dc.description.abstract |
[ES] El objetivo de este experimento es el estudio del crecimiento del biofouling en intercambiadores de calor. Para ello se ha diseñado y construido una planta piloto en la cual cada uno de los tubos funciona como sistema independiente. En cada uno de los tubos se controlan parámetros como presión, temperatura y caudal, que definen indirectamente la capa de biofouling depositada en el interior del tubo. El seguimiento de estos parámetros permitirá establecer los valores de la resistencia a la transmisión de calor, resistencia friccional y velocidad del fluido. |
es_ES |
dc.language |
Español |
es_ES |
dc.publisher |
Universitat Politècnica de València |
|
dc.relation.ispartof |
Ingeniería del Agua |
|
dc.rights |
Reserva de todos los derechos |
es_ES |
dc.subject |
Ingeniería del agua |
es_ES |
dc.subject |
Ingeniería civil |
es_ES |
dc.subject |
Ingeniería hidráulica |
es_ES |
dc.title |
Crecimiento del biofouling en intercambiadores de calor-condensadores refrigerados con agua de mar |
es_ES |
dc.type |
Artículo |
es_ES |
dc.date.updated |
2019-03-27T12:12:33Z |
|
dc.identifier.doi |
10.4995/ia.1996.2708 |
|
dc.rights.accessRights |
Abierto |
es_ES |
dc.description.bibliographicCitation |
Eguía López, E.; Vidart, TF.; Bezanilla, JA.; Amieva Del Val, JJ.; Otero González, FM.; Río Calonge, B.; Girón Portilla, MA. (1996). Crecimiento del biofouling en intercambiadores de calor-condensadores refrigerados con agua de mar. Ingeniería del Agua. 3(4):45-56. https://doi.org/10.4995/ia.1996.2708 |
es_ES |
dc.description.accrualMethod |
SWORD |
es_ES |
dc.relation.publisherversion |
https://doi.org/10.4995/ia.1996.2708 |
es_ES |
dc.description.upvformatpinicio |
45 |
es_ES |
dc.description.upvformatpfin |
56 |
es_ES |
dc.type.version |
info:eu-repo/semantics/publishedVersion |
es_ES |
dc.description.volume |
3 |
|
dc.description.issue |
4 |
|
dc.identifier.eissn |
1886-4996 |
|
dc.description.references |
Characklis, W. G. y Marshall, K. C. (1990). Biofilms, Wiley Series in Ecological and Applied Microbiology. |
es_ES |
dc.description.references |
Chenoweth, J. M. (1990) Final Report of the HTRI/TEMA Joint Committee to Review the Fouling Section of the TEMA Standards, Heat Transfer Engineering. 1 1, N°1, 73-107. |
es_ES |
dc.description.references |
Chow, W. (1985). Condenser Biofouling Control: The State of Art, Electrical Research Power Institute. 1-11. |
es_ES |
dc.description.references |
Flemming, H. C. (1990) Biofouling in Water Treatment, Proceedings of the International Workshops on Industrial Biofouling and Biocorrosion, Stuttgart, 47-80. |
es_ES |
dc.description.references |
Knox-Holmes, B. (1993) Biofouling Control with Low Levels of Copper and Chlorine, Biofouling, 7, 157-166. |
es_ES |
dc.description.references |
LeBleu, J. B. (1990) Protective Coatings for Cooling Water Systems in Southern Coastal Power Plants, Journal of Protective Coatings & Linings, 20-25. |
es_ES |
dc.description.references |
Lewis, J. R. y Mercer, A. D. (1984) Corrosion and Marine Growth on Offshore Structure, Ellis Horwood Limeted. |
es_ES |
dc.description.references |
Nosetani, T.; Hotta, Y.; Sato, S.; Onda K.; Nakamura, T. y Kato, Y. (1989). In-Situ Evaluation of Enhanced Heat Transfer Tubes for Surface Condenser (SC Tubes), National Heat Transfer Conference Philadelphia, 31, N° 1, 54-64. |
es_ES |
dc.description.references |
Sengupta, S.; Lira, R.; Poteat, L; Mussaili, Y. & Chow, W. (1987) Experimental Test Facility For Evaluating Marine Biofouling in Condensers: Test with Targeted Chlorination, American Society of Mechanical Engineers, Heat Transfer Division, 86, 15-22. |
es_ES |
dc.description.references |
Somerscales, E. F. C. y Kassemit, M. (1987) Fouling Due to Corrosion Products Formed on a Heat Transfers Surface, Journal of Heat Transfer, 109, 267-271. |
es_ES |
dc.description.references |
Tatnall, R. E. (1990) Case Histories: Biocorrosion, Proceedings of the International Workshops on Industrial Biofouling and Biocorrosion, Stuttgart, 165-185. |
es_ES |
dc.description.references |
Tijhuis, L. (1989) The Biofilm Airlift Suspension Reactor, Department of Biochemical Engineering, Delft University of Technology, The Netherlands. |
es_ES |