- -

Rapid method for radiostrontium determination in milk in emergency situations using PS resin

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Rapid method for radiostrontium determination in milk in emergency situations using PS resin

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Sáez-Muñoz, Marina es_ES
dc.contributor.author Bagán, H. es_ES
dc.contributor.author Tarancón, Alex es_ES
dc.contributor.author García, José F. es_ES
dc.contributor.author Ortiz Moragón, Josefina es_ES
dc.contributor.author Martorell Alsina, Sebastián Salvador es_ES
dc.date.accessioned 2020-05-22T03:02:45Z
dc.date.available 2020-05-22T03:02:45Z
dc.date.issued 2018-03 es_ES
dc.identifier.issn 0236-5731 es_ES
dc.identifier.uri http://hdl.handle.net/10251/144093
dc.description.abstract [EN] This study describes a new and rapid procedure for radiostrontium determination in milk samples based on the use of plastic scintillation resins (PS resins). The proposed method reduces the time of analysis by at least 2 h by combining separation and measurement preparation into a single step and optimizing the pre-treatment steps. The method is robust and reproducible, with good total recoveries (65% on average) and a relative bias for total radiostrontium activity (Sr-89 + Sr-90) below 7%. The minimum detectable activity for 100 mL of milk sample measured for 60 min is about 0.34 Bq L-1. The proposed method can quantify radiostrontium content in 5 h, which makes it suitable for use in emergency situations. es_ES
dc.description.sponsorship The authors are grateful to the Spanish Ministerio de Economia y Competitividad (MINECO) for financial support, under CTM2014-02020 and the Catalan Agencia de Gestio d'Ajuts Universitaris i de Recerca (AGAUR) for financial support, under 2014-SGR-1277. We should also like to thank the Universitat Politecnica de Valencia for finantial support under the "Programa propio para la Formacion de Personal Investigador (FPI) de la UniversitatPolitecnica de Valencia - Subprograma 100. es_ES
dc.language Inglés es_ES
dc.publisher Springer-Verlag es_ES
dc.relation.ispartof Journal of Radioanalytical and Nuclear Chemistry es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Plastic scintillation resins es_ES
dc.subject Emergency situations es_ES
dc.subject Radiostrontium es_ES
dc.subject Milk samples es_ES
dc.subject Rapid method es_ES
dc.subject.classification INGENIERIA NUCLEAR es_ES
dc.subject.classification ESTADISTICA E INVESTIGACION OPERATIVA es_ES
dc.title Rapid method for radiostrontium determination in milk in emergency situations using PS resin es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1007/s10967-017-5682-3 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/MINECO//CTM2014-02020/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/Generalitat de Catalunya//2014 SGR 1277/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Química y Nuclear - Departament d'Enginyeria Química i Nuclear es_ES
dc.description.bibliographicCitation Sáez-Muñoz, M.; Bagán, H.; Tarancón, A.; García, JF.; Ortiz Moragón, J.; Martorell Alsina, SS. (2018). Rapid method for radiostrontium determination in milk in emergency situations using PS resin. Journal of Radioanalytical and Nuclear Chemistry. 315(3):543-555. https://doi.org/10.1007/s10967-017-5682-3 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1007/s10967-017-5682-3 es_ES
dc.description.upvformatpinicio 543 es_ES
dc.description.upvformatpfin 555 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 315 es_ES
dc.description.issue 3 es_ES
dc.relation.pasarela S\355801 es_ES
dc.contributor.funder Universitat Politècnica de València es_ES
dc.contributor.funder Ministerio de Economía y Competitividad es_ES
dc.contributor.funder Agencia de Gestión de Ayudas Universitarias y de Investigación es_ES
dc.description.references International Atomic Energy Agency (2015) The fukushima daiichi accident, technical radiological consequences, vol 4. IAEA, Vienna es_ES
