dc.contributor.author | Sergio Pérez-López | es_ES |
dc.contributor.author | Fuster Escuder, José Miguel | es_ES |
dc.contributor.author | Candelas Valiente, Pilar | es_ES |
dc.contributor.author | Rubio Michavila, Constanza | es_ES |
dc.contributor.author | Belmar Ibáñez, Francisco | es_ES |
dc.date.accessioned | 2018-07-02T04:22:49Z | |
dc.date.available | 2018-07-02T04:22:49Z | |
dc.date.issued | 2018 | es_ES |
dc.identifier.issn | 0003-6951 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/104904 | |
dc.description.abstract | [EN] In this work, the distortion of the Fresnel Zone Plate focusing profile generated by a piston emitter in ultrasound applications is significantly reduced through the use of phase correction rings, which compensate the effect of the piston emitter radiation diagram. Both simulation and experimental results demonstrate the improvement achieved with this design method over the conventional case. | es_ES |
dc.description.sponsorship | This work has been supported by Spanish MINECO (TEC2015-70939-R). | en_EN |
dc.language | Inglés | es_ES |
dc.publisher | American Institute of Physics | es_ES |
dc.relation.ispartof | Applied Physics Letters | es_ES |
dc.rights | Reconocimiento (by) | es_ES |
dc.subject | Ultrasound | es_ES |
dc.subject | Piston | es_ES |
dc.subject | Fresnel | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.subject.classification | TEORIA DE LA SEÑAL Y COMUNICACIONES | es_ES |
dc.title | On the use of phase correction rings on Fresnel zone plates with ultrasound piston emitters | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1063/1.5036712 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//TEC2015-70939-R/ES/ESTRUCTURAS SUBWAVELENGTH PARA LA FOCALIZACION DE ULTRASONIDOS DE ALTA INTENSIDAD/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.description.bibliographicCitation | Sergio Pérez-López; Fuster Escuder, JM.; Candelas Valiente, P.; Rubio Michavila, C.; Belmar Ibáñez, F. (2018). On the use of phase correction rings on Fresnel zone plates with ultrasound piston emitters. Applied Physics Letters. (112):264102-1-264102-5. https://doi.org/10.1063/1.5036712 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1063/1.5036712 | es_ES |
dc.description.upvformatpinicio | 264102-1 | es_ES |
dc.description.upvformatpfin | 264102-5 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.issue | 112 | es_ES |
dc.relation.pasarela | S\364946 | es_ES |
dc.contributor.funder | Ministerio de Economía, Industria y Competitividad | es_ES |
dc.description.references | Tamura, S., Yasumoto, M., Kamijo, N., Takeuchi, A., Uesugi, K., Terada, Y., & Suzuki, Y. (2009). Quasi-blazed type multilayer zone plate for X-rays. Vacuum, 84(5), 578-580. doi:10.1016/j.vacuum.2009.03.037 | es_ES |
dc.description.references | Hristov, H. D., & Rodriguez, J. M. (2012). Design Equation for Multidielectric Fresnel Zone Plate Lens. IEEE Microwave and Wireless Components Letters, 22(11), 574-576. doi:10.1109/lmwc.2012.2224099 | es_ES |
dc.description.references | Yang, R., Tang, W., & Hao, Y. (2011). A broadband zone plate lens from transformation optics. Optics Express, 19(13), 12348. doi:10.1364/oe.19.012348 | es_ES |
dc.description.references | Calvo, D. C., Thangawng, A. L., Nicholas, M., & Layman, C. N. (2015). Thin Fresnel zone plate lenses for focusing underwater sound. Applied Physics Letters, 107(1), 014103. doi:10.1063/1.4926607 | es_ES |
dc.description.references | Stout-Grandy, S. M., Petosa, A., Minin, I. V., Minin, O. V., & Wight, J. (2006). A Systematic Study of Varying Reference Phase in the Design of Circular Fresnel Zone Plate Antennas. IEEE Transactions on Antennas and Propagation, 54(12), 3629-3637. doi:10.1109/tap.2006.886552 | es_ES |
dc.description.references | Fuster, J., Candelas, P., Castiñeira-Ibáñez, S., Pérez-López, S., & Rubio, C. (2017). Analysis of Fresnel Zone Plates Focusing Dependence on Operating Frequency. Sensors, 17(12), 2809. doi:10.3390/s17122809 | es_ES |
dc.description.references | Kennedy, J. E., Wu, F., ter Haar, G. R., Gleeson, F. V., Phillips, R. R., Middleton, M. R., & Cranston, D. (2004). High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics, 42(1-9), 931-935. doi:10.1016/j.ultras.2004.01.089 | es_ES |
dc.description.references | Suo, D., Jin, Z., Jiang, X., Dayton, P. A., & Jing, Y. (2017). Microbubble mediated dual-frequency high intensity focused ultrasound thrombolysis: AnIn vitrostudy. Applied Physics Letters, 110(2), 023703. doi:10.1063/1.4973857 | es_ES |
dc.description.references | Suo, D., Guo, S., Lin, W., Jiang, X., & Jing, Y. (2015). Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: anin vitrostudy. Physics in Medicine and Biology, 60(18), 7403-7418. doi:10.1088/0031-9155/60/18/7403 | es_ES |
dc.description.references | Shen, C., Xu, J., Fang, N. X., & Jing, Y. (2014). Anisotropic Complementary Acoustic Metamaterial for Canceling out Aberrating Layers. Physical Review X, 4(4). doi:10.1103/physrevx.4.041033 | es_ES |
dc.description.references | Carovac, A., Smajlovic, F., & Junuzovic, D. (2011). Application of Ultrasound in Medicine. Acta Informatica Medica, 19(3), 168. doi:10.5455/aim.2011.19.168-171 | es_ES |
dc.description.references | Xie, Y., Shen, C., Wang, W., Li, J., Suo, D., Popa, B.-I., … Cummer, S. A. (2016). Acoustic Holographic Rendering with Two-dimensional Metamaterial-based Passive Phased Array. Scientific Reports, 6(1). doi:10.1038/srep35437 | es_ES |
dc.description.references | Estrada, H., Uris, A., & Meseguer, F. (2012). Acoustic radiation efficiency of a periodically corrugated rigid piston. Applied Physics Letters, 101(10), 104103. doi:10.1063/1.4748868 | es_ES |
dc.description.references | Martins, M., Correia, V., Cabral, J. M., Lanceros-Mendez, S., & Rocha, J. G. (2012). Optimization of piezoelectric ultrasound emitter transducers for underwater communications. Sensors and Actuators A: Physical, 184, 141-148. doi:10.1016/j.sna.2012.06.008 | es_ES |
dc.description.references | Luong, T.-D., Hies, T., & Ohl, C.-D. (2016). A compact time reversal emitter-receiver based on a leaky random cavity. Scientific Reports, 6(1). doi:10.1038/srep36096 | es_ES |
dc.description.references | Smith, D. R., Gowda, V. R., Yurduseven, O., Larouche, S., Lipworth, G., Urzhumov, Y., & Reynolds, M. S. (2017). An analysis of beamed wireless power transfer in the Fresnel zone using a dynamic, metasurface aperture. Journal of Applied Physics, 121(1), 014901. doi:10.1063/1.4973345 | es_ES |