Experimental evaluation of the inter-stage conditions of a two-stage refrigeration cycle using a compound compressor

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Experimental evaluation of the inter-stage conditions of a two-stage refrigeration cycle using a compound compressor

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Torrella Alcaraz, Enrique es_ES
dc.contributor.author Llopis, R. es_ES
dc.contributor.author Cabello, R. es_ES
dc.date.accessioned 2020-04-17T12:50:55Z
dc.date.available 2020-04-17T12:50:55Z
dc.date.issued 2009 es_ES
dc.identifier.issn 0140-7007 es_ES
dc.identifier.uri http://hdl.handle.net/10251/140933
dc.description.abstract [EN] The aim of the present paper is to detail an analysis, based on experimental data, of the inter-stage working conditions of a two-stage vapour compression facility equipped with a compound compressor, which operates with the most usual inter-stage configurations (two-stage with direct liquid injection and two-stage with subcooler) in medium- and low-capacity commercial refrigeration applications. The experimental analysis is performed in an evaporating temperature range between -36 and -20 degrees C, and in a condensing temperature range between 30 and 47 degrees C, using one of the fluids most widely-used in Europe for low-temperature applications, the R-404a. The inter-stage working temperature/pressure obtained in the tests has been contrasted with the two usual criterion of the optimum working conditions definition: the arithmetical mean of the refrigerant condensing and evaporating temperatures and the criterion of equal pressure ratios in both stages. This paper presents the differences and affinities with the criterion and analyses the influence of the intermediate systems (direct liquid injection and subcooler) on the inter-stage operating conditions. es_ES
dc.description.sponsorship The authors are indebted to the Generalitat Valenciana for partial support under project GV05/091. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof International Journal of Refrigeration es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Refrigerated system es_ES
dc.subject Two-stage system es_ES
dc.subject Compression system es_ES
dc.subject R404A es_ES
dc.subject Experiment es_ES
dc.subject Performance es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.title Experimental evaluation of the inter-stage conditions of a two-stage refrigeration cycle using a compound compressor es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.ijrefrig.2008.05.006 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//GV05%2F091/ es_ES
dc.rights.accessRights Cerrado es_ES
dc.description.bibliographicCitation Torrella Alcaraz, E.; Llopis, R.; Cabello, R. (2009). Experimental evaluation of the inter-stage conditions of a two-stage refrigeration cycle using a compound compressor. International Journal of Refrigeration. 32(2):307-315. https://doi.org/10.1016/j.ijrefrig.2008.05.006 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.ijrefrig.2008.05.006 es_ES
dc.description.upvformatpinicio 307 es_ES
dc.description.upvformatpfin 315 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 32 es_ES
dc.description.issue 2 es_ES
dc.relation.pasarela S\33649 es_ES
dc.contributor.funder Generalitat Valenciana es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem