- -

Smartphone-based photogrammetric 3D modelling assessment by comparison with radiological medical imaging for cranial deformation analysis

RiuNet: Repositorio Institucional de la Universidad Politécnica de Valencia

Compartir/Enviar a

Citas

Estadísticas

  • Estadisticas de Uso

Smartphone-based photogrammetric 3D modelling assessment by comparison with radiological medical imaging for cranial deformation analysis

Mostrar el registro sencillo del ítem

Ficheros en el ítem

dc.contributor.author Barbero-García, Inés es_ES
dc.contributor.author Lerma, José Luis es_ES
dc.contributor.author Miranda, Pablo es_ES
dc.contributor.author Marqués-Mateu, Ángel es_ES
dc.date.accessioned 2020-06-06T03:32:26Z
dc.date.available 2020-06-06T03:32:26Z
dc.date.issued 2019-01 es_ES
dc.identifier.issn 0263-2241 es_ES
dc.identifier.uri http://hdl.handle.net/10251/145542
dc.description.abstract [EN] Cranial deformation in infants is a common problem in paediatric consultations. The most accurate medical diagnostic imaging methodologies are Computed Tomography (CT) and Magnetic Resonance Image (MRI). However, these radiological imaging technologies involve high costs and are invasive, especially for infants. Therefore, they are only used for severe cases, while milder cases are evaluated using less precise methodologies, such as callipers or measure tapes. The use of smartphone-based photogrammetric 3D models has been presented as a possible alternative to extracting accurate and complete external information in a low-cost, non-invasive manner but its accuracy is still to be tested. In this study, photogrammetric and radiological cranial 3D models have been obtained for a set of 10 patients. In order to compare them, the distances between model surfaces have been calculated. Results show an overestimation of the photogrammetric models up to 3.2 mm due to both hair and usage of caps. However, differences in shape, given by the standard deviation of the distances are below 1.5 mm for every patient. The accuracy of low-cost smartphone-based photogrammetric models has been found to be comparable to medical diagnostic imaging methodologies used for cranial deformation analysis. (C) 2018 Elsevier Ltd. All rights reserved. es_ES
dc.description.sponsorship This study was supported by Conselleria d Educació of the Generalitat Valenciana and the European Social Fund under the grant number ACIF/2017/056. The authors also acknowledge the partial support from the 2017 Subprogram B No. B03 (Acronym HEAD3D++) to the development of coordinated actions between the Universitat Politècnica de València and the Hospital Universitari i Politècnic/Instituto de Investigación Sanitaria La Fe. es_ES
dc.language Inglés es_ES
dc.publisher Elsevier es_ES
dc.relation.ispartof Measurement es_ES
dc.rights Reserva de todos los derechos es_ES
dc.subject Computed tomography es_ES
dc.subject Evaluation es_ES
dc.subject Magnetic resonance imaging es_ES
dc.subject Structure from motion es_ES
dc.subject.classification INGENIERIA CARTOGRAFICA, GEODESIA Y FOTOGRAMETRIA es_ES
dc.title Smartphone-based photogrammetric 3D modelling assessment by comparison with radiological medical imaging for cranial deformation analysis es_ES
dc.type Artículo es_ES
dc.identifier.doi 10.1016/j.measurement.2018.08.059 es_ES
dc.relation.projectID info:eu-repo/grantAgreement/GVA//ACIF%2F2017%2F056/ es_ES
dc.relation.projectID info:eu-repo/grantAgreement/UPV//UPV-FE-2017-B03/ES/Fotogrametría de bajo coste para monitorizar la deformación craneal/ es_ES
dc.rights.accessRights Abierto es_ES
dc.contributor.affiliation Universitat Politècnica de València. Departamento de Ingeniería Cartográfica Geodesia y Fotogrametría - Departament d'Enginyeria Cartogràfica, Geodèsia i Fotogrametria es_ES
dc.description.bibliographicCitation Barbero-García, I.; Lerma, JL.; Miranda, P.; Marqués-Mateu, Á. (2019). Smartphone-based photogrammetric 3D modelling assessment by comparison with radiological medical imaging for cranial deformation analysis. Measurement. 131:372-379. https://doi.org/10.1016/j.measurement.2018.08.059 es_ES
dc.description.accrualMethod S es_ES
dc.relation.publisherversion https://doi.org/10.1016/j.measurement.2018.08.059 es_ES
dc.description.upvformatpinicio 372 es_ES
dc.description.upvformatpfin 379 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion es_ES
dc.description.volume 131 es_ES
dc.relation.pasarela S\367987 es_ES
dc.contributor.funder European Social Fund es_ES
dc.contributor.funder Generalitat Valenciana es_ES
dc.contributor.funder Universitat Politècnica de València es_ES
dc.contributor.funder Instituto de Investigación Sanitaria La Fe es_ES


Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem