Mostrar el registro sencillo del ítem
dc.contributor.author | Prats-Boluda, Gema | es_ES |
dc.contributor.author | Ye Lin, Yiyao | es_ES |
dc.contributor.author | Bueno Barrachina, José Manuel | es_ES |
dc.contributor.author | Senent, Esther | es_ES |
dc.contributor.author | Rodríguez de Sanabria Gil, Rafael | es_ES |
dc.contributor.author | Garcia-Casado, Javier | es_ES |
dc.date.accessioned | 2018-12-29T21:01:14Z | |
dc.date.available | 2018-12-29T21:01:14Z | |
dc.date.issued | 2015 | es_ES |
dc.identifier.issn | 0957-0233 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/114604 | |
dc.description.abstract | [EN] Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization). | es_ES |
dc.description.sponsorship | Research supported in part by: a grant from the Conselleria d'Educacio, Cultura i Esport, Generalitat Valenciana Conselleria (GV/2014/029), a grant from the Universitat Politecnica de Valencia (SP20120490) and by a VLC_Campus grant (Prematuro ID34). | |
dc.language | Inglés | es_ES |
dc.publisher | IOP Publishing | es_ES |
dc.relation.ispartof | Measurement Science and Technology | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Flexible electrode | es_ES |
dc.subject | Wireless sensor | es_ES |
dc.subject | Signal conditioning | es_ES |
dc.subject | Ring electrode | es_ES |
dc.subject.classification | TECNOLOGIA ELECTRONICA | es_ES |
dc.subject.classification | INGENIERIA ELECTRICA | es_ES |
dc.subject.classification | ORGANIZACION DE EMPRESAS | es_ES |
dc.title | Development of a portable wireless system for bipolar concentric ECG recording | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1088/0957-0233/26/7/075102 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//GV%2F2014%2F029/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/UPV//SP20120490/ | es_ES |
dc.rights.accessRights | Cerrado | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Organización de Empresas - Departament d'Organització d'Empreses | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Eléctrica - Departament d'Enginyeria Elèctrica | es_ES |
dc.description.bibliographicCitation | Prats-Boluda, G.; Ye Lin, Y.; Bueno Barrachina, JM.; Senent, E.; Rodríguez De Sanabria Gil, R.; Garcia-Casado, J. (2015). Development of a portable wireless system for bipolar concentric ECG recording. Measurement Science and Technology. 26(7):1-10. https://doi.org/10.1088/0957-0233/26/7/075102 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://doi.org/10.1088/0957-0233/26/7/075102 | es_ES |
dc.description.upvformatpinicio | 1 | es_ES |
dc.description.upvformatpfin | 10 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 26 | es_ES |
dc.description.issue | 7 | es_ES |
dc.relation.pasarela | S\292016 | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | Universitat Politècnica de València | es_ES |