dc.description.references International Atomic Energy Agency (2006) Environmental consequences of the chernobyl accident and their remediation: 20 years of experience, Report of the UN Chernobyl forum expert group “environment”, radiological assessment reports Series No. 8, IAEA, Vienna es_ES
dc.description.references Povinec PP, Hirose K, Aoyama M (2013) Fukushima accident: radioactivity impact on the environment. Elsevier, China es_ES
dc.description.references Council Regulation (Euratom) 2016/52 of 15 January 2016 laying down maximum permitted levels of radioactive contamination of food and feed following a nuclear accident or any other case of radiological emergency, and repealing regulation (Euratom) No 3954/87 and commission regulations (Euratom) No 944/89 and (Euratom) No 770/90 es_ES
dc.description.references Vajda N, Kim CK (2010) Determination of radiostrontium isotopes: a review of analytical methodology. Appl Radiat Isot 68:2306–2326 es_ES
dc.description.references Brun S, Bessac S, Uridat D, Boursier B (2002) Rapid method for the determination of radiostrontium in milk. J Radioanal Nucl Chem 253(2):191–197 es_ES
dc.description.references Maxwell SL, Culligan BK (2009) Rapid method for determination of radiostrontium in emergency milk samples. J Radioanal Nucl Chem 279(3):757–760 es_ES
dc.description.references Kabai E, Hornung L, Savkin BT, Poppitz-Spuhler A, Hiersche L (2011) Fast method and ultra fast screening for determination of 90Sr in milk and dairy products. Sci Total Environ 410–411:235–240 es_ES
dc.description.references International Atomic Energy Agency (2013) Rapid simultaneous determination of 89Sr and 90Sr in milk: a procedure using cerenkov and scintillation counting, analytical quality in nuclear applications no. IAEA/AQ/27, IAEA, Vienna es_ES
dc.description.references Bagán H, Tarancón A, Rauret G, García JF (2011) Radiostrontium separation and measurement in a single step using plastic scintillators plus selective extractants application to aqueous sample analysis. Anal Chim Acta 686:50–56 es_ES
dc.description.references Barrera J, Tarancón A, Bagán H, García JF (2016) A new plastic scintillation resin for single-step separation, concentration and measurement of technetium-99. Anal Chim Acta 936:259–266 es_ES
dc.description.references Lluch E, Barrera J, Tarancón A, Bagán H, García JF (2016) Analysis of 210Pb in water samples with plastic scintillation resins. Anal Chim Acta 940:38–45 es_ES
dc.description.references Santiago L, Tarancón A, García JF (2016) Influence of preparation parameters on the synthesis of plastic scintillation microspheres and evaluation of sample preparation. Adv Powder Technol 27(4):1309–1317 es_ES
dc.description.references Savitzky A, Golay MJE (1964) Smoothing and differentiation of data by simplified least-squares procedures. Anal Chem 36:1627–1639 es_ES
dc.description.references Currie LA (1968) Limits for qualitative detection and quantitative determination. Application to radiochemistry. Anal Chem 40(3):586–593 es_ES
dc.description.references UNE 34829:1983, Determination of the calcium content of milk es_ES
dc.description.references ISO 12081:2010, IDF 36:2010, Milk—Determination of calcium content—titrimetric method es_ES
dc.description.references Heckel A, Vogl K (2009) Rapid method for determination of the activity concentrations of 89Sr and 90Sr. Appl Radiat Isot 67:794–796 es_ES
dc.description.references Kabai E, Savkin B, Mehlsam I, Poppitz-Spuhler A (2017) Combined method for the fast determination of pure beta emitting radioisotopes in food samples. J Radioanal Nucl Chem 311:1401–1408 es_ES
dc.description.references Eikenberg J, Beer H, Rüthi M, Zumsteg I, Vetter A (2005) Precise determination of 89Sr and 90Sr/90Y in various matrices: the LSC 3-window approach. LSC2005 Advances in Liquid Scintillation Spectrometry, Radiocarbon, AZ, pp 237–249 es_ES
dc.description.references Kim CK, Al-Hamwi A, Toervenyi A, Kis-Benedek G, Sansone U (2009) Validation of rapid method for the determination of radiostrontium in milk. Appl Radiat Isot 67:786–793 es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem