Intra-ocular lens optical changes resulting from the loading of dexamethasone

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Intra-ocular lens optical changes resulting from the loading of dexamethasone

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Artigas, Jose M. es_ES
dc.contributor.author Garcia-Domene, M. Carmen es_ES
dc.contributor.author Navea, Amparo es_ES
dc.contributor.author Botella Asuncion, Pablo es_ES
dc.contributor.author Fernandez, Eduardo es_ES
dc.date.accessioned 2018-06-08T04:20:44Z
dc.date.available 2018-06-08T04:20:44Z
dc.date.issued 2017 es_ES
dc.identifier.uri http://hdl.handle.net/10251/103603
dc.description.abstract [EN] To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties. es_ES
dc.description.sponsorship Project IPT-2012-0574-300000 (Spain) and AJL Ophthalmic S.A. (Vitoria, Spain). es_ES
dc.language Inglés es_ES
dc.publisher Optical Society of America es_ES
dc.relation.ispartof Biomedical Optics Express es_ES
dc.rights Reconocimiento (by) es_ES
dc.title Intra-ocular lens optical changes resulting from the loading of dexamethasone es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1364/BOE.8.004621 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//IPT-2012-0574-300000/ES/Desarrollo de una nueva generación de lentes intraoculares multifuncionales(HORUS)/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Instituto Universitario Mixto de Tecnología Química - Institut Universitari Mixt de Tecnologia Química es_ES
dc.description.bibliographicCitation Artigas, JM.; Garcia-Domene, MC.; Navea, A.; Botella Asuncion, P.; Fernandez, E. (2017). Intra-ocular lens optical changes resulting from the loading of dexamethasone. Biomedical Optics Express. 8(10):4621-4628. https://doi.org/10.1364/BOE.8.004621 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1364/BOE.8.004621 es_ES
dc.description.upvformatpinicio 4621 es_ES
dc.description.upvformatpfin 4628 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 8 es_ES
dc.description.issue 10 es_ES
dc.identifier.eissn 2156-7085 es_ES
dc.relation.pasarela S\358642 es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.contributor.funder European Regional Development Fund
dc.description.references Bai, H.-Q., Yao, L., Meng, X.-X., Wang, Y.-X., & Wang, D.-B. (2011). Visual Outcome following Intraocular Foreign Bodies: A Retrospective Review of 5-Year Clinical Experience. European Journal of Ophthalmology, 21(1), 98-103. doi:10.5301/ejo.2010.2210 es_ES
dc.description.references Jefferis, J. M., Mosimann, U. P., & Clarke, M. P. (2010). Cataract and cognitive impairment: a review of the literature. British Journal of Ophthalmology, 95(1), 17-23. doi:10.1136/bjo.2009.165902 es_ES
dc.description.references Garty, S., Shirakawa, R., Warsen, A., Anderson, E. M., Noble, M. L., Bryers, J. D., … Shen, T. T. (2011). Sustained Antibiotic Release from an Intraocular Lens–Hydrogel Assembly for Cataract Surgery. Investigative Opthalmology & Visual Science, 52(9), 6109. doi:10.1167/iovs.10-6071 es_ES
dc.description.references Kugelberg, M., Shafiei, K., van der Ploeg, I., & Zetterström, C. (2010). Intraocular lens as a drug delivery system for dexamethasone. Acta Ophthalmologica, 88(2), 241-244. doi:10.1111/j.1755-3768.2008.01419.x es_ES
dc.description.references González-Chomón, C., Concheiro, A., & Alvarez-Lorenzo, C. (2011). Drug-Eluting Intraocular Lenses. Materials, 4(11), 1927-1940. doi:10.3390/ma4111927 es_ES
dc.description.references Liu, Y.-C., Wong, T. T., & Mehta, J. S. (2013). Intraocular lens as a drug delivery reservoir. Current Opinion in Ophthalmology, 24(1), 53-59. doi:10.1097/icu.0b013e32835a93fc es_ES
dc.description.references Masmoudi, Y., Ben Azzouk, L., Forzano, O., Andre, J.-M., & Badens, E. (2011). Supercritical impregnation of intraocular lenses. The Journal of Supercritical Fluids, 60, 98-105. doi:10.1016/j.supflu.2011.08.014 es_ES
