Freeman, R. D. (1972). Oxygen consumption by the component layers of the cornea. The Journal of Physiology, 225(1), 15-32. doi:10.1113/jphysiol.1972.sp009927
CHALMERS, R. L., McNALLY, J. J., SCHEIN, O. D., KATZ, J., TIELSCH, J. M., ALFONSO, E., … SHOVLIN, J. (2007). Risk Factors for Corneal Infiltrates with Continuous Wear of Contact Lenses. Optometry and Vision Science, 84(7), 573-579. doi:10.1097/opx.0b013e3180dc9a12
Schein, O. D., McNally, J. J., Katz, J., Chalmers, R. L., Tielsch, J. M., Alfonso, E., … Shovlin, J. (2005). The Incidence of Microbial Keratitis among Wearers of a 30-Day Silicone Hydrogel Extended-Wear Contact Lens. Ophthalmology, 112(12), 2172-2179. doi:10.1016/j.ophtha.2005.09.014
[+]
Freeman, R. D. (1972). Oxygen consumption by the component layers of the cornea. The Journal of Physiology, 225(1), 15-32. doi:10.1113/jphysiol.1972.sp009927
CHALMERS, R. L., McNALLY, J. J., SCHEIN, O. D., KATZ, J., TIELSCH, J. M., ALFONSO, E., … SHOVLIN, J. (2007). Risk Factors for Corneal Infiltrates with Continuous Wear of Contact Lenses. Optometry and Vision Science, 84(7), 573-579. doi:10.1097/opx.0b013e3180dc9a12
Schein, O. D., McNally, J. J., Katz, J., Chalmers, R. L., Tielsch, J. M., Alfonso, E., … Shovlin, J. (2005). The Incidence of Microbial Keratitis among Wearers of a 30-Day Silicone Hydrogel Extended-Wear Contact Lens. Ophthalmology, 112(12), 2172-2179. doi:10.1016/j.ophtha.2005.09.014
Sweeney, D. F. (2003). Clinical Signs of Hypoxia with High-Dk Soft Lens Extended Wear: Is the Cornea Convinced? Eye & Contact Lens: Science & Clinical Practice, S22-S25. doi:10.1097/00140068-200301001-00007
HARVITT, D. M., & BONANNO, J. A. (1999). Re-Evaluation of the Oxygen Diffusion Model for Predicting Minimum Contact Lens Dk/t Values Needed to Avoid Corneal Anoxia. Optometry and Vision Science, 76(10), 712-719. doi:10.1097/00006324-199910000-00023
Polse, K. A., & Mandell, R. B. (1970). Critical Oxygen Tension at the Corneal Surface. Archives of Ophthalmology, 84(4), 505-508. doi:10.1001/archopht.1970.00990040507021
Giasson, C., & Bonanno, J. A. (1995). Acidification of rabbit corneal endothelium during contact lens wearin vitro. Current Eye Research, 14(4), 311-318. doi:10.3109/02713689509033531
Riley, M. V. (1969). Glucose and oxygen utilization by the rabbit cornea. Experimental Eye Research, 8(2), 193-200. doi:10.1016/s0014-4835(69)80031-x
Frahm, B., Lane, P., M�rkl, H., & P�rtner, R. (2003). Improvement of a mammalian cell culture process by adaptive, model-based dialysis fed-batch cultivation and suppression of apoptosis. Bioprocess and Biosystems Engineering, 26(1), 1-10. doi:10.1007/s00449-003-0335-z
Compañ, V., Aguilella-Arzo, M., Del Castillo, L. F., Hernández, S. I., & Gonzalez-Meijome, J. M. (2016). Analysis of the application of the generalized monod kinetics model to describe the human corneal oxygen-consumption rate during soft contact lens wear. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(8), 2269-2281. doi:10.1002/jbm.b.33764
Bonanno, J. A., Clark, C., Pruitt, J., & Alvord, L. (2009). Tear Oxygen Under Hydrogel and Silicone Hydrogel Contact Lenses in Humans. Optometry and Vision Science, 86(8), E936-E942. doi:10.1097/opx.0b013e3181b2f582
Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2008). Diffusion and Monod kinetics to determine in vivo human corneal oxygen-consumption rate during soft contact-lens wear. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 90B(1), 202-209. doi:10.1002/jbm.b.31274
Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2009). Modeling Corneal Metabolism and Oxygen Transport During Contact Lens Wear. Optometry and Vision Science, 86(5), 454-466. doi:10.1097/opx.0b013e31819f9e70
Larrea, X., & Bu¨chler, P. (2009). A Transient Diffusion Model of the Cornea for the Assessment of Oxygen Diffusivity and Consumption. Investigative Opthalmology & Visual Science, 50(3), 1076. doi:10.1167/iovs.08-2479
Alvord, L. A., Hall, W. J., Keyes, L. D., Morgan, C. F., & Winterton, L. C. (2007). Corneal Oxygen Distribution With Contact Lens Wear. Cornea, 26(6), 654-664. doi:10.1097/ico.0b013e31804f5a22
Del Castillo, L. F., da Silva, A. R. F., Hernández, S. I., Aguilella, M., Andrio, A., Mollá, S., & Compañ, V. (2015). Diffusion and Monod kinetics model to determine in vivo human corneal oxygen-consumption rate during soft contact lens wear. Journal of Optometry, 8(1), 12-18. doi:10.1016/j.optom.2014.06.002
