dc.description.abstract | [EN] We analyze in this paper a Waste Water Pre-Treatment Plant (WWTP) located at the Mediterranean coast with air radon concentration above Spanish action level (600 Bq per cubic meter). This paper presents a method for radon equilibrium determination by gamma spectrometry measuring of the radon progeny concentrations in the air, in order to estimate WWTP workers effective dose more exactly. The method is based on simultaneous sampling of air through a filter paper and alpha spectrometry measurement of radon activity concentration in the air. According to the measured radon activity concentration in the air of 368 +/- 45 Bq/m(3) the equilibrium factor between radon and progenies is estimated to be F=0.27, which is in good agreement with expected values. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Radiation Physics and Chemistry | es_ES |
dc.rights | Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) | es_ES |
dc.subject | Radon | es_ES |
dc.subject | Equilibrium factor | es_ES |
dc.subject | Gamma spectroscopy | es_ES |
dc.subject | Bateman equation | es_ES |
dc.subject | Radon progeny | es_ES |
dc.subject.classification | INGENIERIA NUCLEAR | es_ES |
dc.subject.classification | MECANICA DE FLUIDOS | es_ES |
dc.title | Air radon equilibrium factor measurement in a Waste Water Pre-Treatment Plant | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.radphyschem.2017.03.011 | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear | es_ES |
dc.description.bibliographicCitation | Martinez-Ferri, JE.; Juste Vidal, BJ.; Ortiz Moragón, J.; Martorell Alsina, SS.; Verdú Martín, GJ. (2017). Air radon equilibrium factor measurement in a Waste Water Pre-Treatment Plant. Radiation Physics and Chemistry. 140:20-24. doi:10.1016/j.radphyschem.2017.03.011 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://doi.org/10.1016/j.radphyschem.2017.03.011 | es_ES |
dc.description.upvformatpinicio | 20 | es_ES |
dc.description.upvformatpfin | 24 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 140 | es_ES |
dc.relation.pasarela | S\350633 | es_ES |