How Reliable Are Standard Thermal Response Tests? An Assessment Based on Long-TermThermal Response Tests Under Different Operational Conditions

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

  • Estadisticas de Uso

How Reliable Are Standard Thermal Response Tests? An Assessment Based on Long-TermThermal Response Tests Under Different Operational Conditions

Show full item record

Urchueguía Schölzel, JF.; Lemus Zúñiga, LG.; Oliver Villanueva, JV.; Badenes Badenes, B.; Mateo Pla, MÁ.; Cuevas-Castell, JM. (2018). How Reliable Are Standard Thermal Response Tests? An Assessment Based on Long-TermThermal Response Tests Under Different Operational Conditions. Energies. 11(12). https://doi.org/10.3390/en11123347

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/121359

Files in this item

Item Metadata

Title: How Reliable Are Standard Thermal Response Tests? An Assessment Based on Long-TermThermal Response Tests Under Different Operational Conditions
Author: Urchueguía Schölzel, Javier Fermín Lemus Zúñiga, Lenin Guillermo Oliver Villanueva, José Vicente Badenes Badenes, Borja Mateo Pla, Miguel Ángel Cuevas-Castell, José Manuel
UPV Unit: Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada
Universitat Politècnica de València. Departamento de Informática de Sistemas y Computadores - Departament d'Informàtica de Sistemes i Computadors
Universitat Politècnica de València. Departamento de Ingeniería Rural y Agroalimentaria - Departament d'Enginyeria Rural i Agroalimentària
Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient
Issued date:
Abstract:
[EN] In this contribution, we analyze the results of a number of thermal response test (TRT) experiments performed during several years at the same location at our university campus in Valencia (Spain), a permeable saturated ...[+]
Subjects: Shallow geothermal energy , Borehole heat exchangers , Thermal response test , Ground source heat pumps , Finite line-source method , Moving infinite line-source theory , Moving finite line-source theory
Copyrigths: Reconocimiento (by)
Source:
Energies. (eissn: 1996-1073 )
DOI: 10.3390/en11123347
Publisher:
MDPI AG
Publisher version: https://doi.org/10.3390/en11123347
Project ID:
info:eu-repo/grantAgreement/EC/H2020/657982/EU/CHEAP AND EFFICIENT APPLICATION OF RELIABLE GROUND SOURCE HEAT EXCHANGERS AND PUMPS/
info:eu-repo/grantAgreement/EC/H2020/727583/EU/Advanced materials and processes to improve performance and cost-efficiency of Shallow Geothermal systems and Underground Thermal Storage/
Thanks:
This research was funded by the European Union's Horizon 2020 Research and Innovation program under grant agreement No [657982] and [727583].