Mostrar el registro sencillo del ítem
dc.contributor.author | do Nascimento, Noelle M. | es_ES |
dc.contributor.author | Juste-Dolz, Augusto | es_ES |
dc.contributor.author | Grau-García, Elena | es_ES |
dc.contributor.author | Roman-Ivorra, Jose A. | es_ES |
dc.contributor.author | Puchades, Rosa | es_ES |
dc.contributor.author | Maquieira Catala, Angel | es_ES |
dc.contributor.author | Morais, Sergi | es_ES |
dc.contributor.author | Giménez-Romero, David | es_ES |
dc.date.accessioned | 2020-04-06T08:57:32Z | |
dc.date.available | 2020-04-06T08:57:32Z | |
dc.date.issued | 2017 | es_ES |
dc.identifier.issn | 0956-5663 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10251/140249 | |
dc.description.abstract | [EN] An autoantigen piezoelectric sensor to quantify specific circulating autoantibodies in human serum is developed. The sensor consisted on a quartz crystal microbalance with dissipation monitoring (QCM-D) where TRIM21 and TROVE2 autoantigens were covalently immobilized, allowing the selective determination of autoantibodies for diagnosis and prognosis of Systemic Lupus Erythematosus (SLE). The sensitivity of the biosensor, measured as IC50 value, was 1.51 U/mL and 0.32 U/mL, for anti-TRIM21 and anti-TROVE2 circulating autoantibodies, respectively. The sensor is also able to establish a structural interaction fingerprint pattern or profile of circulating autoantibodies, what allows scoring accurately SLE patients. Furthermore, a statistical association of global disease activity with TRIM21-TROVE2 interaction was found (n=130 lupic patient samples, p-value=0.0413). The performances of the biosensor were compared with standard ELISA and multiplex DVD-array high-throughput screening assays, corroborating the viability of piezoelectric biosensor as a cost-effective in vitro assay for the early detection, monitoring or treatment of rare diseases. | es_ES |
dc.description.sponsorship | We acknowledge financial support from the Generalitat Valenciana (GVA-PROMETEOII/2014/040) as well as the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund under award numbers CTQ2013-45875-R and CTQ2013-42914-R. | es_ES |
dc.language | Inglés | es_ES |
dc.publisher | Elsevier | es_ES |
dc.relation.ispartof | Biosensors and Bioelectronics | es_ES |
dc.rights | Reserva de todos los derechos | es_ES |
dc.subject | Systemic Lupus Erythematosus | es_ES |
dc.subject | Diagnosis | es_ES |
dc.subject | Interaction fingerprint | es_ES |
dc.subject | Immunosensor | es_ES |
dc.subject | Quartz crystal microbalance | es_ES |
dc.subject | Dissipation monitoring | es_ES |
dc.subject.classification | QUIMICA ANALITICA | es_ES |
dc.title | Label-free piezoelectric biosensor for prognosis and diagnosis of Systemic Lupus Erythematosus | es_ES |
dc.type | Artículo | es_ES |
dc.identifier.doi | 10.1016/j.bios.2016.11.004 | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//CTQ2013-42914-R/ES/SERODIAGNOSTICO DE ENFERMEDADES AUTOINMUNES A TRAVES DE LA RED IDIOTIPO-ANTIIDIOTIPO. BASES Y APLICACION/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/GVA//PROMETEOII%2F2014%2F040/ES/Estudio de estrategias fisico-químicas para el desarrollo de biosensores interferométricos en soportes interactivos de aplicación en clínica/ | es_ES |
dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//CTQ2013-45875-R/ES/BIOSENSADO EN SOPORTES INTERACTIVOS CON PROPIEDADES INTERFEROMETRICAS PARA APLICACIONES CLINICAS. DEMOSTRACION EN FARMACOGENETICA Y ALERGIAS MEDICAMENTOSAS/ | es_ES |
dc.rights.accessRights | Abierto | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Instituto de Reconocimiento Molecular y Desarrollo Tecnológico - Institut de Reconeixement Molecular i Desenvolupament Tecnològic | es_ES |
dc.contributor.affiliation | Universitat Politècnica de València. Departamento de Química - Departament de Química | es_ES |
dc.description.bibliographicCitation | Do Nascimento, NM.; Juste-Dolz, A.; Grau-García, E.; Roman-Ivorra, JA.; Puchades, R.; Maquieira Catala, A.; Morais, S.... (2017). Label-free piezoelectric biosensor for prognosis and diagnosis of Systemic Lupus Erythematosus. Biosensors and Bioelectronics. 90:166-173. https://doi.org/10.1016/j.bios.2016.11.004 | es_ES |
dc.description.accrualMethod | S | es_ES |
dc.relation.publisherversion | https://doi.org/10.1016/j.bios.2016.11.004 | es_ES |
dc.description.upvformatpinicio | 166 | es_ES |
dc.description.upvformatpfin | 173 | es_ES |
dc.type.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.description.volume | 90 | es_ES |
dc.relation.pasarela | S\321415 | es_ES |
dc.contributor.funder | Generalitat Valenciana | es_ES |
dc.contributor.funder | European Regional Development Fund | es_ES |
dc.contributor.funder | Ministerio de Economía y Competitividad | es_ES |
dc.contributor.funder | Ministerio de Economía, Industria y Competitividad | es_ES |