- -

Commentary on 'Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects'

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Commentary on 'Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects'

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Rossetti, Paolo es_ES
dc.contributor.author Vehí, Josep es_ES
dc.contributor.author Revert Tomás, Ana es_ES
dc.contributor.author Calm, Remei es_ES
dc.contributor.author Bondía Company, Jorge es_ES
dc.date.accessioned 2020-04-17T12:52:34Z
dc.date.available 2020-04-17T12:52:34Z
dc.date.issued 2012-03-01 es_ES
dc.identifier.issn 1932-2968 es_ES
dc.identifier.uri http://hdl.handle.net/10251/140985
dc.description.abstract [EN] Since the early 2000s, there has been an exponentially increasing development of new diabetes-applied technology such as continuous glucose monitoring, bolus calculators, and "smart" pumps, with the expectation of partially overcoming clinical inertia and low patient compliance. However, its long-term efficacy in glucose control has not been unequivocally proven. In this issue of Journal of Diabetes Science and Technology, Sussman and colleagues evaluated a tool for the calculation of the prandial insulin dose. A total of 205 insulin-treated patients were asked to compute a bolus dose in two simulated conditions either manually or with the bolus calculator built into the FreeStyle InsuLinx meter, revealing the high frequency of wrong calculations when performed manually. Although the clinical impact of this study is limited, it highlights the potential implications of low diabetes-related numeracy in poor glycemic control. Educational programs aiming to increase patients' empowerment and caregivers' knowledge are needed in order to get full benefit of the technology. es_ES
dc.language Inglés es_ES
dc.publisher SAGE Publications es_ES
dc.relation.ispartof Journal of Diabetes Science and Technology es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Blood glucose monitoring es_ES
dc.subject Bolus calculator es_ES
dc.subject Education es_ES
dc.subject Numeracy es_ES
dc.subject.classification INGENIERIA DE SISTEMAS Y AUTOMATICA es_ES
dc.title Commentary on 'Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects' es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1177/193229681200600219 es_ES
dc.rights.accessRights Cerrado es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería de Sistemas y Automática - Departament d'Enginyeria de Sistemes i Automàtica es_ES
dc.description.bibliographicCitation Rossetti, P.; Vehí, J.; Revert Tomás, A.; Calm, R.; Bondía Company, J. (2012). Commentary on 'Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects'. Journal of Diabetes Science and Technology. 6(2):345-347. https://doi.org/10.1177/193229681200600219 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1177/193229681200600219 es_ES
dc.description.upvformatpinicio 345 es_ES
dc.description.upvformatpfin 347 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 6 es_ES
dc.description.issue 2 es_ES
dc.identifier.pmid 22538145 es_ES
dc.relation.pasarela S\240853 es_ES
dc.description.references Phillips, L. S., Branch, W. T., Cook, C. B., Doyle, J. P., El-Kebbi, I. M., Gallina, D. L., … Barnes, C. S. (2001). Clinical Inertia. Annals of Internal Medicine, 135(9), 825. doi:10.7326/0003-4819-135-9-200111060-00012 es_ES
dc.description.references Cavanaugh, K. L. (2011). Health literacy in diabetes care: explanation, evidence and equipment. Diabetes Management, 1(2), 191-199. doi:10.2217/dmt.11.5 es_ES
dc.description.references Nam, S., Chesla, C., Stotts, N. A., Kroon, L., & Janson, S. L. (2011). Barriers to diabetes management: Patient and provider factors. Diabetes Research and Clinical Practice, 93(1), 1-9. doi:10.1016/j.diabres.2011.02.002 es_ES
dc.description.references Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012). Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database of Systematic Reviews. doi:10.1002/14651858.cd008101.pub2 es_ES
