On the use of phase correction rings on Fresnel zone plates with ultrasound piston emitters

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

On the use of phase correction rings on Fresnel zone plates with ultrasound piston emitters

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Sergio Pérez-López es_ES
dc.contributor.author Fuster Escuder, José Miguel es_ES
dc.contributor.author Candelas Valiente, Pilar es_ES
dc.contributor.author Rubio Michavila, Constanza es_ES
dc.contributor.author Belmar Ibáñez, Francisco es_ES
dc.date.accessioned 2018-07-02T04:22:49Z
dc.date.available 2018-07-02T04:22:49Z
dc.date.issued 2018 es_ES
dc.identifier.issn 0003-6951 es_ES
dc.identifier.uri http://hdl.handle.net/10251/104904
dc.description.abstract [EN] In this work, the distortion of the Fresnel Zone Plate focusing profile generated by a piston emitter in ultrasound applications is significantly reduced through the use of phase correction rings, which compensate the effect of the piston emitter radiation diagram. Both simulation and experimental results demonstrate the improvement achieved with this design method over the conventional case. es_ES
dc.description.sponsorship This work has been supported by Spanish MINECO (TEC2015-70939-R). en_EN
dc.language Inglés es_ES
dc.publisher American Institute of Physics es_ES
dc.relation.ispartof Applied Physics Letters es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Ultrasound es_ES
dc.subject Piston es_ES
dc.subject Fresnel es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.subject.classification TEORIA DE LA SEÑAL Y COMUNICACIONES es_ES
dc.title On the use of phase correction rings on Fresnel zone plates with ultrasound piston emitters es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1063/1.5036712 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//TEC2015-70939-R/ES/ESTRUCTURAS SUBWAVELENGTH PARA LA FOCALIZACION DE ULTRASONIDOS DE ALTA INTENSIDAD/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Comunicaciones - Departament de Comunicacions es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.description.bibliographicCitation Sergio Pérez-López; Fuster Escuder, JM.; Candelas Valiente, P.; Rubio Michavila, C.; Belmar Ibáñez, F. (2018). On the use of phase correction rings on Fresnel zone plates with ultrasound piston emitters. Applied Physics Letters. (112):264102-1-264102-5. https://doi.org/10.1063/1.5036712 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1063/1.5036712 es_ES
dc.description.upvformatpinicio 264102-1 es_ES
dc.description.upvformatpfin 264102-5 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.issue 112 es_ES
dc.relation.pasarela S\364946 es_ES
dc.contributor.funder Ministerio de Economía, Industria y Competitividad es_ES
dc.description.references Tamura, S., Yasumoto, M., Kamijo, N., Takeuchi, A., Uesugi, K., Terada, Y., & Suzuki, Y. (2009). Quasi-blazed type multilayer zone plate for X-rays. Vacuum, 84(5), 578-580. doi:10.1016/j.vacuum.2009.03.037 es_ES
dc.description.references Hristov, H. D., & Rodriguez, J. M. (2012). Design Equation for Multidielectric Fresnel Zone Plate Lens. IEEE Microwave and Wireless Components Letters, 22(11), 574-576. doi:10.1109/lmwc.2012.2224099 es_ES
dc.description.references Yang, R., Tang, W., & Hao, Y. (2011). A broadband zone plate lens from transformation optics. Optics Express, 19(13), 12348. doi:10.1364/oe.19.012348 es_ES
dc.description.references Calvo, D. C., Thangawng, A. L., Nicholas, M., & Layman, C. N. (2015). Thin Fresnel zone plate lenses for focusing underwater sound. Applied Physics Letters, 107(1), 014103. doi:10.1063/1.4926607 es_ES
dc.description.references Stout-Grandy, S. M., Petosa, A., Minin, I. V., Minin, O. V., & Wight, J. (2006). A Systematic Study of Varying Reference Phase in the Design of Circular Fresnel Zone Plate Antennas. IEEE Transactions on Antennas and Propagation, 54(12), 3629-3637. doi:10.1109/tap.2006.886552 es_ES
dc.description.references Fuster, J., Candelas, P., Castiñeira-Ibáñez, S., Pérez-López, S., & Rubio, C. (2017). Analysis of Fresnel Zone Plates Focusing Dependence on Operating Frequency. Sensors, 17(12), 2809. doi:10.3390/s17122809 es_ES
dc.description.references Kennedy, J. E., Wu, F., ter Haar, G. R., Gleeson, F. V., Phillips, R. R., Middleton, M. R., & Cranston, D. (2004). High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics, 42(1-9), 931-935. doi:10.1016/j.ultras.2004.01.089 es_ES
dc.description.references Suo, D., Jin, Z., Jiang, X., Dayton, P. A., & Jing, Y. (2017). Microbubble mediated dual-frequency high intensity focused ultrasound thrombolysis: AnIn vitrostudy. Applied Physics Letters, 110(2), 023703. doi:10.1063/1.4973857 es_ES
dc.description.references Suo, D., Guo, S., Lin, W., Jiang, X., & Jing, Y. (2015). Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: anin vitrostudy. Physics in Medicine and Biology, 60(18), 7403-7418. doi:10.1088/0031-9155/60/18/7403 es_ES
dc.description.references Shen, C., Xu, J., Fang, N. X., & Jing, Y. (2014). Anisotropic Complementary Acoustic Metamaterial for Canceling out Aberrating Layers. Physical Review X, 4(4). doi:10.1103/physrevx.4.041033 es_ES
dc.description.references Carovac, A., Smajlovic, F., & Junuzovic, D. (2011). Application of Ultrasound in Medicine. Acta Informatica Medica, 19(3), 168. doi:10.5455/aim.2011.19.168-171 es_ES
dc.description.references Xie, Y., Shen, C., Wang, W., Li, J., Suo, D., Popa, B.-I., … Cummer, S. A. (2016). Acoustic Holographic Rendering with Two-dimensional Metamaterial-based Passive Phased Array. Scientific Reports, 6(1). doi:10.1038/srep35437 es_ES
dc.description.references Estrada, H., Uris, A., & Meseguer, F. (2012). Acoustic radiation efficiency of a periodically corrugated rigid piston. Applied Physics Letters, 101(10), 104103. doi:10.1063/1.4748868 es_ES
dc.description.references Martins, M., Correia, V., Cabral, J. M., Lanceros-Mendez, S., & Rocha, J. G. (2012). Optimization of piezoelectric ultrasound emitter transducers for underwater communications. Sensors and Actuators A: Physical, 184, 141-148. doi:10.1016/j.sna.2012.06.008 es_ES
dc.description.references Luong, T.-D., Hies, T., & Ohl, C.-D. (2016). A compact time reversal emitter-receiver based on a leaky random cavity. Scientific Reports, 6(1). doi:10.1038/srep36096 es_ES
dc.description.references Smith, D. R., Gowda, V. R., Yurduseven, O., Larouche, S., Lipworth, G., Urzhumov, Y., & Reynolds, M. S. (2017). An analysis of beamed wireless power transfer in the Fresnel zone using a dynamic, metasurface aperture. Journal of Applied Physics, 121(1), 014901. doi:10.1063/1.4973345 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)