Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Garcia-Casado, Javier es_ES
dc.contributor.author Ye Lin, Yiyao es_ES
dc.contributor.author Prats-Boluda, Gema es_ES
dc.contributor.author Makeyev, Oleksandr es_ES
dc.date.accessioned 2020-04-17T12:50:33Z
dc.date.available 2020-04-17T12:50:33Z
dc.date.issued 2019-09-01 es_ES
dc.identifier.uri http://hdl.handle.net/10251/140919
dc.description.abstract [EN] Surface Laplacian estimates via concentric ring electrodes (CREs) have proven to enhance spatial resolution compared to conventional disc electrodes, which is of great importance for P-wave analysis. In this study, Laplacian estimates for traditional bipolar configuration (BC), two tripolar configurations with linearly decreasing and increasing inter-ring distances (TCLDIRD and TCLIIRD, respectively), and quadripolar configuration (QC) were obtained from cardiac recordings with pentapolar CREs placed at CMV1 and CMV2 positions. Normalized P-wave amplitude (NAP) was computed to assess the contrast to study atrial activity. Signals were of good quality (20-30 dB). Atrial activity was more emphasized at CMV1 (NAP similar or equal to 0.19-0.24) compared to CMV2 (NAP similar or equal to 0.08-0.10). Enhanced spatial resolution of TCLIIRD and QC resulted in higher NAP values than BC and TCLDIRD. Comparison with simultaneous standard 12-lead ECG proved that Laplacian estimates at CMV1 outperformed all the limb and chest standard leads in the contrast to study P-waves. Clinical recordings with CRE at this position could allow more detailed observation of atrial activity and facilitate the diagnosis of associated pathologies. Furthermore, such recordings would not require additional electrodes on limbs and could be performed wirelessly, so it should also be suitable for ambulatory monitoring, for example, using cardiac Holter monitors. es_ES
dc.description.sponsorship This research was funded by the National Science Foundation (NSF) Division of Human Resource Development (HRD) Tribal Colleges and Universities Program (TCUP), grants number 1622481 and 1914787 to O.M. es_ES
dc.language Inglés es_ES
dc.publisher MDPI AG es_ES
dc.relation.ispartof Sensors es_ES
dc.rights Reconocimiento (by) es_ES
dc.subject Electrocardiography es_ES
dc.subject Biopotentials es_ES
dc.subject Measurement es_ES
dc.subject Wearable sensors es_ES
dc.subject Concentric ring electrodes es_ES
dc.subject Laplacian es_ES
dc.subject Estimation es_ES
dc.subject.classification TECNOLOGIA ELECTRONICA es_ES
dc.title Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.3390/s19173780 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/NSF//1622481/US/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/NSF//1914787/US/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica es_ES
dc.description.bibliographicCitation Garcia-Casado, J.; Ye Lin, Y.; Prats-Boluda, G.; Makeyev, O. (2019). Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes. Sensors. 19(17):1-11. https://doi.org/10.3390/s19173780 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.3390/s19173780 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 11 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 19 es_ES
dc.description.issue 17 es_ES
dc.identifier.eissn 1424-8220 es_ES
dc.relation.pasarela S\396298 es_ES
dc.contributor.funder National Science Foundation, EEUU es_ES
dc.description.references Roth, G. A., Johnson, C., Abajobir, A., Abd-Allah, F., Abera, S. F., Abyu, G., … Alam, K. (2017). Global, Regional, and National Burden of Cardiovascular Diseases for 10 Causes, 1990 to 2015. Journal of the American College of Cardiology, 70(1), 1-25. doi:10.1016/j.jacc.2017.04.052 es_ES
dc.description.references Lopez, A. D., Mathers, C. D., Ezzati, M., Jamison, D. T., & Murray, C. J. (2006). Global and regional burden of disease and risk factors, 2001: systematic analysis of population health data. The Lancet, 367(9524), 1747-1757. doi:10.1016/s0140-6736(06)68770-9 es_ES
