Mostrar el registro sencillo del ítem
dc.contributor.author | Campins-Falcó, P. | es_ES |
dc.contributor.author | Tortajada-Genaro, Luis Antonio | es_ES |
dc.contributor.author | Meseguer-Lloret, S. | es_ES |
dc.contributor.author | Bosch-Reig, F. | es_ES |
dc.date.accessioned | 2019-01-27T21:01:51Z | |
dc.date.available | 2019-01-27T21:01:51Z | |
dc.date.issued | 2002 | es_ES |
dc.identifier.issn | 1618-2642 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/116179 | |
dc.description | The final publication is available at http://doi.org/ 10.1007/s00216-002-1637-8 | |
dc.description.abstract | [EN] The simultaneous determination of chromium and cobalt in water samples has been studied. Chemiluminescence registers based on the luminol-hydrogen peroxide reaction have obtained by a batch procedure. PLS algorithms have employed to model the time-response (formation and destruction of emitter). The influence of the presence of two metals and the non-linearity relationship between response and concentration have been evaluated in the signal. Different experimental designs and the selection of variables have been tested. The calibration set has been selected based on two criteria: unicomponent and/or bicomponent standard solutions and the slope calculated from linear univariate calibration. The response has been modelled providing high percentages of explained variance, robust models and low prediction errors. The proposed methodology has been validated using test standard solutions and a standard reference material of fresh water. Accurate results have proved the advantages of this method for the simultaneous determination of chromium and cobalt in water samples. | es_ES |
dc.description.sponsorship | The authors are grateful to the DGICYT (Project no PB 97–1387) for financial support. S.M.Ll. and L.A.T.G. express their gratitude to Ministerio de Educación y Cultura (Spain) for the predoctoral grant. | |
dc.language | Inglés | es_ES |
dc.publisher | Springer-Verlag | es_ES |
dc.relation.ispartof | Analytical and Bioanalytical Chemistry | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Chemiluminescence | es_ES |
dc.subject | Chromium and cobalt determination | es_ES |
dc.subject | Water | es_ES |
dc.subject | Luminol-hydrogen peroxide reaction | es_ES |
dc.subject | Simultaneous analysis | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | Multivariate calibration applied to simultaneous chemiluminiscence determination of Cobalt and Chromium | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1007/s00216-002-1637-8 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MECD//PB97-1387/ | |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.description.bibliographicCitation | Campins-Falcó, P.; Tortajada-Genaro, LA.; Meseguer-Lloret, S.; Bosch-Reig, F. (2002). Multivariate calibration applied to simultaneous chemiluminiscence determination of Cobalt and Chromium. Analytical and Bioanalytical Chemistry. 374(7-8):1223-1229. https://doi.org/10.1007/s00216-002-1637-8 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | http://doi.org/ 10.1007/s00216-002-1637-8 | es_ES |
dc.description.upvformatpinicio | 1223 | es_ES |
dc.description.upvformatpfin | 1229 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 374 | es_ES |
dc.description.issue | 7-8 | es_ES |
dc.identifier.pmid | 12474089 | |
dc.relation.pasarela | S\28511 | es_ES |
dc.contributor.funder | Ministerio de Educación y Cultura |