Mostrar el registro sencillo del ítem
dc.contributor.author | Artigas, Jose M. | es_ES |
dc.contributor.author | Garcia-Domene, M. Carmen | es_ES |
dc.contributor.author | Navea, Amparo | es_ES |
dc.contributor.author | Botella Asuncion, Pablo | es_ES |
dc.contributor.author | Fernandez, Eduardo | es_ES |
dc.date.accessioned | 2018-06-08T04:20:44Z | |
dc.date.available | 2018-06-08T04:20:44Z | |
dc.date.issued | 2017 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/103603 | |
dc.description.abstract | [EN] To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties. | es_ES |
dc.description.sponsorship | Project IPT-2012-0574-300000 (Spain) and AJL Ophthalmic S.A. (Vitoria, Spain). | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Optical Society of America | es_ES |
dc.relation.ispartof | Biomedical Optics Express | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.title | Intra-ocular lens optical changes resulting from the loading of dexamethasone | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1364/BOE.8.004621 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//IPT-2012-0574-300000/ES/Desarrollo de una nueva generación de lentes intraoculares multifuncionales(HORUS)/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario Mixto de Tecnología Química - Institut Universitari Mixt de Tecnologia Química | es_ES |
dc.description.bibliographicCitation | Artigas, JM.; Garcia-Domene, MC.; Navea, A.; Botella Asuncion, P.; Fernandez, E. (2017). Intra-ocular lens optical changes resulting from the loading of dexamethasone. Biomedical Optics Express. 8(10):4621-4628. https://doi.org/10.1364/BOE.8.004621 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1364/BOE.8.004621 | es_ES |
dc.description.upvformatpinicio | 4621 | es_ES |
dc.description.upvformatpfin | 4628 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 8 | es_ES |
dc.description.issue | 10 | es_ES |
dc.identifier.eissn | 2156-7085 | es_ES |
dc.relation.pasarela | S\358642 | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |
dc.contributor.funder | European Regional Development Fund | |
dc.description.references | Bai, H.-Q., Yao, L., Meng, X.-X., Wang, Y.-X., & Wang, D.-B. (2011). Visual Outcome following Intraocular Foreign Bodies: A Retrospective Review of 5-Year Clinical Experience. European Journal of Ophthalmology, 21(1), 98-103. doi:10.5301/ejo.2010.2210 | es_ES |
dc.description.references | Jefferis, J. M., Mosimann, U. P., & Clarke, M. P. (2010). Cataract and cognitive impairment: a review of the literature. British Journal of Ophthalmology, 95(1), 17-23. doi:10.1136/bjo.2009.165902 | es_ES |
dc.description.references | Garty, S., Shirakawa, R., Warsen, A., Anderson, E. M., Noble, M. L., Bryers, J. D., … Shen, T. T. (2011). Sustained Antibiotic Release from an Intraocular Lens–Hydrogel Assembly for Cataract Surgery. Investigative Opthalmology & Visual Science, 52(9), 6109. doi:10.1167/iovs.10-6071 | es_ES |
dc.description.references | Kugelberg, M., Shafiei, K., van der Ploeg, I., & Zetterström, C. (2010). Intraocular lens as a drug delivery system for dexamethasone. Acta Ophthalmologica, 88(2), 241-244. doi:10.1111/j.1755-3768.2008.01419.x | es_ES |
dc.description.references | González-Chomón, C., Concheiro, A., & Alvarez-Lorenzo, C. (2011). Drug-Eluting Intraocular Lenses. Materials, 4(11), 1927-1940. doi:10.3390/ma4111927 | es_ES |
dc.description.references | Liu, Y.-C., Wong, T. T., & Mehta, J. S. (2013). Intraocular lens as a drug delivery reservoir. Current Opinion in Ophthalmology, 24(1), 53-59. doi:10.1097/icu.0b013e32835a93fc | es_ES |
dc.description.references | Masmoudi, Y., Ben Azzouk, L., Forzano, O., Andre, J.-M., & Badens, E. (2011). Supercritical impregnation of intraocular lenses. The Journal of Supercritical Fluids, 60, 98-105. doi:10.1016/j.supflu.2011.08.014 | es_ES |