dc.description.references Bhatnagar, P., Wickramasinghe, K., Wilkins, E., & Townsend, N. (2016). Trends in the epidemiology of cardiovascular disease in the UK. Heart, 102(24), 1945-1952. doi:10.1136/heartjnl-2016-309573 es_ES
dc.description.references https://healthmetrics.heart.org/cardiovascular-disease-a-costly-burden/ es_ES
dc.description.references Leal, J., Luengo-Fernández, R., Gray, A., Petersen, S., & Rayner, M. (2006). Economic burden of cardiovascular diseases in the enlarged European Union. European Heart Journal, 27(13), 1610-1619. doi:10.1093/eurheartj/ehi733 es_ES
dc.description.references Wang, Y., Cuculich, P. S., Zhang, J., Desouza, K. A., Vijayakumar, R., Chen, J., … Rudy, Y. (2011). Noninvasive Electroanatomic Mapping of Human Ventricular Arrhythmias with Electrocardiographic Imaging. Science Translational Medicine, 3(98), 98ra84-98ra84. doi:10.1126/scitranslmed.3002152 es_ES
dc.description.references SippensGroenewegen, A., Peeters, H. A. P., Jessurun, E. R., Linnenbank, A. C., Robles de Medina, E. O., Lesh, M. D., & van Hemel, N. M. (1998). Body Surface Mapping During Pacing at Multiple Sites in the Human Atrium. Circulation, 97(4), 369-380. doi:10.1161/01.cir.97.4.369 es_ES
dc.description.references Kornreich, F., MacLeod, R. S., & Lux, R. L. (2008). Supplemented standard 12-lead electrocardiogram for optimal diagnosis and reconstruction of significant body surface map patterns. Journal of Electrocardiology, 41(3), 251-256. doi:10.1016/j.jelectrocard.2008.02.011 es_ES
dc.description.references Fereniec, M., Stix, G., Kania, M., Mroczka, T., & Maniewski, R. (2013). An Analysis of the U-Wave and Its Relation to the T-Wave in Body Surface Potential Maps for Healthy Subjects and MI Patients. Annals of Noninvasive Electrocardiology, 19(2), 145-156. doi:10.1111/anec.12110 es_ES
dc.description.references Lian, J., Li, G., Cheng, J., Avitall, B., & He, B. (2002). Body surface Laplacian mapping of atrial depolarization in healthy human subjects. Medical & Biological Engineering & Computing, 40(6), 650-659. doi:10.1007/bf02345304 es_ES
dc.description.references Wu, D., Tsai, H. C., & He, B. (1999). On the Estimation of the Laplacian Electrocardiogram during Ventricular Activation. Annals of Biomedical Engineering, 27(6), 731-745. doi:10.1114/1.224 es_ES
dc.description.references He, B., & Cohen, R. J. (1992). Body surface Laplacian mapping of cardiac electrical activity. The American Journal of Cardiology, 70(20), 1617-1620. doi:10.1016/0002-9149(92)90471-a es_ES
dc.description.references He, B., & Cohen, R. J. (1992). Body surface Laplacian ECG mapping. IEEE Transactions on Biomedical Engineering, 39(11), 1179-1191. doi:10.1109/10.168684 es_ES
dc.description.references He, B., & Cohen, R. J. (1995). Body Surface Laplacian Electrocardiographic Mapping−A Review. Critical Reviews in Biomedical Engineering, 23(5-6), 475-510. doi:10.1615/critrevbiomedeng.v23.i5-6.30 es_ES
dc.description.references UMETANI, K., OKAMOTO, Y., MASHIMA, S., ONO, K., HOSAKA, H., & HE, B. (1998). Body Surface Laplacian Mapping in Patients with Left or Right Ventricular Bundle Branch Block. Pacing and Clinical Electrophysiology, 21(11), 2043-2054. doi:10.1111/j.1540-8159.1998.tb01122.x es_ES
dc.description.references Bin He, Guanglin Li, & Jie Lian. (2002). A spline Laplacian ECG estimator in a realistic geometry volume conductor. IEEE Transactions on Biomedical Engineering, 49(2), 110-117. doi:10.1109/10.979350 es_ES
dc.description.references Besio, G., Koka, K., Aakula, R., & Weizhong Dai. (2006). Tri-polar concentric ring electrode development for Laplacian electroencephalography. IEEE Transactions on Biomedical Engineering, 53(5), 926-933. doi:10.1109/tbme.2005.863887 es_ES
dc.description.references Besio, W., Aakula, R., Koka, K., & Dai, W. (2006). Development of a Tri-polar Concentric Ring Electrode for Acquiring Accurate Laplacian Body Surface Potentials. Annals of Biomedical Engineering, 34(3), 426-435. doi:10.1007/s10439-005-9054-8 es_ES
