dc.description.abstract |
[ES] Este trabajo consiste en el desarrollo de un método no intrusivo para la cuantificación de yodo
en tiroides. El método consiste en la simulación mediante el programa MCNP, basado en el
método Monte Carlo, de la fluorescencia por rayos X producida al hacer incidir en la zona del
tiroides un haz de rayos X. Esta simulación tiene como objetivo optimizar diversos aspectos del
proceso de forma que se pueda minimizar al máximo posible la dosis recibida por el paciente,
especialmente en los órganos más sensibles a la radiación. Para ello, es necesario simular un
cuerpo humano, de la forma más adecuada posible a la realidad, con los órganos que se vean
más afectados por este método de medida. Se simula también el haz de rayos X y el detector.
Se utilizará un detector de semiconductor del tipo CdTe (teluro de cadmio). A partir de las
cuentas medidas en el detector y el espectro formado se llevará a cabo la cuantificación de yodo
en tiroides. El modelo desarrollado para MCNP pretende la realización de simulaciones
optimizando las distintas variables de distancia, posición, tiempo… para que se pueda
cuantificar yodo en tiroides en tiempo real afectando lo mínimo posible al paciente. |
es_ES |
dc.description.abstract |
[CA] Aquest treball consisteix en el desenvolupament d'un mètode no intrusiu per a la quantificació
de iode en tiroide. El mètode consisteix en la simulació mitjançant el programa MCNP, basat en
el mètode Montecarlo, de la fluorescència per raigs X produïda en fer incidir a la zona del tiroide
un feix de raigs X. Aquesta simulació té com a objectiu optimitzar diversos aspectes del procés
de manera que es pugui minimitzar al màxim possible la dosi rebuda pel pacient, especialment
en els òrgans més sensibles a la radiació. Per a això, és necessari simular un cos humà, de la
forma més adequada possible a la realitat, amb els òrgans que es vegin més afectats per aquest
mètode de mesura. Es simula també el feix de raigs X i el detector. S'utilitzarà un detector de
semiconductor de tipus CdTe (tel·luri de cadmi). A partir dels comptes mesures en el detector i
l'espectre format es durà a terme la quantificació de iode en tiroide. El model desenvolupat per
MCNP pretén la realització de simulacions optimitzant les diferents variables de distància,
posició, temps ... perquè es pugui quantificar iode en tiroide en temps real afectant el mínim
possible al pacient. |
es_ES |
dc.description.abstract |
[EN] This work consists in the development of a non-intrusive method for the quantification of iodine
in the thyroid. The method consists of the simulation using the MCNP code, based on the Monte
Carlo method, of the X-ray fluorescence produced when an X-ray beam impacts on the thyroid.
This simulation aims to optimize various aspects of process, so that the dose received by the
patient can be minimized as much as possible, especially in the organs most sensitive to
radiation. For this, it is necessary to simulate a human body, in the most approximate way
possible to reality, with the organs that are most affected by this method of measurement. The
X-ray beam and the detector are also simulated. A semiconductor detector of the CdTe type
(cadmium telluride) will be used. From the counts measured in the detector and the spectrum
formed, the quantification of iodine in the thyroid will be carried out. The model developed for
MCNP aims to carry out simulations by optimizing the different variables of distance, position,
time... so that in thyroid can be quantified in real time, affecting the patient as little as possible. |
es_ES |
dc.language |
Español |
es_ES |
dc.publisher |
Universitat Politècnica de València |
es_ES |
dc.rights |
Reserva de todos los derechos |
es_ES |
dc.subject |
Yodo |
es_ES |
dc.subject |
Tiroides |
es_ES |
dc.subject |
Dosis |
es_ES |
dc.subject |
Rayos X |
es_ES |
dc.subject |
Monte Carlo |
es_ES |
dc.subject |
Fluorescencia |
es_ES |
dc.subject |
Iode |
es_ES |
dc.subject |
tiroide |
es_ES |
dc.subject |
dosi |
es_ES |
dc.subject |
Raigs X |
es_ES |
dc.subject |
Montecarlo |
es_ES |
dc.subject |
Fluorescència |
es_ES |
dc.subject |
Iodine |
es_ES |
dc.subject |
Thyroid |
es_ES |
dc.subject |
Dose |
es_ES |
dc.subject |
X-Rays |
es_ES |
dc.subject |
Fluorescence |
es_ES |
dc.subject.classification |
INGENIERIA NUCLEAR |
es_ES |
dc.subject.other |
Grado en Ingeniería de la Energía-Grau en Enginyeria de l'Energia |
es_ES |
dc.title |
Desarrollo de un prototipo de analizador por RX de fluorescencia para la cuantificación de yodo en tiroides |
es_ES |
dc.type |
Proyecto/Trabajo fin de carrera/grado |
es_ES |
dc.rights.accessRights |
Cerrado |
es_ES |
dc.contributor.affiliation |
Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear |
es_ES |
dc.contributor.affiliation |
Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials |
es_ES |
dc.description.bibliographicCitation |
Ortiz Cortés, A. (2018). Desarrollo de un prototipo de analizador por RX de fluorescencia para la cuantificación de yodo en tiroides. http://hdl.handle.net/10251/106897 |
es_ES |
dc.description.accrualMethod |
TFGM |
es_ES |
dc.relation.pasarela |
TFGM\90531 |
es_ES |