dc.description.references | Manju, S., & Kunnatheeri, S. (2010). Layer-by-Layer modification of Poly (methyl methacrylate) intra ocular lens: Drug delivery applications. Pharmaceutical Development and Technology, 15(4), 379-385. doi:10.3109/10837450903262025 | es_ES |
dc.description.references | Bouledjouidja, A., Masmoudi, Y., Sergent, M., Trivedi, V., Meniai, A., & Badens, E. (2016). Drug loading of foldable commercial intraocular lenses using supercritical impregnation. International Journal of Pharmaceutics, 500(1-2), 85-99. doi:10.1016/j.ijpharm.2016.01.016 | es_ES |
dc.description.references | Kleinmann, G., Apple, D. J., Chew, J., Stevens, S., Hunter, B., Larson, S., … Olson, R. J. (2006). Hydrophilic acrylic intraocular lens as a drug-delivery system: Pilot study. Journal of Cataract & Refractive Surgery, 32(4), 652-654. doi:10.1016/j.jcrs.2006.01.038 | es_ES |
dc.description.references | Artigas, J. M., Menezo, J. L., Peris, C., Felipe, A., & Díaz-Llopis, M. (2007). Image quality with multifocal intraocular lenses and the effect of pupil size. Journal of Cataract & Refractive Surgery, 33(12), 2111-2117. doi:10.1016/j.jcrs.2007.07.035 | es_ES |
dc.description.references | Kawamorita, T., & Uozato, H. (2005). Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro. Journal of Cataract & Refractive Surgery, 31(12), 2379-2385. doi:10.1016/j.jcrs.2005.10.024 | es_ES |
dc.description.references | Rawer, R., Stork, W., Spraul, C. W., & Lingenfelder, C. (2005). Imaging quality of intraocular lenses. Journal of Cataract & Refractive Surgery, 31(8), 1618-1631. doi:10.1016/j.jcrs.2005.01.033 | es_ES |
dc.description.references | Pimenta, A. F. R., Ascenso, J., Fernandes, J. C. S., Colaço, R., Serro, A. P., & Saramago, B. (2016). Controlled drug release from hydrogels for contact lenses: Drug partitioning and diffusion. International Journal of Pharmaceutics, 515(1-2), 467-475. doi:10.1016/j.ijpharm.2016.10.047 | es_ES |
dc.description.references | Artigas, J. M., Felipe, A., Navea, A., Artigas, C., & García-Domene, M. C. (2011). Spectral Transmittance of Intraocular Lenses under Natural and Artificial Illumination. Ophthalmology, 118(1), 3-8. doi:10.1016/j.ophtha.2010.06.023 | es_ES |
dc.description.references | García-Domene, M. C., Díez-Ajenjo, M. A., Peris-Martínez, C., Navea, A., & Artigas, J. M. (2015). A rapid method for measuring intraocular lens power in vitro with a focimeter. Experimental Eye Research, 140, 190-192. doi:10.1016/j.exer.2015.09.009 | es_ES |
dc.description.references | Artigas, J. M., Peris, C., Felipe, A., Menezo, J. L., Sánchez-Cortina, I., & López-Gil, N. (2009). Modulation transfer function: Rigid versus foldable phakic intraocular lenses. Journal of Cataract & Refractive Surgery, 35(4), 747-752. doi:10.1016/j.jcrs.2008.12.020 | es_ES |
dc.description.references | Peris-Martínez, C., Artigas, J. M., Sánchez-Cortina, I., Felipe, A., Díez-Ajenjo, A., & Menezo, J. L. (2009). Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens. Journal of Cataract & Refractive Surgery, 35(11), 1911-1917. doi:10.1016/j.jcrs.2009.05.054 | es_ES |
dc.description.references | Felipe, A., Pastor, F., Artigas, J. M., Diez-Ajenjo, A., Gené, A., & Menezo, J. L. (2010). Correlation between optics quality of multifocal intraocular lenses and visual acuity. Journal of Cataract & Refractive Surgery, 36(4), 557-562. doi:10.1016/j.jcrs.2009.10.046 | es_ES |
dc.description.references | Alarcon, A., Canovas, C., Rosen, R., Weeber, H., Tsai, L., Hileman, K., & Piers, P. (2016). Preclinical metrics to predict through-focus visual acuity for pseudophakic patients. Biomedical Optics Express, 7(5), 1877. doi:10.1364/boe.7.001877 | es_ES |