Mostrar el registro sencillo del ítem
dc.contributor.author | Martínez-Bisbal, M.Carmen | es_ES |
dc.contributor.author | Loeff, Edwin | es_ES |
dc.contributor.author | Olivas, Estela | es_ES |
dc.contributor.author | Carbó-Mestre, Noèlia | es_ES |
dc.contributor.author | Garcia Castillo, F. Javier | es_ES |
dc.contributor.author | López-Carrero, Javier | es_ES |
dc.contributor.author | Tormos, Isabel | es_ES |
dc.contributor.author | Tejadillos, Francisco José | es_ES |
dc.contributor.author | Berlanga, José Guillermo | es_ES |
dc.contributor.author | Martínez-Máñez, Ramón | es_ES |
dc.contributor.author | Alcañiz Fillol, Miguel | es_ES |
dc.contributor.author | Soto Camino, Juan | es_ES |
dc.date.accessioned | 2018-06-08T04:25:11Z | |
dc.date.available | 2018-06-08T04:25:11Z | |
dc.date.issued | 2017 | es_ES |
dc.identifier.issn | 1040-0397 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/103614 | |
dc.description.abstract | [EN] The use of a voltammetric electronic tongue for the quantitative analysis of quality parameters in influent wastewater from a wastewater treatment plant (WWTP) that treats domestic and industrial wastewater is proposed. The electronic voltammetric tongue consists of a set of four noble electrodes (iridium, rhodium, platinum and gold) housed inside a stainless steel cylinder. These noble metals have high durability and are low maintenance-demanding, as required for developing future automated equipment. A pulse voltammetry study was conducted in 35 wastewater samples to determine ammonia (NH4+-N), nitrates (NO3--N), total phosphate (tot-P), soluble chemical oxygen demand (CODs) and conductivity. These parameters were also determined in these samples by routine analytical methods in the WWTP laboratory. A partial least squares (PLS) analysis was run to obtain a model to predict each parameter. Twenty-five samples were included in the calibration set and 10 in the validation set. Calibration and validation sets were selected randomly, except for the extreme values of each parameter, which were included in the calibration set. Variable selection was performed on the voltammetric data using Genetic Algorithms in the calibration data set for each parameter. The electronic tongue showed good predictive power to determine the concentrations of NH4+-N, NO3--N and tot-P and CODs. | es_ES |
dc.description.sponsorship | The financial support for this work was provided by the Spanish Ministry of Economy and Competitivity though Project e-TONGUE4WAT (IPT-2012-0069-310000) IN-NPACTO and by European Union FEDER funds. Financial support from the Spanish Government (Project MAT2012-38429-C04) and the Generalitat Valencia (Project PROMETEOII/2014/047) is also gratefully acknowledged. | |
dc.language | Inglés | es_ES |
dc.publisher | John Wiley & Sons | es_ES |
dc.relation.ispartof | Electroanalysis | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Wastewater | es_ES |
dc.subject | Voltammetric electronic tongue | es_ES |
dc.subject | Water quality control | es_ES |
dc.subject | Variable selection | es_ES |
dc.subject | Genetic algorithms | es_ES |
dc.subject.classification | QUIMICA INORGANICA | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.title | A voltammetric electronic tongue for the quantitative analysis of quality parameters in wastewater | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1002/elan.201600717 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//IPT-2012-0069-310000/ES/Desarrollo de sistemas basados en lenguas electrónicas para el control y monitorización del ciclo integral del agua. e-TONGUE4WAT/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2014%2F047/ES/Nuevas aproximaciones para el diseño de materiales de liberación controlada y la detección de compuestos peligrosos/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//MAT2012-38429-C04-04/ES/DESARROLLO DE NUEVOS SISTEMAS DE DETECCION Y ACCION BASADOS EN TECNOLOGIAS ELECTRONICAS Y MICROELECTRONICAS PARA SU APLICACION EN SISTEMAS DE LIBERACION Y DETECCION DE GASES/ / | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic | es_ES |
dc.description.bibliographicCitation | Martínez-Bisbal, M.; Loeff, E.; Olivas, E.; Carbó-Mestre, N.; Garcia Castillo, FJ.; López-Carrero, J.; Tormos, I.... (2017). A voltammetric electronic tongue for the quantitative analysis of quality parameters in wastewater. Electroanalysis. 29(4):1147-1153. https://doi.org/10.1002/elan.201600717 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://doi.org/10.1002/elan.201600717 | es_ES |
dc.description.upvformatpinicio | 1147 | es_ES |
dc.description.upvformatpfin | 1153 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 29 | es_ES |
dc.description.issue | 4 | es_ES |
dc.relation.pasarela | S\334558 | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |