Mostrar el registro sencillo del ítem
dc.contributor.author | Pardo, Fernando | es_ES |
dc.contributor.author | De Santiago, Cristina | es_ES |
dc.contributor.author | De Groot-Viana, Maria | es_ES |
dc.contributor.author | Urchueguía Schölzel, Javier Fermín | es_ES |
dc.contributor.author | Arcos, José Luis | es_ES |
dc.contributor.author | Badenes Badenes, Borja | es_ES |
dc.date.accessioned | 2019-06-28T20:04:54Z | |
dc.date.available | 2019-06-28T20:04:54Z | |
dc.date.issued | 2018 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/122888 | |
dc.description.abstract | [EN] The paper describes the thermo-mechanical behaviour of an experimental pre-cast driven pile, properly instrumented and prepared to operate as a heat exchanger foundation element under the simultaneous action of mechanical and thermal loads. Firstly, in situ static vertical load tests were carried out to analyse the pile mechanical behaviour. Afterwards, two thermal tests were performed under constant mechanical load. The first thermal test was carried out to characterise the pile¿ground system. By means of the second thermal test, the conditions of the pile in a geothermal installation of an office building operating in cooling mode were simulated. The influence of the thermal loads on the structural and geotechnical performance of the pile was subsequently analysed. Heating the pile leads to increases in axial and end-bearing loads, changes in shear stresses distribution and reduction of factors of safety for compressive ground resistance and for structural resistance of the pile. | es_ES |
dc.description.sponsorship | The authors thank the Spanish Ministry of Economy and Competitiveness for its financial support, through the programme INNPACTO 2011, for the design, installation and instrumentation of the geothermal pile in Valencia. | |
dc.language | Inglés | es_ES |
dc.publisher | ICE Publishing | es_ES |
dc.relation.ispartof | Environmental Geotechnics | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Buildings | es_ES |
dc.subject | Structures design | es_ES |
dc.subject | Energy piles | es_ES |
dc.subject | Piling | es_ES |
dc.subject.classification | FISICA APLICADA | es_ES |
dc.subject.classification | MECANICA DE FLUIDOS | es_ES |
dc.title | Effect of thermal loads on pre-cast concrete thermopile in Valencia, Spain | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1680/jenge.17.00103 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//IPT-2011-1214-380000/ES/Caracterización termo-mecánica y nuevas técnicas de diseño de pilotes termoactivos/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto Universitario de Matemática Pura y Aplicada - Institut Universitari de Matemàtica Pura i Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Física Aplicada - Departament de Física Aplicada | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient | es_ES |
dc.description.bibliographicCitation | Pardo, F.; De Santiago, C.; De Groot-Viana, M.; Urchueguía Schölzel, JF.; Arcos, JL.; Badenes Badenes, B. (2018). Effect of thermal loads on pre-cast concrete thermopile in Valencia, Spain. Environmental Geotechnics. https://doi.org/10.1680/jenge.17.00103 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1680/jenge.17.00103 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.identifier.eissn | 2051-803X | es_ES |
dc.relation.pasarela | S\373028 | es_ES |
dc.contributor.funder | Ministerio de Ciencia e Innovación | es_ES |