dc.description.references Besio, W., & Chen, T. (2007). Tripolar Laplacian electrocardiogram and moment of activation isochronal mapping. Physiological Measurement, 28(5), 515-529. doi:10.1088/0967-3334/28/5/006 es_ES
dc.description.references Prats-Boluda, G., Garcia-Casado, J., Martinez-de-Juan, J. L., & Ye-Lin, Y. (2011). Active concentric ring electrode for non-invasive detection of intestinal myoelectric signals. Medical Engineering & Physics, 33(4), 446-455. doi:10.1016/j.medengphy.2010.11.009 es_ES
dc.description.references Prats-Boluda, G., Ye-Lin, Y., Bueno-Barrachina, J., Rodriguez de Sanabria, R., & Garcia-Casado, J. (2016). Towards the clinical use of concentric electrodes in ECG recordings: influence of ring dimensions and electrode position. Measurement Science and Technology, 27(2), 025705. doi:10.1088/0957-0233/27/2/025705 es_ES
dc.description.references Zena-Giménez, V., Garcia-Casado, J., Ye-Lin, Y., Garcia-Breijo, E., & Prats-Boluda, G. (2018). A Flexible Multiring Concentric Electrode for Non-Invasive Identification of Intestinal Slow Waves. Sensors, 18(2), 396. doi:10.3390/s18020396 es_ES
dc.description.references Ye-Lin, Y., Alberola-Rubio, J., Prats-boluda, G., Perales, A., Desantes, D., & Garcia-Casado, J. (2014). Feasibility and Analysis of Bipolar Concentric Recording of Electrohysterogram with Flexible Active Electrode. Annals of Biomedical Engineering, 43(4), 968-976. doi:10.1007/s10439-014-1130-5 es_ES
dc.description.references Wang, K., Parekh, U., Pailla, T., Garudadri, H., Gilja, V., & Ng, T. N. (2017). Stretchable Dry Electrodes with Concentric Ring Geometry for Enhancing Spatial Resolution in Electrophysiology. Advanced Healthcare Materials, 6(19), 1700552. doi:10.1002/adhm.201700552 es_ES
dc.description.references Lidón-Roger, J., Prats-Boluda, G., Ye-Lin, Y., Garcia-Casado, J., & Garcia-Breijo, E. (2018). Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology. Sensors, 18(1), 300. doi:10.3390/s18010300 es_ES
dc.description.references Makeyev, O., Ding, Q., & Besio, W. G. (2016). Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes. Measurement, 80, 44-52. doi:10.1016/j.measurement.2015.11.017 es_ES
dc.description.references Makeyev, O., & Besio, W. (2016). Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes. Sensors, 16(6), 858. doi:10.3390/s16060858 es_ES
dc.description.references Makeyev, O. (2018). Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation. BioMedical Engineering OnLine, 17(1). doi:10.1186/s12938-018-0549-6 es_ES
dc.description.references Ye-Lin, Y., Bueno-Barrachina, J. M., Prats-boluda, G., Rodriguez de Sanabria, R., & Garcia-Casado, J. (2017). Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode. Measurement, 97, 195-202. doi:10.1016/j.measurement.2016.11.009 es_ES
dc.description.references Prats-Boluda, G., Ye-Lin, Y., Pradas-Novella, F., Garcia-Breijo, E., & Garcia-Casado, J. (2018). Textile Concentric Ring Electrodes: Influence of Position and Electrode Size on Cardiac Activity Monitoring. Journal of Sensors, 2018, 1-9. doi:10.1155/2018/7290867 es_ES
dc.description.references Huiskamp, G. (1991). Difference formulas for the surface Laplacian on a triangulated surface. Journal of Computational Physics, 95(2), 477-496. doi:10.1016/0021-9991(91)90286-t es_ES
dc.description.references Hamilton, P. S., & Tompkins, W. J. (1986). Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database. IEEE Transactions on Biomedical Engineering, BME-33(12), 1157-1165. doi:10.1109/tbme.1986.325695 es_ES
dc.description.references Koka, K., & Besio, W. G. (2007). Improvement of spatial selectivity and decrease of mutual information of tri-polar concentric ring electrodes. Journal of Neuroscience Methods, 165(2), 216-222. doi:10.1016/j.jneumeth.2007.06.007 es_ES
dc.description.references Prats-Boluda, G., Ye-Lin, Y., Bueno Barrachina, J. M., Senent, E., Rodriguez de Sanabria, R., & Garcia-Casado, J. (2015). Development of a portable wireless system for bipolar concentric ECG recording. Measurement Science and Technology, 26(7), 075102. doi:10.1088/0957-0233/26/7/075102 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)