Diseño y alternativas en la instalación de inyectores Venturi en riego localizado

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Diseño y alternativas en la instalación de inyectores Venturi en riego localizado

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Manzano Juarez, Juan es_ES
dc.contributor.author Palau, C.V. es_ES
dc.contributor.author Moreira de Azevedo, Benito es_ES
dc.contributor.author do Bomfim, G.V. es_ES
dc.contributor.author VASCONCELOS, DENISE V. es_ES
dc.date.accessioned 2018-10-13T04:30:51Z
dc.date.available 2018-10-13T04:30:51Z
dc.date.issued 2015 es_ES
dc.identifier.issn 0045-6888 es_ES
dc.identifier.uri http://hdl.handle.net/10251/110308
dc.description.abstract [ES] En la Universitat Politècnica de València, Valencia, España (39°29¿ N; 0°23¿ W; 20 m), ha sido estudiado el funcionamiento de cuatro prototipos de inyector Venturi y tres formas de instalación distintas. El funcionamiento se ha analizado bajo diversos parámetros, como pérdidas de carga, relación de caudales y rendimiento. Las formas de instalación analizadas han sido: sin inyección y con inyección y presiones negativas o positivas en la garganta. Las presiones se establecieron entre 10 y 40 m.c.a. A partir de los datos experimentales han sido procesados utilizando técnicas de regresión múltiple y análisis de la varianza. Con ellas, fue posible, a través de la integración de geometrías en función de los diámetros, caudales y presiones, obtener expresiones para prever la pérdida de carga o el caudal inyectado. Se pone de manifiesto que la relación de caudales y el rendimiento son mayores cuanto mayor es el diámetro de la aspiración y empeoran al reducirse el diámetro de la garganta, siendo estas las dimensiones que más condicionan la inyección. También, puede afirmarse que la pérdida de carga, para un mismo caudal inyectado, es inferior si la operación se realiza con presiones positivas que con presiones negativas. La relación de caudales o el rendimiento también proporcionan valores más elevados bajo esta forma de instalación propuesta. es_ES
dc.description.abstract [EN] The performance and installation alternatives of four Venturi injector prototypes were studied at Universitat Politècnica de València, Valencia, Spain (39°29¿ N; 0°23¿ W; 20 m). This device performance was studied under several parameters such as head loss, relation of flows and injection efficiency. The installation configurations analyzed were: without the injection of nutrients solution and with the injection either having negative or positive pressure at the Venturi throat. The inlet pressures were established between 10 and 40 m.w.c. The experimental data has been processed using multiple stepwise regression techniques and analysis of variance (ANOVA). Moreover, geometry integration versus diameters, flows and pressures is used to obtain some equations for predicting the head loss and injected flow. The results of the present study showed that the relation between flows and injection efficiency were better when the diameter of inlet nutrient line increases and become worse when decreases the diameter of the Venturi throat. Accordingly, these dimensions become very important in the design prototype and installation configuration. Furthermore, after the analysis of laboratory experiments it can be concluded that head losses, at the same injected flow, were lower if the injection was carried out with positive pressures at the throat than in the case of negative pressures. Also in this case, the relationship between flow rates and injection efficiency leaded to a good performance of the proposed installation. es_ES
dc.language Español es_ES
dc.relation.ispartof Revista Ciencia Agronomica es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Pressurized irrigation es_ES
dc.subject Chemigation es_ES
dc.subject Fertigation es_ES
dc.subject.classification INGENIERIA HIDRAULICA es_ES
dc.subject.classification INGENIERIA AGROFORESTAL es_ES
dc.title Diseño y alternativas en la instalación de inyectores Venturi en riego localizado es_ES
dc.title.alternative Design and installation alternatives of Venturi injectors in drip irrigation es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.5935/1806-6690.20150008 es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Rural y Agroalimentaria - Departament d'Enginyeria Rural i Agroalimentària es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient es_ES
dc.description.bibliographicCitation Manzano Juarez, J.; Palau, C.; Moreira De Azevedo, B.; Do Bomfim, G.; Vasconcelos, DV. (2015). Diseño y alternativas en la instalación de inyectores Venturi en riego localizado. Revista Ciencia Agronomica. 46(2):287-298. doi:10.5935/1806-6690.20150008 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/10.5935/1806-6690.20150008 es_ES
dc.description.upvformatpinicio 287 es_ES
dc.description.upvformatpfin 298 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 46 es_ES
dc.description.issue 2 es_ES
dc.relation.pasarela S\298643 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem