿120 V during the deposition of the top layer of TaN to vary its density. This manufacturing strategy allowed controlling the diffusion of silver nanoparticles to the coating surface and the release kinetics of silver ions in simulated body fluid (SBF). Biologic characterization has been performed with MC3T3-E1 pre-osteoblastic cells in terms of cell adhesion and long-term differentiation. Additionally, the adhesion and biofilm formation of the bacteria Streptococcus sanguinis strain in the deposited coating systems of Ta/TaN/TaNx(Ag)y/TaN were analyzed. The results indicated an improvement of cell adhesion and differentiation of the composited coating deposited with a bias of ¿30 V compared to other coatings. Concordantly, this coating showed the lowest bacterial adhesion and biofilm formation, representing an attractive and suitable composited material for biomedical applications. es_ES
dc.description.sponsorship The technical support from the Spanish Ministry of Economy and Competitiveness (MINECO) (through the MAT2015-69315-C3-1-R) and FEDER funds project are acknowledged. CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program, CIBER Actions and financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. en_EN
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Vacuum es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Biocompatible coatings es_ES
dc.subject Ag nanoparticles es_ES
dc.subject Biomedical devices es_ES
dc.subject Magnetron sputtering es_ES
dc.subject MC3T3 preosteoblastic cells es_ES
dc.subject Streptococcus sanguinis es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.title Development of a Ta/TaN/TaNx(Ag)y/TaN nanocomposite coating system and bio-response study for biomedical applications es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.vacuum.2017.08.020 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//MAT2015-69315-C3-1-R/ES/SOPORTES CELULARES BIODEGRADABLES CARGADOS CON IONES BIOACTIVOS PARA REGENERACION MUSCULAR/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Centro de Biomateriales e Ingeniería Tisular - Centre de Biomaterials i Enginyeria Tissular es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada es_ES
dc.description.bibliographicCitation Echavarria, AM.; Rico Tortosa, PM.; Gómez Ribelles, JL.; Pacha-Olivenza, MA.; Fernandez-Calderon, M.; Bejarano-G, G. (2017). Development of a Ta/TaN/TaNx(Ag)y/TaN nanocomposite coating system and bio-response study for biomedical applications. Vacuum. 145:55-67. https://doi.org/10.1016/j.vacuum.2017.08.020 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://dx.doi.org/10.1016/j.vacuum.2017.08.020 es_ES
dc.description.upvformatpinicio 55 es_ES
dc.description.upvformatpfin 67 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 145 es_ES
dc.relation.pasarela S\342729 es_ES
dc.contributor.funder Ministerio de Economía, Industria y Competitividad es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem