- -

Visual acuity with computer simulated and lens-induced astigmatism

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Visual acuity with computer simulated and lens-induced astigmatism

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Remón Martín, Laura es_ES
dc.contributor.author Benlloch, Josefa es_ES
dc.contributor.author Pons Marti, Amparo es_ES
dc.contributor.author Monsoriu Serra, Juan Antonio es_ES
dc.contributor.author Furlan, Walter D. es_ES
dc.date.accessioned 2019-01-10T21:03:46Z
dc.date.available 2019-01-10T21:03:46Z
dc.date.issued 2014 es_ES
dc.identifier.issn 0078-5466 es_ES
dc.identifier.uri http://hdl.handle.net/10251/115249
dc.description.abstract [EN] The relationship between spherical and astigmatic refractive errors and their associated visual acuity is investigated in this work by means of two different approaches. In the first one, different refractive errors were induced in normal subjects by trial lenses. In the second one, defocused images were simulated numerically by the optical transfer function of a model eye and then judged by the same subjects. The amount of defocus (measured in terms of the modulus of the dioptric power vector) necessary to reduce the visual acuity to 0.1 logMAR and to 0.4 logMAR was computed with each method and then compared. We found that the visual system is clearly more tolerant to lens-induced defocus than for the computer simulated one. However, no significant differences in visual acuity were found for astigmatism of the same power but different axes in each method. es_ES
dc.description.sponsorship We acknowledge financial support from Ministerio de Economia y Competitividad (Grant FIS2011-23175) and Generalitat Valenciana (PROMETEO II 2014-072), Spain. The authors would like to thank the anonymous reviewers for their valuable comments and suggestions to improve the quality of the paper.
dc.language Inglés es_ES
dc.relation info:eu-repo/grantAgreementGV//PROMETEOII/2014/072/ es_ES
dc.relation.ispartof OPTICA APPLICATA es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Visual acuity es_ES
dc.subject Simulated defocus es_ES
dc.subject Astigmatism es_ES
dc.subject Lens-induced defocus es_ES
dc.subject Power vector es_ES
dc.subject Zernike polynomials es_ES
dc.subject.classification FISICA APLICADA es_ES
dc.title Visual acuity with computer simulated and lens-induced astigmatism es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.5277/oa140403 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MICINN//FIS2011-23175/ES/DISEÑO Y REALIZACION DE ESTRUCTURAS DIFRACTIVAS APERIODICAS: NUEVAS LENTES OFTALMICAS Y OTRAS APLICACIONES/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2014%2F072/ES/Grupo de fibras ópticas y procesado de señal/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//FPA%2F2014%2F070/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada es_ES
dc.description.bibliographicCitation Remón Martín, L.; Benlloch, J.; Pons Marti, A.; Monsoriu Serra, JA.; Furlan, WD. (2014). Visual acuity with computer simulated and lens-induced astigmatism. OPTICA APPLICATA. 44(4):521-531. https://doi.org/10.5277/oa140403 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion http://doi.org/ 10.5277/oa140403 es_ES
dc.description.upvformatpinicio 521 es_ES
dc.description.upvformatpfin 531 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 44 es_ES
dc.description.issue 4 es_ES
dc.relation.pasarela S\280989 es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Ministerio de Economía, Industria y Competitividad es_ES
dc.contributor.funder Ministerio de Ciencia e Innovación


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem