Measurement and numerical simulation of single-sided mechanical ventilation in broiler houses

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Measurement and numerical simulation of single-sided mechanical ventilation in broiler houses

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Bustamante García, E. es_ES
dc.contributor.author Calvet, S. es_ES
dc.contributor.author Estellés, F. es_ES
dc.contributor.author Torres, A.G. es_ES
dc.contributor.author Hospitaler Pérez, Antonio es_ES
dc.date.accessioned 2020-04-06T08:55:40Z
dc.date.available 2020-04-06T08:55:40Z
dc.date.issued 2017 es_ES
dc.identifier.issn 1537-5110 es_ES
dc.identifier.uri http://hdl.handle.net/10251/140185
dc.description.abstract [EN] In recent years, some broiler production farms especially in Mediterranean areas, have incorporated single-sided mechanical ventilation (i.e. air inlets and fans are located in the same lateral wall). However, little scientific information on the performance of mechanical single-sided ventilation systems is available to date. This ventilation method is fitted to broiler houses because this ventilation system appears appropriate to diminish the stress and mortality of broilers during hot seasons in this climate. To analyse the single-sided ventilation method scientifically, the indoor environments of broiler houses were examined by numerical simulation using computational fluid dynamics (CFD) with validation using a range of different buildings with direct measurements using a multi-sensor system. An analysis of variation of the results of the validation tests produced to a p-value of 0.3908. Thus, the methodology employed (i.e. CFD or sensors) was not significant. The CFD simulations showed a wide range of values for air velocity: the minimum value of air velocity at broiler level was 0.52 +/- 0.40 m s(-1) and the maximum was 1.29 +/- 0.41 m s(-1). Two major conclusions were drawn in terms indoor air velocity: (i) excessive heterogeneity in the plane where the animals were located; and (ii) insufficient air movement to contribute to the thermoregulation of the birds and lower their internal heat and associated thermal stress in occasional periods of hot weather. es_ES
dc.description.sponsorship This work was funded by the project GV04B-511 (Generalitat Valenciana, Spain) and by the Vicerrectorado of Investigacion of the Universitat Politecnica de Valencia (Programa de Apoyo a la Investigacion y Desarrollo Multidisciplinar Project PAID register 2614). es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Biosystems Engineering es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Broiler farm es_ES
dc.subject Computational Fluid Dynamics (CFD) es_ES
dc.subject Livestock buildings es_ES
dc.subject Mechanical ventilation es_ES
dc.subject Sensors es_ES
dc.subject Single-sided es_ES
dc.subject.classification INGENIERIA DE LA CONSTRUCCION es_ES
dc.subject.classification PRODUCCION ANIMAL es_ES
dc.subject.classification ESTADISTICA E INVESTIGACION OPERATIVA es_ES
dc.title Measurement and numerical simulation of single-sided mechanical ventilation in broiler houses es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.biosystemseng.2017.05.009 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//GV04B%2F511/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV//PAID-2614 es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ciencia Animal - Departament de Ciència Animal es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Estadística e Investigación Operativa Aplicadas y Calidad - Departament d'Estadística i Investigació Operativa Aplicades i Qualitat es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de la Construcción y de Proyectos de Ingeniería Civil - Departament d'Enginyeria de la Construcció i de Projectes d'Enginyeria Civil es_ES
dc.description.bibliographicCitation Bustamante García, E.; Calvet, S.; Estellés, F.; Torres, A.; Hospitaler Pérez, A. (2017). Measurement and numerical simulation of single-sided mechanical ventilation in broiler houses. Biosystems Engineering. 160:55-68. https://doi.org/10.1016/j.biosystemseng.2017.05.009 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.biosystemseng.2017.05.009 es_ES
dc.description.upvformatpinicio 55 es_ES
dc.description.upvformatpfin 68 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 160 es_ES
dc.relation.pasarela S\341200 es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Universitat Politècnica de València es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem