Optimization of thermal design and geometrical parameters of a flat tube-fin adsorbent bed for automobile air-conditioning

RiuNet: Institutional repository of the Polithecnic University of Valencia

Share/Send to

Cited by

Statistics

Optimization of thermal design and geometrical parameters of a flat tube-fin adsorbent bed for automobile air-conditioning

Show full item record

Verde Trindade, M.; Harby Mohamed Abd Alaal, K.; Corberán, JM. (2017). Optimization of thermal design and geometrical parameters of a flat tube-fin adsorbent bed for automobile air-conditioning. Applied Thermal Engineering. 111:489-502. https://doi.org/10.1016/j.applthermaleng.2016.09.099

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10251/123462

Files in this item

Item Metadata

Title: Optimization of thermal design and geometrical parameters of a flat tube-fin adsorbent bed for automobile air-conditioning
Author:
UPV Unit: Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada
Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica
Issued date:
Abstract:
Adsorbent bed design and performance strongly affect the overall performance of adsorption systems. In the present study, an analytical model was developed to determine the optimum geometrical and thermal parameters of a ...[+]
Subjects: Adsorption chiller , Flat tube-fin heat exchanger , Optimization , Waste heat recovery , Automotive A/C system , Extended surface
Copyrigths: Reconocimiento - No comercial - Sin obra derivada (by-nc-nd)
Source:
Applied Thermal Engineering. (issn: 1359-4311 )
DOI: 10.1016/j.applthermaleng.2016.09.099
Publisher:
Elsevier
Publisher version: http://doi.org/10.1016/j.applthermaleng.2016.09.099
Thanks:
This work has been partially supported by the Thermally Operated Mobile Air Conditioning Systems (TOPMACS).
Type: Artículo