Chandel, N. S., Budinger, G. R. S., Choe, S. H., & Schumacker, P. T. (1997). Cellular Respiration during Hypoxia. Journal of Biological Chemistry, 272(30), 18808-18816. doi:10.1074/jbc.272.30.18808
Leung, B. K., Bonanno, J. A., & Radke, C. J. (2011). Oxygen-deficient metabolism and corneal edema. Progress in Retinal and Eye Research, 30(6), 471-492. doi:10.1016/j.preteyeres.2011.07.001
Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2008). Polarographic Method for Measuring Oxygen Diffusivity and Solubility in Water-Saturated Polymer Films: Application to Hypertransmissible Soft Contact Lenses. Industrial & Engineering Chemistry Research, 47(10), 3540-3550. doi:10.1021/ie071071a
Compañ, V., Andrio, A., López-Alemany, A., Riande, E., & Refojo, M. F. (2002). Oxygen permeability of hydrogel contact lenses with organosilicon moieties. Biomaterials, 23(13), 2767-2772. doi:10.1016/s0142-9612(02)00012-1
Gonzalez-Meijome, J. M., Compañ-Moreno, V., & Riande, E. (2008). Determination of Oxygen Permeability in Soft Contact Lenses Using a Polarographic Method: Estimation of Relevant Physiological Parameters. Industrial & Engineering Chemistry Research, 47(10), 3619-3629. doi:10.1021/ie071403b
Compa�, V., L�pez, M. L., Andrio, A., L�pez-Alemany, A., & Refojo, M. F. (1999). Determination of the oxygen transmissibility and permeability of hydrogel contact lenses. Journal of Applied Polymer Science, 72(3), 321-327. doi:10.1002/(sici)1097-4628(19990418)72:3<321::aid-app2>3.0.co;2-l
Gavara, R., & Compañ, V. (2016). Oxygen, water, and sodium chloride transport in soft contact lenses materials. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(8), 2218-2231. doi:10.1002/jbm.b.33762
Compañ, V., Tiemblo, P., García, F., García, J. M., Guzmán, J., & Riande, E. (2005). A potentiostatic study of oxygen transport through poly(2-ethoxyethyl methacrylate-co-2,3-dihydroxypropylmethacrylate) hydrogel membranes. Biomaterials, 26(18), 3783-3791. doi:10.1016/j.biomaterials.2004.09.061
Wang, J., Fonn, D., Simpson, T. L., & Jones, L. (2003). Precorneal and Pre- and Postlens Tear Film Thickness Measured Indirectly with Optical Coherence Tomography. Investigative Opthalmology & Visual Science, 44(6), 2524. doi:10.1167/iovs.02-0731
Nichols, J. J., & King-Smith, P. E. (2003). Thickness of the Pre- and Post–Contact Lens Tear Film Measured In Vivo by Interferometry. Investigative Opthalmology & Visual Science, 44(1), 68. doi:10.1167/iovs.02-0377
Compañ, V., Aguilella-Arzo, M., Edrington, T. B., & Weissman, B. A. (2016). Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear. Optometry and Vision Science, 93(11), 1339-1348. doi:10.1097/opx.0000000000000988
Compañ, V., Aguilella-Arzo, M., & Weissman, B. A. (2017). Corneal Equilibrium Flux as a Function of Corneal Surface Oxygen Tension. Optometry and Vision Science, 94(6), 672-679. doi:10.1097/opx.0000000000001083
Papas, E. B., & Sweeney, D. F. (2016). Interpreting the corneal response to oxygen: Is there a basis for re-evaluating data from gas-goggle studies? Experimental Eye Research, 151, 222-226. doi:10.1016/j.exer.2016.08.019
Alentiev, A. Y., Shantarovich, V. P., Merkel, T. C., Bondar, V. I., Freeman, B. D., & Yampolskii, Y. P. (2002). Gas and Vapor Sorption, Permeation, and Diffusion in Glassy Amorphous Teflon AF1600. Macromolecules, 35(25), 9513-9522. doi:10.1021/ma020494f
Lin, H., & Freeman, B. D. (2005). Gas and Vapor Solubility in Cross-Linked Poly(ethylene Glycol Diacrylate). Macromolecules, 38(20), 8394-8407. doi:10.1021/ma051218e
Koros, W. J., Paul, D. R., & Rocha, A. A. (1976). Carbon dioxide sorption and transport in polycarbonate. Journal of Polymer Science: Polymer Physics Edition, 14(4), 687-702. doi:10.1002/pol.1976.180140410
Nicolson, P. C., & Vogt, J. (2001). Soft contact lens polymers: an evolution. Biomaterials, 22(24), 3273-3283. doi:10.1016/s0142-9612(01)00165-x
Cheng, X., & Pinsky, P. M. (2017). A numerical model for metabolism, metabolite transport and edema in the human cornea. Computer Methods in Applied Mechanics and Engineering, 314, 323-344. doi:10.1016/j.cma.2016.09.014
Li, L., & Tighe, B. (2005). Numerical simulation of corneal transport processes. Journal of The Royal Society Interface, 3(7), 303-310. doi:10.1098/rsif.2005.0085
[-]