Comparison of the performance of a vapor-injection scroll compressor and a two-stage scroll compressor working with high pressure ratios

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Comparison of the performance of a vapor-injection scroll compressor and a two-stage scroll compressor working with high pressure ratios

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Tello-Oquendo, Fernando M. es_ES
dc.contributor.author Navarro-Peris, Emilio es_ES
dc.contributor.author Gonzálvez-Maciá, José es_ES
dc.date.accessioned 2020-04-30T06:21:15Z
dc.date.available 2020-04-30T06:21:15Z
dc.date.issued 2019-09 es_ES
dc.identifier.issn 1359-4311 es_ES
dc.identifier.uri http://hdl.handle.net/10251/142038
dc.description.abstract [EN] This paper presents a comparative analysis of the performance of a vapor-injection scroll compressor (SCVI) and a two-stage scroll compressor (TSSC) working with high pressure ratios in heat pump applications. Semi-empirical models of the compressors are implemented. The models are adjusted with experimental data obtained in a calorimetric test bench. The optimum displacement ratio (DR) is analyzed considering two criteria, COP maximization, and discharge temperature minimization. Once defined the optimum DR, a systematic comparison of the compressors is performed in terms of compressor efficiencies, heating capacity, COP, and discharge temperature. Finally, the intermediate pressure is optimized for a high-temperature water heating application, taking into account heat sink of finite capacity. Results show that the optimum DR of TSSC is around 0.58 and the COP is 6% larger than that the SCVI at the nominal point. Considering a wide range of operating conditions, the SCVI presents better efficiency and COP for pressure ratios below 5. For higher-pressure ratios, the TSSC presents better performance and achieves lower discharge temperature. The heating capacity of the TSSC can be improved by 7% by varying the swept volume of the high-stage compressor compared with the SCVI, with a minimum effect on the COP and on the discharge temperature from the optimum conditions. es_ES
dc.description.sponsorship Fernando M. Tello-Oquendo acknowledges the financial support provided by the CONVOCATORIA ABIERTA 2013-SEGUNDA FASE program, which was funded by the SENESCYT (Secretaría de Educación Superior, Ciencia, Tecnología e Innovación) (Grant No. 2015-AR37665) of Ecuador. The authors would like to acknowledge Emerson Commercial and Residential Solutions for the given support to obtain the experimental data of scroll compressors and testing. In addition, the authors acknowledge the Spanish MINISTERIO DE ECONOMIA Y COMPETITIVIDAD , through the project ref-ENE2017-83665-C2-1-P Maximización de la eficiencia y minimización del impacto ambiental de bombas de calor para la descarbonización de la calefacción/ACS en los edificios de consumo casi nulo for the given support. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Applied Thermal Engineering es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Two-stage compression es_ES
dc.subject Scroll compressor es_ES
dc.subject Reciprocating compressor es_ES
dc.subject Vapor-injection es_ES
dc.subject Optimization es_ES
dc.subject Performance comparison es_ES
dc.subject.classification MAQUINAS Y MOTORES TERMICOS es_ES
dc.title Comparison of the performance of a vapor-injection scroll compressor and a two-stage scroll compressor working with high pressure ratios es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.applthermaleng.2019.114023 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/SENESCYT//2015-AR37665/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/ENE2017-83665-C2-1-P/ES/MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION%2FACS EN LOS EDIFICIOS DE CONSUMO CASI NULO/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Termodinámica Aplicada - Departament de Termodinàmica Aplicada es_ES
dc.description.bibliographicCitation Tello-Oquendo, FM.; Navarro-Peris, E.; Gonzálvez-Maciá, J. (2019). Comparison of the performance of a vapor-injection scroll compressor and a two-stage scroll compressor working with high pressure ratios. Applied Thermal Engineering. 160:1-15. https://doi.org/10.1016/j.applthermaleng.2019.114023 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.applthermaleng.2019.114023 es_ES
dc.description.upvformatpinicio 1 es_ES
dc.description.upvformatpfin 15 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 160 es_ES
dc.relation.pasarela S\405667 es_ES
dc.contributor.funder Agencia Estatal de Investigación es_ES
dc.contributor.funder Secretaría de Educación Superior, Ciencia, Tecnología e Innovación, Ecuador es_ES