dc.description.references Manju, S., & Kunnatheeri, S. (2010). Layer-by-Layer modification of Poly (methyl methacrylate) intra ocular lens: Drug delivery applications. Pharmaceutical Development and Technology, 15(4), 379-385. doi:10.3109/10837450903262025 es_ES
dc.description.references Bouledjouidja, A., Masmoudi, Y., Sergent, M., Trivedi, V., Meniai, A., & Badens, E. (2016). Drug loading of foldable commercial intraocular lenses using supercritical impregnation. International Journal of Pharmaceutics, 500(1-2), 85-99. doi:10.1016/j.ijpharm.2016.01.016 es_ES
dc.description.references Kleinmann, G., Apple, D. J., Chew, J., Stevens, S., Hunter, B., Larson, S., … Olson, R. J. (2006). Hydrophilic acrylic intraocular lens as a drug-delivery system: Pilot study. Journal of Cataract & Refractive Surgery, 32(4), 652-654. doi:10.1016/j.jcrs.2006.01.038 es_ES
dc.description.references Artigas, J. M., Menezo, J. L., Peris, C., Felipe, A., & Díaz-Llopis, M. (2007). Image quality with multifocal intraocular lenses and the effect of pupil size. Journal of Cataract & Refractive Surgery, 33(12), 2111-2117. doi:10.1016/j.jcrs.2007.07.035 es_ES
dc.description.references Kawamorita, T., & Uozato, H. (2005). Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro. Journal of Cataract & Refractive Surgery, 31(12), 2379-2385. doi:10.1016/j.jcrs.2005.10.024 es_ES
dc.description.references Rawer, R., Stork, W., Spraul, C. W., & Lingenfelder, C. (2005). Imaging quality of intraocular lenses. Journal of Cataract & Refractive Surgery, 31(8), 1618-1631. doi:10.1016/j.jcrs.2005.01.033 es_ES
dc.description.references Pimenta, A. F. R., Ascenso, J., Fernandes, J. C. S., Colaço, R., Serro, A. P., & Saramago, B. (2016). Controlled drug release from hydrogels for contact lenses: Drug partitioning and diffusion. International Journal of Pharmaceutics, 515(1-2), 467-475. doi:10.1016/j.ijpharm.2016.10.047 es_ES
dc.description.references Artigas, J. M., Felipe, A., Navea, A., Artigas, C., & García-Domene, M. C. (2011). Spectral Transmittance of Intraocular Lenses under Natural and Artificial Illumination. Ophthalmology, 118(1), 3-8. doi:10.1016/j.ophtha.2010.06.023 es_ES
dc.description.references García-Domene, M. C., Díez-Ajenjo, M. A., Peris-Martínez, C., Navea, A., & Artigas, J. M. (2015). A rapid method for measuring intraocular lens power in vitro with a focimeter. Experimental Eye Research, 140, 190-192. doi:10.1016/j.exer.2015.09.009 es_ES
dc.description.references Artigas, J. M., Peris, C., Felipe, A., Menezo, J. L., Sánchez-Cortina, I., & López-Gil, N. (2009). Modulation transfer function: Rigid versus foldable phakic intraocular lenses. Journal of Cataract & Refractive Surgery, 35(4), 747-752. doi:10.1016/j.jcrs.2008.12.020 es_ES
dc.description.references Peris-Martínez, C., Artigas, J. M., Sánchez-Cortina, I., Felipe, A., Díez-Ajenjo, A., & Menezo, J. L. (2009). Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens. Journal of Cataract & Refractive Surgery, 35(11), 1911-1917. doi:10.1016/j.jcrs.2009.05.054 es_ES
dc.description.references Felipe, A., Pastor, F., Artigas, J. M., Diez-Ajenjo, A., Gené, A., & Menezo, J. L. (2010). Correlation between optics quality of multifocal intraocular lenses and visual acuity. Journal of Cataract & Refractive Surgery, 36(4), 557-562. doi:10.1016/j.jcrs.2009.10.046 es_ES
dc.description.references Alarcon, A., Canovas, C., Rosen, R., Weeber, H., Tsai, L., Hileman, K., & Piers, P. (2016). Preclinical metrics to predict through-focus visual acuity for pseudophakic patients. Biomedical Optics Express, 7(5), 1877. doi:10.1364/boe.7.001877 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)