dc.description.references Cavanaugh, K., Wallston, K. A., Gebretsadik, T., Shintani, A., Huizinga, M. M., Davis, D., … Rothman, R. L. (2009). Addressing Literacy and Numeracy to Improve Diabetes Care: Two randomized controlled trials. Diabetes Care, 32(12), 2149-2155. doi:10.2337/dc09-0563 es_ES
dc.description.references Klupa, T., Benbenek-Klupa, T., Malecki, M., Szalecki, M., & Sieradzki, J. (2008). Clinical Usefulness of a Bolus Calculator in Maintaining Normoglycaemia in Active Professional Patients with Type 1 Diabetes Treated with Continuous Subcutaneous Insulin Infusion. Journal of International Medical Research, 36(5), 1112-1116. doi:10.1177/147323000803600531 es_ES
dc.description.references Sussman, A., Taylor, E. J., Patel, M., Ward, J., Alva, S., Lawrence, A., & Ng, R. (2012). Performance of a Glucose Meter with a Built-in Automated Bolus Calculator versus Manual Bolus Calculation in Insulin-Using Subjects. Journal of Diabetes Science and Technology, 6(2), 339-344. doi:10.1177/193229681200600218 es_ES
dc.description.references Reyna, V. F., Nelson, W. L., Han, P. K., & Dieckmann, N. F. (2009). How numeracy influences risk comprehension and medical decision making. Psychological Bulletin, 135(6), 943-973. doi:10.1037/a0017327 es_ES
dc.description.references Cavanaugh, K., Huizinga, M. M., Wallston, K. A., Gebretsadik, T., Shintani, A., Davis, D., … Rothman, R. L. (2008). Association of Numeracy and Diabetes Control. Annals of Internal Medicine, 148(10), 737. doi:10.7326/0003-4819-148-10-200805200-00006 es_ES
dc.description.references Gross, T. M., Kayne, D., King, A., Rother, C., & Juth, S. (2003). A Bolus Calculator Is an Effective Means of Controlling Postprandial Glycemia in Patients on Insulin Pump Therapy. Diabetes Technology & Therapeutics, 5(3), 365-369. doi:10.1089/152091503765691848 es_ES
dc.description.references Shashaj, B., Busetto, E., & Sulli, N. (2008). Benefits of a bolus calculator in pre- and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII). Diabetic Medicine, 25(9), 1036-1042. doi:10.1111/j.1464-5491.2008.02549.x es_ES
dc.description.references Walsh, J., Roberts, R., & Bailey, T. (2010). Guidelines for Insulin Dosing in Continuous Subcutaneous Insulin Infusion Using New Formulas from a Retrospective Study of Individuals with Optimal Glucose Levels. Journal of Diabetes Science and Technology, 4(5), 1174-1181. doi:10.1177/193229681000400516 es_ES
dc.description.references Walsh, J., Roberts, R., & Bailey, T. (2011). Guidelines for Optimal Bolus Calculator Settings in Adults. Journal of Diabetes Science and Technology, 5(1), 129-135. doi:10.1177/193229681100500118 es_ES
dc.description.references Zisser, H., Robinson, L., Bevier, W., Dassau, E., Ellingsen, C., Doyle, F. J., & Jovanovic, L. (2008). Bolus Calculator: A Review of Four «Smart» Insulin Pumps. Diabetes Technology & Therapeutics, 10(6), 441-444. doi:10.1089/dia.2007.0284 es_ES
dc.description.references Klupa, T., Skupien, J., Cyganek, K., Katra, B., Sieradzki, J., & Malecki, M. T. (2010). The dual-wave bolus feature in type 1 diabetes adult users of insulin pumps. Acta Diabetologica, 48(1), 11-14. doi:10.1007/s00592-009-0173-9 es_ES
dc.description.references Chase, H. P., Saib, S. Z., MacKenzie, T., Hansen, M. M., & Garg, S. K. (2002). Post-prandial glucose excursions following four methods of bolus insulin administration in subjects with Type 1 diabetes. Diabetic Medicine, 19(4), 317-321. doi:10.1046/j.1464-5491.2002.00685.x es_ES
dc.description.references Jones, S. M., Quarry, J. L., Caldwell-McMillan, M., Mauger, D. T., & Gabbay, R. A. (2005). Optimal Insulin Pump Dosing and Postprandial Glycemia Following a Pizza Meal Using the Continuous Glucose Monitoring System. Diabetes Technology & Therapeutics, 7(2), 233-240. doi:10.1089/dia.2005.7.233 es_ES
dc.description.references Pańkowska, E., Błazik, M., & Groele, L. (2012). Does the Fat-Protein Meal Increase Postprandial Glucose Level in Type 1 Diabetes Patients on Insulin Pump: The Conclusion of a Randomized Study. Diabetes Technology & Therapeutics, 14(1), 16-22. doi:10.1089/dia.2011.0083 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem